The Eaton Tripp Lite Series 1.5kW Single-Phase Local Metered PDU is a premium power distribution unit designed specifically for efficient and effective power management in data centers, server rooms, and any rack-mounted environments. This innovative PDU not only provides robust power distribution but also features real-time monitoring capabilities that help prevent circuit overloads while ensuring optimal performance of your IT infrastructure. With its durable construction and user-friendly design, the Eaton Tripp Lite PDU is an essential tool for any modern IT setup.
- Real-Time Monitoring: The built-in two-digit current meter provides continuous monitoring of load levels in amps, helping to prevent circuit overloads as you add more equipment to your setup.
- High Capacity: With a substantial capacity of 1.5kW at 120V and 15A, this PDU can efficiently power multiple devices at the same time, making it perfect for high-density applications.
- Versatile Outlet Configuration: Equipped with 13 NEMA 5-15R outlets (1 front and 12 rear), this PDU offers ample connectivity, allowing you to plug in all necessary equipment with ease.
- Durable and Secure Design: The all-metal housing not only ensures durability but also includes mounting accessories for a secure rack-mount installation, safeguarding your investment against wear and tear.
- Flexible Power Input: The PDU features a NEMA 5-15P input with a 6 ft. (1.83 m) cord, allowing flexibility in connecting to various power sources, including UPS systems, generators, or mains input power.
Technical Details
- Product Type: Metered PDU
- Input Voltage: 100-127V
- Input Current: 15A
- Total Outlets: 13 NEMA 5-15R
- Input Connector: NEMA 5-15P
- Cord Length: 6 ft. (1.83 m)
- Rack Size: 1U
- Construction: Rugged all-metal housing
How to Install
Installing the Eaton Tripp Lite Series 1.5kW Single-Phase Local Metered PDU is a straightforward process:
- Unbox the PDU and review the included components and mounting accessories.
- Choose a suitable rack location for installation, ensuring there is adequate space for airflow and accessibility.
- Using the provided mounting accessories, securely attach the PDU to the rack.
- Connect the NEMA 5-15P plug to your chosen power source, such as a UPS, generator, or mains outlet.
- Plug your devices into the available NEMA 5-15R outlets, ensuring all connections are secure.
- Turn on the power source and monitor the current levels via the built-in digital current meter.
Frequently Asked Questions
- What is the maximum load this PDU can support? The Eaton Tripp Lite PDU supports a maximum load of 1.5kW at 120V with an input current of 15A.
- Can I mount this PDU in any standard rack? Yes, the PDU is designed for 1U rackmount installation and can be securely mounted in any standard rack.
- How can I monitor the load levels? The PDU features a built-in two-digit current meter that displays real-time load levels in amps, allowing for easy monitoring of power consumption.
- Is it compatible with UPS systems? Absolutely! This PDU can be connected to any protected UPS, generator, or mains input power source for optimal performance.
- What should I do if I exceed the maximum load? If you exceed the maximum load, the meter will indicate high current levels. It is advisable to disconnect some devices or redistribute power loads to prevent circuit overload.