Description
The Tripp Lite by Eaton 3.7kW Single-Phase Local Metered PDU is a top-of-the-line power distribution unit designed for robust performance and reliable operation. This advanced Metered PDU offers real-time local reporting of load levels in amps, making it an essential component for any data center or network operation. With its built-in digital display, users can easily monitor load levels, preventing overloads as additional equipment is added. The rugged all-metal housing and secure rackmount installation ensure durability and ease of use.
- Real-Time Load Monitoring: The built-in digital display provides immediate feedback on load levels in amps, allowing users to keep a close eye on their power consumption and prevent overload situations.
- Versatile Power Distribution: Featuring a total of 38 output receptacles (32 C13 and 6 C19), this PDU enables multiple devices to be powered simultaneously, making it ideal for both small and large setups.
- Robust Design: The PDU is constructed with high-quality all-metal housing, ensuring longevity and reliability even in the most demanding environments.
- Easy Installation: The included mounting accessories facilitate a secure rackmount installation, allowing for straightforward setup and configuration.
- Flexible Power Input: The device comes equipped with a 10ft / 3m input cable featuring an IEC309 Blue 16A connection, making it versatile enough for various power sources including UPS, generators, or mains input power.
Technical Details of Product
- Power Rating: 3.7kW
- Phase: Single-Phase
- Voltage: 208/230V
- Input Connection: IEC309 16A Blue
- Output Receptacles: 32 x C13, 6 x C19
- Meter Type: Two-digit meter reports output current in amps
- Height: 0U (rackmount compatible)
- Length: 63.75 in / 162 cm
- Input Cable Length: 10ft / 3m
How to Install
Installing the Tripp Lite by Eaton 3.7kW Single-Phase Local Metered PDU is simple and straightforward. Follow these steps for a seamless setup:
- Unpack the PDU and ensure all included mounting accessories are present.
- Identify the rack space where you wish to install the PDU. Ensure it is compatible with the PDU's dimensions (0U vertical configuration).
- Using the provided mounting brackets, securely attach the PDU to your rack.
- Connect the 10ft / 3m input cable to your power source (UPS, generator, or mains input).
- Plug in your devices to the C13 and C19 outlets as needed.
- Power on the PDU and check the digital display for load level visibility.
Frequently Asked Questions
-
What is the maximum load capacity of the PDU?
The PDU has a maximum load capacity of 3.7kW. -
Can this PDU be mounted in any standard server rack?
Yes, the PDU is designed for 0U vertical mounting, making it suitable for most standard server racks. -
What type of devices can I connect to this PDU?
You can connect a variety of devices, including servers, networking equipment, and other data center components that are compatible with C13 and C19 outlets. -
Is the PDU suitable for outdoor use?
No, the Tripp Lite Metered PDU is designed for indoor use only. -
Does the PDU come with a warranty?
Yes, Tripp Lite typically offers a limited warranty on their PDUs; please check the product specifications or the manufacturer's website for details.