{"product_id":"apc-ap8958na3-switched-rack-pdu-0u-l6-20p-7-c13-1-c19-200-208-230v-20a","title":"Apc Ap8958Na3 Switched Rack Pdu 0U L6 20P 7 C13 1 C19 200 208 230V 20A","description":"\u003cdiv\u003e\n\u003cp\u003e\u003cb\u003eAPC AP8958NA3 Switched Rack PDU\u003c\/b\u003e is engineered to deliver dependable, granular power distribution for demanding data centers, server rooms, and edge environments. This 0U, 19-inch rack-mountable switched PDU combines robust protection with advanced manageability, giving you outlet-level control, intelligent sequencing, and real-time monitoring. Designed to support a mix of servers, switches, storage arrays, and networking gear, the AP8958NA3 helps optimize uptime, reduce energy waste, and simplify maintenance by turning power management into a proactive, data-driven discipline.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cb\u003eRemote outlet-level control and programmable sequencing:\u003c\/b\u003e Take charge of your rack’s power topology with per-outlet on\/off capabilities and sequenced startup\/shutdown. Power-cycle individual devices without affecting others, enabling safe maintenance windows and orderly boot sequences for dense equipment stacks. This minimizes downtime during firmware updates, troubleshooting, or hardware changes and helps prevent inrush currents and startup conflicts.\u003c\/li\u003e \u003c\/ul\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eAdvanced load monitoring and real-time analytics:\u003c\/b\u003e Gain visibility into energy use with per-outlet metrics and a holistic load view. Track current, voltage, power (kW), and power factor across outlets to identify overload risks, optimize capacity planning, and reduce cooling demands. Proactive analytics help you spot aging hardware early, prevent nuisance trips, and maintain peak performance for critical workloads.\u003c\/li\u003e \u003c\/ul\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eCentralized manageability and security:\u003c\/b\u003e APC Switched Rack PDUs are designed for secure access and centralized control. Role-based permissions, strong authentication options, and seamless integration with existing management systems (such as SNMP and standard DCIM tools) allow you to monitor and manage power without compromising security. Audit trails document who changed settings and when, supporting compliance and governance needs.\u003c\/li\u003e \u003c\/ul\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eHigh-density, scalable rack design:\u003c\/b\u003e The compact, rugged form factor fits a variety of rack configurations while providing multiple outlets in a small footprint. With a 0U profile, it preserves valuable rack space while delivering robust power distribution for dense equipment layouts. The modular design supports data centers, server rooms, and edge deployments that demand scalable, reliable power management.\u003c\/li\u003e \u003c\/ul\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eReliability and protection you can trust:\u003c\/b\u003e Built with industry-leading safeguards—overload protection, short-circuit protection, and thermal protection—these PDUs help prevent device damage and downtime. The PDU focuses on long-term reliability, straightforward installation, intuitive configuration, and easy maintenance so your power distribution stays stable even under demanding conditions.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Details of APC AP8958NA3 Switched Rack PDU\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eModel:\u003c\/b\u003e APC AP8958NA3 Switched Rack PDU\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eForm factor:\u003c\/b\u003e 0U, 19-inch rack-mountable\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eInput:\u003c\/b\u003e L6-20P, 20A, 200–230V (typical data-center power range)\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eOutlets:\u003c\/b\u003e 7 x C13 outlets and 1 x C19 outlet (configurable per-outlet control)\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eManagement:\u003c\/b\u003e Remote monitoring with per-outlet metrics; programmable outlet sequencing; SNMP and DCIM integration options\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eProtection:\u003c\/b\u003e Overload protection, short-circuit protection, thermal safeguards\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eSecurity:\u003c\/b\u003e Role-based access control and audit trails for configuration changes\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eVoltage range supported:\u003c\/b\u003e 200–230 VAC\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eColor\/finish:\u003c\/b\u003e Standard rack-mount finish suitable for data-center environments\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eMounting:\u003c\/b\u003e 19\" rack-mounted with zero-U footprint to maximize rack density\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eHow to install APC AP8958NA3 Switched Rack PDU\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003ePlan and prepare:\u003c\/b\u003e Identify the rack location, confirm a suitable 200–230V power source, and ensure the rack rails are properly installed. Verify that there is adequate clearance for heat dissipation and for cabling to the outlets.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eMount the PDU:\u003c\/b\u003e With the rack power off, slide the AP8958NA3 into the 19\" rack space and secure it using the provided hardware. The 0U form factor preserves vertical space, enabling you to maximize the number of devices powered from a single PDU.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eConnect the input power:\u003c\/b\u003e Connect the L6-20P input connector on the PDU to a compatible L6-20R receptacle powered by the data-center power source. Ensure the circuit is protected and that the feed is appropriate for the total connected load.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eDistribute power to outlets:\u003c\/b\u003e Map devices to the 7 C13 outlets and the 1 C19 outlet. Plan for critical loads (e.g., main servers, storage controllers) on outlets with prioritization rules if supported by your PDU management interface.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eConfigure management and monitoring:\u003c\/b\u003e Access the PDU’s management interface via the supported method (web UI, SNMP, or DCIM integration). Create user accounts with appropriate roles, enable remote monitoring, and configure per-outlet controls and sequencing. Set up alert thresholds for current, voltage, power, and temperature if available, and enable audit logging to track changes.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eTest and validate:\u003c\/b\u003e Power on devices in a controlled sequence to verify the intended startup order. Use the outlet-level control to perform controlled reboots or maintenance cycles. Validate SNMP\/DCIM data flow and ensure that alerts and dashboards display accurate per-outlet metrics.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eQ: How many outlets does the APC AP8958NA3 provide and what are their types?\u003c\/b\u003e\u003cbr\u003eA: The unit provides 7 C13 outlets and 1 C19 outlet, allowing a mix of common data-center devices to be powered from a single, centralized PDU.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: What input power does this PDU require?\u003c\/b\u003e\u003cbr\u003eA: It uses an L6-20P input rated for 20A at 200–230V, suitable for typical data-center power feeds in many regions.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: Can I control outlets remotely?\u003c\/b\u003e\u003cbr\u003eA: Yes. The AP8958NA3 supports remote outlet-level control with programmable sequencing, enabling safe maintenance windows and orderly startup\/shutdown of connected devices.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: Does it provide real-time monitoring?\u003c\/b\u003e\u003cbr\u003eA: Yes. The PDU offers per-outlet metrics and overall load data, including current, voltage, power, and power factor to help optimize efficiency and uptime.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: What security features are included?\u003c\/b\u003e\u003cbr\u003eA: The PDU includes role-based access control, strong authentication options, and audit trails to support secure, compliant operations and centralized management integration (SNMP\/DCIM).\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: Is this suitable for high-density racks?\u003c\/b\u003e\u003cbr\u003eA: Absolutely. Its 0U footprint and high-density outlet configuration are designed for compact rack layouts while delivering scalable, reliable power distribution for dense deployments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"APC by Schneider Electric","offers":[{"title":"Default Title","offer_id":46748508717282,"sku":"2851046","price":1498.61,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0609\/9510\/9090\/files\/175530938.jpg?v=1755205415","url":"https:\/\/pegasussonline.com\/products\/apc-ap8958na3-switched-rack-pdu-0u-l6-20p-7-c13-1-c19-200-208-230v-20a","provider":"PEGASUSS ","version":"1.0","type":"link"}