{"product_id":"panduit-smartzone-g5-intelligent-24-outlets-pdu-2","title":"Panduit SmartZone G5 Intelligent 24-Outlets PDU","description":"\u003cdiv\u003e\n \u003cp\u003eDiscover advanced power management with the Panduit SmartZone G5 Intelligent 24-Outlets PDU, a high-performance, monitored power distribution unit designed for modern data centers and network closets. This 0U vertical, rack-mountable PDU delivers reliable power distribution for critical IT gear while enabling intelligent monitoring, remote management, and granular control. With a NEMA L6-30P input and a total of 24 outlets (20 IEC 60320 C13 and 4 IEC 60320 C19), it’s engineered to keep your servers, storage, and networking devices powered securely at 208 V AC. The SmartZone G5 integrates seamlessly into smart data center environments, providing visibility, control, and automation to optimize energy use, reduce downtime, and simplify firmware and configuration administration.\u003c\/p\u003e \u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMonitored power distribution\u003c\/b\u003e with real-time outlet and line monitoring: track voltage, current, power (kW), and energy usage to identify anomalies before they impact uptime. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGranular outlet-level visibility\u003c\/b\u003e for precise power budgeting: manage loads per outlet, enable load-shedding policies, and prevent overloading critical equipment during peak demand. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRemote management via network\u003c\/b\u003e using standard RJ-45 connectivity: securely access, configure, and monitor the PDU from anywhere on the network, with centralized dashboards and alerting. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRobust electrical design for reliability\u003c\/b\u003e with NEMA L6-30P input and 208 V AC output: delivers stable power for high-density deployments while maintaining electrical safety and fault isolation. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFlexible, space-saving form factor\u003c\/b\u003e 0U vertical, rack-mountable design: maximize rack space in dense data centers and telecom rooms while delivering distributed power where you need it most. \u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Details of Panduit SmartZone G5 Intelligent 24-Outlets PDU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eProduct type:\u003c\/b\u003e Monitored, 0U vertical rack-mountable PDU\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInput connection:\u003c\/b\u003e NEMA L6-30P\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInput voltage:\u003c\/b\u003e 208 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOutput outlets:\u003c\/b\u003e 24 total (20 x IEC 60320 C13, 4 x IEC 60320 C19)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMonitoring features:\u003c\/b\u003e Real-time voltage, current, power usage, energy consumption, and outlet-level status;\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRemote access:\u003c\/b\u003e RJ-45 network interface for SNMP or vendor-specific monitoring protocols\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eForm factor:\u003c\/b\u003e 0U, vertical, rack-mountable\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMounting:\u003c\/b\u003e Compatible with standard 19-inch racks and cabinets\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConfiguration options:\u003c\/b\u003e Flexible outlet grouping and load management profiles to tailor to IT workloads\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEnvironmental:\u003c\/b\u003e Typical data-center operating ranges with protection against overload and short-circuit conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCompliance:\u003c\/b\u003e Designed to meet industry standards for electrical safety and data-center infrastructure\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaintenance:\u003c\/b\u003e Firmware update capability and remote diagnostics support\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eHow to install Panduit SmartZone G5 Intelligent 24-Outlets PDU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePrepare the installation:\u003c\/b\u003e verify that the rack has adequate space for a 0U vertical PDU; confirm network access and IP addressing for remote monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMount the PDU:\u003c\/b\u003e slide the G5 into the 19-inch rack and secure with appropriate screws or hardware; ensure the unit is level and firmly fastened to prevent vibration or loosening during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConnect power input:\u003c\/b\u003e connect the NEMA L6-30P input plug to a suitable 208 V supply with appropriate breakers; ensure the circuit is rated to handle the full load plus a safety margin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWire the outlets:\u003c\/b\u003e distribute devices across the 20 C13 and 4 C19 outlets according to load planning; avoid overloading any single outlet or bank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConfigure network access:\u003c\/b\u003e connect the PDU’s RJ-45 port to your management network; configure IP address, gateway, and DNS as required for monitoring and alerting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSet monitoring and alerts:\u003c\/b\u003e use the PDU’s management interface to enable alarms for overcurrent, voltage deviation, and abnormal outlet loads; configure notification channels (email, SNMP traps, or other integrations).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTest operation:\u003c\/b\u003e power up the rack, verify outlet-level readings, and confirm that remote monitoring dashboards reflect accurate data; perform a controlled load test to confirm response to load-shedding policies if configured.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDocument configuration:\u003c\/b\u003e record the PDU’s serial number, IP address, outlet labeling, and load plan for ongoing maintenance and troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eWhat is the purpose of the Panduit SmartZone G5 PDU?\u003c\/b\u003e It provides intelligent, monitored power distribution for racks, enabling real-time visibility into voltage, current, and outlet-level usage to support proactive capacity planning and uptime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHow many outlets does this PDU provide and what types?\u003c\/b\u003e It offers 24 outlets: 20 IEC 60320 C13 and 4 IEC 60320 C19 outlets, all configured for 208 V input\/output in a 0U vertical form factor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCan I monitor this PDU remotely?\u003c\/b\u003e Yes. It features an RJ-45 network interface for remote monitoring, alerting, and management from centralized dashboards or compatible data-center management systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWhat input plug does it use?\u003c\/b\u003e The unit uses a NEMA L6-30P input plug, suitable for 208 V single-phase power_distribution in data-center environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIs the PDU rack-mountable?\u003c\/b\u003e Yes. It is designed for 0U vertical mounting in standard 19-inch racks, optimizing space in dense server rooms and cabinet enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDoes it support outlet-level load balancing?\u003c\/b\u003e The SmartZone G5 provides outlet-level monitoring and load-management features that help prevent overloads and enable energy-smart policies across the rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Panduit","offers":[{"title":"Default Title","offer_id":46754677981410,"sku":"12745196","price":1436.68,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0609\/9510\/9090\/files\/175553351.jpg?v=1754848850","url":"https:\/\/pegasussonline.com\/products\/panduit-smartzone-g5-intelligent-24-outlets-pdu-2","provider":"PEGASUSS ","version":"1.0","type":"link"}