{"product_id":"raritan-px3-36-outlets-pdu-1ph-208v-24a-20xc13-6xc19-nema-l6-30p-5-0kva-0u-red","title":"Raritan Px3 36 Outlets Pdu 1Ph 208V 24A 20Xc13 6Xc19 Nema L6 30P 5 0Kva 0U Red","description":"\u003cdiv\u003e\n\u003cp\u003eEngineered for demanding data centers, the Raritan PX3 36-Outlets PDU delivers reliable, flexible power distribution in a compact 0U, rack-mountable enclosure. Designed for high-density racks, it consolidates 36 outlets into a single footprint, including 30 IEC 60320 C13 receptacles and 6 IEC 60320 C19 receptacles, all powered from a secure NEMA L6-30P input. Optimized for 208V single-phase environments, this PDU provides a robust, space-saving solution that enhances uptime and simplifies cable management for servers, storage, and networking gear in busy cabinets.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cb\u003e0U, rack-mountable footprint:\u003c\/b\u003e Sits flush in a standard 19\" rack, preserving vertical space for active equipment and improving front-to-back airflow for better cooling.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003e36 versatile outlets:\u003c\/b\u003e 30 x IEC 60320 C13 and 6 x IEC 60320 C19 receptacles offer broad compatibility for mixed IT gear in a single centralized unit, reducing the need for multiple power strips.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eSecure, locking input:\u003c\/b\u003e NEMA L6-30P inlet eliminates accidental disconnections and helps keep critical equipment powered during busy operations and maintenance cycles.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eSingle-phase, efficient power distribution:\u003c\/b\u003e Reliable, straightforward power delivery suitable for most data-center and IT closet deployments with simplified cabling and predictable load behavior.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eDurable design for high-demand environments:\u003c\/b\u003e Built to support continuous operation, streamline cable management, and improve overall rack organization in busy cabinets while withstanding daily use.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Details of Raritan PX3 36-Outlets PDU\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eOutlets:\u003c\/b\u003e 36 total — 30 x IEC 60320 C13 and 6 x IEC 60320 C19 receptacles.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eInput\/Plug:\u003c\/b\u003e NEMA L6-30P.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eForm Factor:\u003c\/b\u003e 0U rack-mountable enclosure compatible with standard 19\" racks.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003ePhase:\u003c\/b\u003e Single-phase power distribution.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eMounting:\u003c\/b\u003e Rack-mountable in a 19\" rack, suitable for data centers, server rooms, and network closets.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eOutlet arrangement flexibility:\u003c\/b\u003e Supports a mix of IT equipment with diverse power requirements in a single, centralized unit.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eHow to install Raritan PX3 36-Outlets PDU\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003ePrepare the rack:\u003c\/b\u003e Ensure the chosen rack location has adequate ventilation and airflow. Verify that the rack’s rated load can support the combined power requirements of connected devices and the PDU itself to avoid overloading the circuit.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eMount the PDU:\u003c\/b\u003e Align the PX3 with the 19\" rack rails and secure it using the appropriate screws for your rack type. Confirm that the PDU sits securely and remains level, with no strain on cables or connectors.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eConnect the inlet power:\u003c\/b\u003e Plug the NEMA L6-30P input cord into a compatible L6-30R receptacle or power path supplied by your data center. Ensure the corresponding circuit breaker is sized to support the expected load of connected devices and leave headroom for startup surges.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eRoute and manage cables:\u003c\/b\u003e Route IEC C13 and C19 cables neatly to maintain proper airflow and minimize cable tension. Use built-in or external cable management features to keep cables organized, labeled, and accessible for maintenance or replacements.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003ePower up and verify:\u003c\/b\u003e Power on the PDU and verify that all outlets are delivering power to their respective devices. Check that the locking input remains secure and that cables are free of obstruction to airflow. Perform a basic load check and document connections for future reference and routine maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch4\u003eFrequently asked questions\u003c\/h4\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eWhat outlets are included?\u003c\/b\u003e The PX3 provides 36 outlets in total — 30 IEC 60320 C13 and 6 IEC 60320 C19 receptacles, giving broad support for mixed IT equipment in a single unit.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eWhat is the input connector?\u003c\/b\u003e It uses a NEMA L6-30P locking plug for a secure power input, reducing the risk of accidental disconnections in busy racks.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eWhat is the footprint?\u003c\/b\u003e The unit is a 0U, rack-mountable PDU designed to sit flush in a standard 19\" rack, freeing vertical space for active equipment and improving airflow pathways.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eIs it single-phase or three-phase?\u003c\/b\u003e The PX3 is designed for single-phase power distribution, suitable for most data-center deployments and IT closet environments.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eHow do I install it?\u003c\/b\u003e Follow the installation steps outlined in the installation section: prepare the rack, mount the PDU, connect the inlet, route and manage cables, and power up to verify operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Raritan","offers":[{"title":"Default Title","offer_id":46756348657890,"sku":"5512760","price":2500.48,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0609\/9510\/9090\/files\/242756579.jpg?v=1754890428","url":"https:\/\/pegasussonline.com\/products\/raritan-px3-36-outlets-pdu-1ph-208v-24a-20xc13-6xc19-nema-l6-30p-5-0kva-0u-red","provider":"PEGASUSS ","version":"1.0","type":"link"}