{"product_id":"tripp-lite-by-eaton-28-8kw-220-240v-3ph-switched-pdu-lx-interface-gigabit-24-outlets-hardwire-380-415v-input-lcd-1-8-m-cord-0u-1-8-m-height-taa","title":"Tripp Lite by Eaton 28.8kW 220-240V 3PH Switched PDU - LX Interface, Gigabit, 24 Outlets, Hardwire 380-415V Input, LCD, 1.8 m Cord, 0U 1.8 m Height, TAA","description":"\u003cdiv\u003e\n\u003ch1\u003eTripp Lite by Eaton 28.8kW 220-240V 3PH Switched PDU - LX Interface, Gigabit, 24 Outlets, Hardwire 380-415V Input, LCD, 1.8 m Cord, 0U 1.8 m Height, TAA\u003c\/h1\u003e\n\u003cp\u003eThis Tripp Lite by Eaton switched power distribution unit is engineered for the most demanding data centers, server rooms, and network closets. It combines high-density electrical distribution with intelligent, network-enabled power control, giving you granular visibility and control across every outlet. With a 28.8 kW capacity, three-phase input, and a 24-outlet configuration, this PDU is built to support modern rack deployments that demand reliability, uptime, and efficient power management. The LX interface, a rugged LCD readout, and Gigabit networking make it easy to monitor power usage, set policies, and respond to events in real time, all while maintaining tight control over energy consumption and device startup sequences. Whether you’re consolidating servers, deploying hyper-converged infrastructure, or deploying edge computing in network closets, this PDU helps you optimize power delivery and operational efficiency at scale.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cb\u003eAdvanced remote power control:\u003c\/b\u003e Turn on, turn off, reboot, or lock out power to individual outlets from anywhere on the network. This capability is essential for automating maintenance, applying update cycles, and implementing rapid fault isolation without requiring on-site visits. The switched outlets empower you to orchestrate graceful reboots, staggered power-on sequences, and policy-driven power management that minimizes downtime and protects critical workloads.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eHigh-density distribution with scalable capacity:\u003c\/b\u003e A 28.8 kW total power rating supports densely packed racks and high-performance servers. With 24 individual outlets, you can distribute loads precisely where they’re needed, reducing the risk of outlet overloading and enabling more efficient use of rack space. The compact, 0U footprint maximizes cabinet real estate while delivering robust electrical distribution for your IT infrastructure.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eLX interface with LCD for local and remote management:\u003c\/b\u003e The LX interface provides an intuitive local management experience, showing real-time measurements, outlet status, and configuration options directly on the built-in LCD. For remote administration, you can leverage the Gigabit network interface to monitor, configure, and control the PDU via standard management protocols. This dual-access approach ensures you have immediate visibility on the unit and remote access for centralized control.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eGigabit network management and security features:\u003c\/b\u003e The PDU supports a modern management stack with reliable remote monitoring, alerting, and control. Network visibility includes status alerts, energy consumption reporting, and the ability to perform controlled power cycles. Robust security features guard access to critical power controls, ensuring that only authorized personnel can modify outlet states.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eRugged build for data centers and government procurement (TAA-compliant):\u003c\/b\u003e Designed to endure the rigors of data-center environments, this PDU is built to meet stringent industry standards and is TAA compliant for government and contractor procurement. The combination of reliability, precise control, and compliance makes it suitable for enterprise deployments, managed service providers, and regulated environments alike.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Details of Tripp Lite by Eaton 28.8kW Switched PDU\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003ePower capacity:\u003c\/b\u003e 28.8 kW total load rating, enabling scalable distribution for high-density rack deployments.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eInput configuration:\u003c\/b\u003e Hardwired 380-415V, three-phase input to accommodate data-center power distribution strategies and high-availability architectures.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eOutput outlets:\u003c\/b\u003e 24 outlets for comprehensive distribution across multiple devices within the rack, supporting diverse IT hardware footprints.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eOutput control:\u003c\/b\u003e Switched outlets with remote on\/off, reboot, and lockout capabilities for granular power management and fault isolation.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eManagement interface:\u003c\/b\u003e LX local interface with LCD display for at-a-glance status and configuration; integrated Gigabit network interface for remote management.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eNetwork capabilities:\u003c\/b\u003e Gigabit connectivity supports secure, scalable remote monitoring, alerting, and control via standard protocols (e.g., SNMP\/Web UI).\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eCord and length:\u003c\/b\u003e 1.8 m power cord for flexible installation and reach within racks or adjacent cabinets.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eForm factor:\u003c\/b\u003e 0U footprint to maximize rack space; designed for mounting within standard equipment racks without sacrificing accessibility or serviceability.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eDimensions and orientation:\u003c\/b\u003e Long, compact design suitable for 1U-per-outlet density planning with a focus on unobtrusive integration in dense environments.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eCompliance:\u003c\/b\u003e TAA-compliant, suitable for government and enterprise procurement programs that require traceable and verifiable sourcing.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eVoltage range:\u003c\/b\u003e 220-240V nominal (three-phase), aligned with data-center distribution standards for efficient, balanced loading across legs.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eOperating environment:\u003c\/b\u003e Built to operate reliably in data-center environments with robust electrical noise rejection and thermal tolerance.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eHow to Install Tripp Lite by Eaton 28.8kW Switched PDU\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003ePlan and prepare:\u003c\/b\u003e Assess rack space, cable routing, and cooling considerations. Ensure your data center power distribution architecture aligns with a 380-415V three-phase supply and that the selected rack can accommodate a 0U PDU with a 1.8 m length for reach and alignment with outlets and equipment.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eMount the PDU in the rack:\u003c\/b\u003e Install the 0U chassis securely in the rack using the appropriate mounting hardware. Verify that there is clearance for the LCD display and the network port, and that venting is unobstructed to maintain proper airflow around the PDU.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eConnect the power input:\u003c\/b\u003e Hardwire the PDU to the 380-415V three-phase supply per local electrical codes. Confirm that circuit breakers and feeders are rated for the expected load and that proper grounding is in place before energizing the system.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eEstablish network and local access:\u003c\/b\u003e Connect the PDU’s Gigabit Ethernet port to your management network. Use the LCD interface for initial onboarding, IP configuration, and basic status checks, then switch to the web UI or SNMP-based management for ongoing operations.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eConfigure outlets and policies:\u003c\/b\u003e Use the LX LCD to label each outlet, group outlets by function or device type, and set up power-on\/off sequences, alert thresholds, and reboot policies. Create outlet-specific permissions to ensure only authorized personnel can perform critical actions.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eTest and verify:\u003c\/b\u003e Power on connected devices in a controlled sequence, verify that each outlet responds to remote commands, and confirm that status indicators, alarms, and energy measurements reflect real-world operation. Validate that reboot, power-cycling, and lockout features function as intended.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eDocument and monitor:\u003c\/b\u003e Record the PDU’s IP address, outlet mappings, and configured policies in your data-center runbooks. Enable continuous monitoring, set up email or SNMP alerts for over-current events, and test remediation workflows to ensure rapid response during faults.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eQ: What does LX interface mean?\u003c\/b\u003e A: The LX interface is the local management panel that lets you view status, configure outlets, and perform control actions directly on the PDU using its built-in LCD display. It complements remote management over the Gigabit Ethernet interface for a complete management solution.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: How many outlets does this PDU have?\u003c\/b\u003e A: It features 24 outlets, enabling flexible distribution for multiple servers, network devices, and other rack-mounted equipment within a single unit.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: What input voltage does this PDU require?\u003c\/b\u003e A: The PDU is designed for 380-415V hardwired, three-phase input, with a nominal 220-240V per phase configuration for connected devices. This makes it suitable for data-center power distribution architectures that favor higher voltage distribution.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: Can I remotely reboot individual outlets?\u003c\/b\u003e A: Yes. Each outlet can be controlled remotely to reboot or power cycle connected devices. This is essential for maintenance windows, firmware updates, and rapid fault isolation without on-site intervention.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: Is the PDU compliant with government procurement standards?\u003c\/b\u003e A: Yes. The unit is TAA-compliant, making it eligible for government, procurement programs, and contractors that require traceable sourcing.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: What management methods are supported?\u003c\/b\u003e A: Remote management is supported through Gigabit Ethernet with a web UI and standard management protocols (e.g., SNMP). Local management is available via the built-in LCD on the LX interface for quick status checks and configuration.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: What is the footprint and physical fit?\u003c\/b\u003e A: The PDU has a 0U footprint, designed to maximize rack space. It is a long, low-profile unit with a 1.8 m length that reaches across a row of devices, simplifying outlet placement and cabling.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: Is this suitable for high-density data centers?\u003c\/b\u003e A: Yes. With a 28.8 kW capacity and 24 outlets, the unit supports high-density deployments and scalable expansion while maintaining centralized power control and monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Tripp Lite by Eaton","offers":[{"title":"Default Title","offer_id":46749854269666,"sku":"5363524","price":1463.37,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0609\/9510\/9090\/files\/175563951.jpg?v=1755352663","url":"https:\/\/pegasussonline.com\/products\/tripp-lite-by-eaton-28-8kw-220-240v-3ph-switched-pdu-lx-interface-gigabit-24-outlets-hardwire-380-415v-input-lcd-1-8-m-cord-0u-1-8-m-height-taa","provider":"PEGASUSS ","version":"1.0","type":"link"}