Description
Power reliability matters when critical systems must stay online no matter what. The Tripp Lite by Eaton APS X Series 4000W inverter/charger delivers dependable, clean power for backup and off-grid applications by converting a 48VDC battery supply into stable 220–240V AC with pure sine-wave output. Designed for use where seamless transition and hardwired integration are non-negotiable, this unit combines a high continuous power rating with a substantial surge capacity, smart automatic transfer switching, and rugged construction to excel in data centers, communications rooms, medical clinics, remote work sites, and well‑protected home installations. Its ability to run sensitive electronics, motor-driven devices, and efficient loads with minimal distortion makes it a versatile centerpiece for any power reliability strategy. With its ATS-enabled design, you get automatic, rapid handover between utility or generator power and battery power, preserving uptime for essential circuits without disruption.
- Pure sine-wave output ensures clean, stable power that protects sensitive electronics, servers, POS systems, and medical devices from harmonic distortion, voltage sags, and frequency fluctuations, reducing wear and nuisance outages.
- 4000W continuous power with up to 8000W peak capability handles demanding loads and startup surges, supporting multi‑load configurations such as network gear, cooling systems, lighting, and essential appliances without sacrificing performance.
- 48V DC input and 220–240V AC output provide a robust bridge between a battery bank and your electrical system, enabling efficient charging from AC sources while delivering standard high‑voltage AC to on-site equipment.
- Auto-transfer switching (ATS) automatically swaps between AC utility/generator power and battery power, delivering seamless handoffs for uninterrupted operation of critical loads during outages or fluctuations in the input supply.
- Hardwired installation supports professional, code‑compliant integration into a building’s electrical backbone, simplifying a clean, reliable connection to distribution panels and separate load circuits while keeping the inverter out of sight in a dedicated equipment space.
Technical Details of Tripp Lite by Eaton 4000W APS X Series 48VDC Inverter/Charger
- Inverter type: Pure sine-wave output for compatibility with sensitive electronics and motor loads.
- Continuous output power: 4000 W, enabling sustained operation of multiple critical devices and systems.
- Peak power: 8000 W, providing ample headroom for high‑inrush equipment during startup.
- Input voltage: 48 V DC (battery) with 220–240 VAC AC input options for charging and top‑ups from utility or generator sources.
- Output voltage: 220–240 VAC, compatible with standard international electrical systems and appliances designed for this range.
- Automatic Transfer Switch (ATS): Yes, enabling automatic switchover between AC source power and battery power to maintain loads without manual intervention.
- Connection method: Hardwired installation for secure, code-compliant integration into the building’s electrical distribution.
How to Install Tripp Lite by Eaton 4000W APS X Series 48VDC Inverter/Charger
Proper installation ensures maximum reliability, safety, and performance. Follow these general steps to integrate the inverter/charger into your backup power system. Always consult the official installation manual and comply with local electrical codes and safety standards, and consider professional electrical assistance for high‑voltage connections.
1) Plan the layout and ventilation: Locate the inverter/charger in a well‑ventilated equipment room or cabinet with adequate clearance for cooling. Avoid confined spaces that trap heat, as high ambient temps reduce efficiency and shorten component life. Provide an unobstructed exhaust path and keep dust and moisture away from the unit.
2) Connect the battery bank (DC side): Attach a properly rated 48V DC battery bank to the inverter’s DC input terminals using suitably gauged battery cables. Observe correct polarity (+/-) and secure all connections with appropriate hardware. Ensure a solid, corrosion‑free ground reference as specified in the installation guide.
3) Wire the AC input and output (AC side): Connect the AC input to a dedicated circuit that can supply the charging function from utility power or a generator. Route the AC output to the appropriate distribution panel or to the critical loads you intend to back up. If required, coordinate with an electrician to install the correct breakers and wiring sizes for 220–240V circuits.
4) Enable and configure ATS settings: Verify that the automatic transfer switch is enabled and configured for your preferred source priorities. Some installations use load priority to favor utility power when available, with battery power reserved for essential circuits. Set voltage and transfer parameters per the manual and ensure protective devices are in place to prevent backfeeding or faults.
5) Perform a system test: With the battery connected and sources configured, test the system by simulating a power outage to confirm seamless handover to battery power. Validate that critical loads remain energized and that the inverter remains within safe operating temperatures. Gradually introduce loading to confirm surge performance and ensure no tripping occurs under peak demand.
6) Safety and ongoing maintenance: Provide proper labeling on the equipment, secure enclosure panels, and ensure all cables are neatly organized. Schedule periodic inspections of connections, battery health, and cooling fans. Maintain clear airflow around the unit and replace DC battery banks as they reach end‑of‑life to preserve performance and reliability.
Frequently asked questions
-
Q: What kind of loads is the 4000W APS X Series suited for?
A: It is designed to support essential electrical loads with high reliability, including servers, networking equipment, medical devices, climate control systems, lighting, and other critical devices that require clean, stable power and rapid transition during outages. -
Q: What voltage levels does it use for input and output?
A: The unit uses 48V DC for battery input and supplies 220–240V AC on the output. It also accepts 220–240V AC input for charging when utility or generator power is available. -
Q: How does the automatic transfer switch work?
A: The ATS continuously monitors the AC input source. When it detects an outage or unacceptable voltage, it automatically switches to battery power to keep essential circuits energized, then returns to utility power when the source is healthy again, all without manual intervention. -
Q: Can I hardwire this inverter/charger into my electrical system?
A: Yes. It is designed for hardwired installation, enabling secure, code-compliant connections to your distribution panel and loads. Professional installation is recommended for safety and compliance. -
Q: Is there a surge capacity and how does it help?
A: The unit provides 8000W peak power, allowing rapid handling of startup surges for devices like HVAC compressors, pumps, and other high inrush equipment without tripping or brownouts.