{"product_id":"vertiv-liebert-exs-v-model-ups-tower-20kva-20kw-208-120vac220-127vac-3-phase-4-wire-top-fan-w-snmp-run-time-13-min-exsv-20kxrtn","title":"Vertiv Liebert EXS V-Model UPS tower 20kVA\/20kW 208\/120VAC(220\/127VAC) 3-Phase 4 Wire|Top Fan w\/ SNMP|Run Time 13 min (EXSV-20KXRTN)","description":"\u003cdiv\u003e\n \u003cp\u003eThe Vertiv Liebert EXS V-Model (EXSV-20KXRTN) is a compact, monolithic online UPS designed to deliver reliable, clean power for critical IT infrastructure. Built around true online, double-conversion technology, it continuously conditions and regulates output voltage to protect servers, networking equipment, and data storage from power disturbances. With a 20 kVA \/ 20 kW rating and 3-phase, 4-wire input\/output, the EXS V-Model is engineered to meet demanding load profiles in data centers, telecom rooms, and network closets while occupying a compact footprint suitable for space-constrained environments. The integrated top-fan cooling improves reliability in hot environments, and its SNMP capability enables seamless remote management and proactive monitoring.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cb\u003eUnmatched power protection with online double-conversion:\u003c\/b\u003e The EXS V-Model delivers a continuous, clean sine-wave output regardless of input disturbances, ensuring consistent performance for sensitive IT equipment and minimizing data loss during outages.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003e20 kVA \/ 20 kW capacity in a compact monolithic design:\u003c\/b\u003e A robust, space-efficient solution that supports growth and consolidates critical loads without compromising protection or efficiency.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003e3-Phase, 4-Wire configuration at 208\/120 VAC (220\/127 VAC):\u003c\/b\u003e Flexible utility compatibility for modern data centers, with options to match regional power standards and IT equipment requirements.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eTop-fan cooling and remote monitoring capabilities:\u003c\/b\u003e Superior thermal management keeps the unit operating at peak performance, while SNMP and network connectivity enable proactive maintenance and fast issue resolution.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003e13-minute runtime:\u003c\/b\u003e A practical runtime to bridge short outages and safeguard servers and network gear during power events, allowing orderly shutdowns or seamless switchover to backup generation where available.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Details of Vertiv Liebert EXS V-Model UPS\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eModel:\u003c\/b\u003e EXSV-20KXRTN\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eTopology:\u003c\/b\u003e True online, double-conversion (monolithic UPS)\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003ePower Rating:\u003c\/b\u003e 20 kVA \/ 20 kW\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eInput\/Output Voltage:\u003c\/b\u003e 208\/120 VAC (with 220\/127 VAC tolerance), 3-Phase, 4-Wire\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eOutput Waveform:\u003c\/b\u003e Pure sine wave\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eCooling:\u003c\/b\u003e Top Fan cooling for efficient heat dissipation\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eMonitoring:\u003c\/b\u003e SNMP capable (network management for remote monitoring and alerts)\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eRuntime (Run Time):\u003c\/b\u003e Approximately 13 minutes (specific runtime depends on load)\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eProtection Features:\u003c\/b\u003e Input surge protection, short-circuit protection, overload protection, and automatic bypass capability\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eForm Factor:\u003c\/b\u003e Compact monolithic design suitable for space-constrained environments\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eEfficiency:\u003c\/b\u003e High-efficiency operation to reduce energy costs and cooling requirements\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eHow to install Vertiv Liebert EXS V-Model UPS\u003c\/h2\u003e\n\u003cp\u003eCareful installation is essential to maximize reliability and protection. The Vertiv Liebert EXS V-Model should be placed on a level, vibration-free surface with adequate clearance for cooling and maintenance. Before installation, confirm that the service area meets the electrical, environmental, and safety requirements outlined in the user manual. The following guidelines help ensure a smooth deployment:\u003c\/p\u003e \u003cp\u003eStep-by-step guidance:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cb\u003eSite readiness:\u003c\/b\u003e Ensure the installation location provides structural support for the unit’s weight, proper ventilation, and access for maintenance. Maintain ambient temperatures within the recommended range and keep the area free of dust and obstructions.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eElectrical connections:\u003c\/b\u003e Connect the three-phase, four-wire input to the appropriate power source, ensuring correct voltage and phase alignment. Use correctly rated cables and secure all connections to prevent impedance-related issues.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eLoad assessment and distribution:\u003c\/b\u003e Map critical loads to the UPS output and verify that total connected load does not exceed the 20 kW rating. Consider future expansion and implement proper load balancing to optimize performance.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eCabling and grounding:\u003c\/b\u003e Route output cables to IT equipment with attention to separation from EMI sources. Ground the UPS per local codes and the manufacturer’s recommendations to ensure safety and performance.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eSNMP and network configuration:\u003c\/b\u003e Install the SNMP management module if not pre-installed, then configure IP addressing, community strings, and alert thresholds to enable remote monitoring and proactive maintenance.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eCommissioning and testing:\u003c\/b\u003e Power up the system with a slow ramp, verify alarm indicators, perform a functional test by simulating a power outage, and confirm seamless transfer to an auxiliary power path or battery reserve as designed.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eDocumentation and maintenance planning:\u003c\/b\u003e Record serial numbers, firmware versions, and configuration settings. Establish a preventive maintenance schedule to maximize uptime and extend service life.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eWhen installed correctly, the Vertiv Liebert EXS V-Model delivers dependable power quality, preventing disturbances like sags, swells, and outages from propagating to critical IT equipment. Its modular design, robust protection features, and remote monitoring capabilities enable IT teams to manage risk, improve uptime, and simplify disaster recovery planning. For data centers and networks with demanding workloads, the EXSV-20KXRTN offers a scalable, reliable, and efficient power solution that aligns with modern IT architectures and energy-conscious operations.\u003c\/p\u003e \u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eQ: What loads is the EXSV-20KXRTN best suited for?\u003c\/b\u003e \u003cp\u003eA: The EXSV-20KXRTN is ideal for mid-range data centers, server rooms, and network closets that require robust 3-phase online UPS protection for mission-critical servers, storage devices, and network equipment.\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: What does 3-Phase 4-Wire mean for my installation?\u003c\/b\u003e \u003cp\u003eA: 3-phase 4-wire means the UPS connects to a three-phase electrical supply with a neutral conductor, supporting balanced loading and compatibility with typical large IT loads and building power systems.\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: How does SNMP monitoring benefit my operation?\u003c\/b\u003e \u003cp\u003eA: SNMP enables remote health monitoring, alerts, and performance data collection, allowing IT teams to respond quickly to outages, plan maintenance, and optimize energy usage without on-site visits.\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: What is the runtime and how does it impact downtime?\u003c\/b\u003e \u003cp\u003eA: The EXSV-20KXRTN provides approximately 13 minutes of runtime, which is designed to bridge short outages and allow orderly shutdowns or seamless switchover to backup power when available, reducing the risk of data loss.\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eQ: Can I expand the system as my needs grow?\u003c\/b\u003e \u003cp\u003eA: Yes. The Liebert EXS V-Model is engineered for scalability, with options for additional battery back-ups and integration with larger power architectures to accommodate increasing loads while maintaining protection.\u003c\/p\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Liebert","offers":[{"title":"Default Title","offer_id":46747639546082,"sku":"9361552","price":23338.2,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0609\/9510\/9090\/files\/175565518.jpg?v=1755355262","url":"https:\/\/pegasussonline.com\/products\/vertiv-liebert-exs-v-model-ups-tower-20kva-20kw-208-120vac220-127vac-3-phase-4-wire-top-fan-w-snmp-run-time-13-min-exsv-20kxrtn","provider":"PEGASUSS ","version":"1.0","type":"link"}