Description
20U Copper Busbar Kit for NetShelter AV Enclosures
Engineered to streamline rack installation and elevate safety in critical IT environments, the 20U Copper Busbar Kit for NetShelter AV Enclosures delivers a robust, copper-based mounting solution designed for high-strength performance and lasting durability. This premium accessory is crafted to secure racks within NetShelter AV enclosures, providing a dependable mounting bar that enhances organization, grounding, and overall productivity for data centers, server rooms, and professional IT environments. Built with copper to maximize conductivity and structural integrity, this busbar kit is a pivotal addition to any rack deployment where reliability and efficiency matter most.
- High-strength copper construction: The copper busbar ensures superior durability and mechanical stability, delivering a resilient mounting solution that withstands rigorous daily use in busy data centers and network closets.
- 20U mounting capacity: Specifically designed to fit a 20U vertical space, this kit provides ample room for rack-mounted IT equipment while maintaining a clean, organized enclosure interior.
- Enhanced grounding and electrical performance: Copper’s exceptional conductivity translates into reliable grounding and reduced resistance, contributing to safer operation and improved electrical efficiency for rack-mounted devices.
- Secure, tool-friendly installation: The mounting bar is engineered for straightforward attachment to NetShelter AV enclosures, enabling faster, more accurate installations with minimal downtime.
- Versatile enclosure compatibility: Optimized for NetShelter AV series, this busbar kit integrates seamlessly with standard rack rails to support a wide range of IT equipment, from servers to storage to network gear.
Technical Details of 20U Copper Busbar Kit for NetShelter AV Enclosures
- Material: Copper
- Height/Size: 20U busbar kit designed for NetShelter AV enclosures
- Compatibility: NetShelter AV enclosure family (rack-mount configurations)
- Mounting: Rack-mount installation with standard hardware for secure attachment
- Primary benefit: Superior electrical conductivity and dependable mechanical strength
- Includes: Mounting bar with hardware needed for installation
How to install 20U Copper Busbar Kit for NetShelter AV Enclosures
- Prepare the enclosure: Ensure the NetShelter AV enclosure is powered down and all cables are safely managed. Verify rail alignment and confirm there is a suitable 20U space available for the busbar kit.
- Align the busbar: Position the copper mounting bar along the designated rails inside the enclosure. Double-check that the bar sits level and that mounting holes align with the enclosure’s framework.
- Attach mounting hardware: Use the provided screws, washers, and fasteners to secure the busbar to the enclosure rails. Tighten steadily with a suitable tool, taking care not to overtighten and risk damaging the rails.
- Verify grounding continuity: Connect any grounding wires or straps as specified by your installation guidelines. Confirm continuity between the copper busbar and the enclosure chassis to ensure a reliable ground path.
- Install equipment and test: Begin loading rack-mounted devices onto the rails, ensuring balanced weight distribution. Power on the system and perform a standard functional test to verify stability, alignment, and electrical performance.
Frequently asked questions
-
What is the 20U Copper Busbar Kit used for?
This kit provides a durable, copper-based mounting bar designed to secure equipment within NetShelter AV enclosures. It optimizes mounting reliability, grounding, and organization for rack-mounted IT hardware. -
Is the kit compatible with all NetShelter AV enclosure models?
The kit is designed for NetShelter AV enclosures with standard rail configurations that accommodate a 20U mounting solution. Always confirm compatibility with your specific enclosure model and rail spacing before installation. -
What are the key benefits of copper construction?
Copper offers exceptional electrical conductivity, improved grounding, and strong mechanical properties that contribute to safer operation, reduced resistance, and long-term durability in demanding data center environments. -
What tools are needed for installation?
Typically, standard screwdrivers or wrenches compatible with the included mounting hardware are sufficient. It’s recommended to have a tape measure for alignment checks and a continuity tester to verify grounding after installation.
Customer reviews
Showing - Of Reviews