2N Intercom System Wiegand Module

2NSKU: 12289799

Price:
Sale price$125.76

Description

2N Intercom System Wiegand Module – Commercial Access Control

The 2N Intercom System Wiegand Module is a purpose-built extension designed for commercial environments where secure, scalable access control is essential. This compact add-on plugs into compatible 2N intercom systems to bridge real-time visitor communication with standard Wiegand interfaces used by door controllers and access points. By translating intercom events into reliable Wiegand pulses, it enables fast, authorized door releases without requiring a full system overhaul. The result is a streamlined security workflow that reduces installation time, lowers total cost of ownership, and improves auditability across multi-tenant buildings, offices, hotels, and campus facilities. Built to endure the rigors of busy commercial settings, the module delivers consistent performance, robust signal integrity, and seamless integration with existing security ecosystems. Whether you are upgrading an older intercom estate or expanding a fortified entry for new tenants, this Wiegand Module offers a dependable, scalable path to unified access management.

  • The module provides seamless Wiegand interface integration, translating intercom events into standard Wiegand pulses that drive door controllers and access readers. This enables immediate, secure triggering of door releases for recognized visitors while maintaining an unobtrusive footprint in the installation space.
  • Its compact, plug‑in design fits neatly behind the 2N intercom unit or inside a nearby enclosure, preserving a clean installation with minimal cabling. The unobtrusive form factor helps simplify retrofits and new builds alike, reducing the need for invasive wiring work while preserving the original intercom aesthetics.
  • Format flexibility ensures compatibility with a wide range of access control systems. The module supports common Wiegand formats and can be configured to match the bit length used by your reader system, enabling compatibility across multiple vendors and tenant configurations without custom programming.
  • Security and reliability are at the forefront, with low-latency operation that preserves audio and signaling timing, tamper‑resistant mounting options, and robust connectors designed for the often harsh conditions of commercial environments. The result is dependable performance even in high-traffic entrances.
  • Easy setup and comprehensive documentation help facilities teams move quickly from install to live operation. Wiring diagrams, quick-start guides, and configuration notes provide a clear path to successful deployment, allowing technicians to configure the module with confidence and accuracy.

Technical Details of 2N Intercom System Wiegand Module

Technical specifications for this module are dependent on the specific 2N intercom model and the affiliated access control system. The details below reflect typical capabilities described in official product listings and catalog references when cross‑referencing UPCs or SKUs in vendor portals. Please note that exact figures may vary by configuration and regional version.

  • Interface: Wiegand-compatible output designed to integrate with standard door controllers and access readers used in commercial security systems.
  • Power and duty: Draws minimal power from the host intercom system and does not require a separate power supply in standard configurations, helping to simplify rack‑space and enclosure planning.
  • Form factor: Compact, modular design intended for easy mounting inside intercom enclosures or adjacent electrical boxes, reducing installation footprint and preserving enclosure integrity.
  • Compatibility: Engineered to work with a wide range of 2N intercom models and access control setups that accept Wiegand input, supporting multi‑tenant and multi‑zone configurations where applicable.
  • Durability and build: Constructed for reliable operation within commercial environments, with secure connection points and robust cabling options to withstand daily usage and wiring flex.

How to Install 2N Intercom System Wiegand Module

  • Prepare the installation site by powering down the main intercom system and related network equipment. This step minimizes the risk of electrical interference and ensures safe handling of wiring connections during installation.
  • Identify the Wiegand interface terminals on the intercom unit and the corresponding inputs on the external access control system. Refer to the included wiring diagram to confirm pin assignments, signal polarity, and any required termination or pull‑up configurations.
  • Connect the Wiegand Module to the intercom’s Wiegand port using the supplied cable and connectors. Ensure secure, vibration‑resistant connections and route wires away from high‑voltage or network cables to reduce interference and maintain signal integrity.
  • Mount the Wiegand Module in a suitable enclosure or behind the intercom housing, using the provided hardware. Verify that the device is firmly seated and that cables have sufficient slack for maintenance while avoiding strain on the connectors.
  • Configure the module according to the documentation—select the appropriate Wiegand format, terminal assignments, and any tenant or site‑level options. Perform a functional test by presenting authorized credentials to confirm door release and signal timing align with your access controller expectations.
  • Validate operation under realistic conditions, including peak access times and different credential types (cards, fobs, or PINs if supported). Check for any audio or signaling anomalies and adjust wiring or jumper settings as needed to optimize performance.
  • Document the installation for security auditing and future maintenance. Record the SKU/UPC reference, configuration details, and the wiring map so technicians can reproduce or modify the setup as your access control needs evolve.

Frequently asked questions

  • What is the purpose of the 2N Intercom System Wiegand Module?
  • The module enables compatibility between a 2N intercom system and external access control systems that use the Wiegand interface. It translates intercom events into Wiegand signals, allowing authorized visitors to trigger door releases in a secure, auditable manner without replacing the entire security infrastructure.

  • What kinds of access control systems work with this module?
  • Most standard access controllers that accept Wiegand inputs can work with the module, making it suitable for a range of commercial environments. Compatibility depends on the specific Wiegand format and the controller’s supported bit length, so matching formats is essential for reliable operation.

  • Is professional installation required?
  • While technically skilled installers can configure and mount the module, the product is designed to streamline integration and can be set up by qualified facilities or security technicians. Always follow local electrical and building codes and review the wiring diagrams closely to ensure proper operation and safety.

  • Can I upgrade existing installations without replacing the intercom?
  • Yes. The Wiegand Module is specifically intended to extend the capabilities of existing 2N intercom systems, enabling modern access control features with minimal disruption. This approach preserves your current investment while adding scalable, secure entry management.