Advantech 2-ch Counter/Frequency Module

AdvantechSKU: 6446784

Price:
Sale price$194.57

Description

Advantech ADAM-4080/4080D: 2-Channel Counter and Frequency Input Module

Engineered for precision and reliability in industrial automation, the Advantech ADAM-4080/4080D Counter/Frequency Module delivers robust two-channel counter input with 32-bit resolution and a built-in programmable timer for frequency measurement. This compact, cost-effective module is designed for seamless integration into Advantech data acquisition systems, enabling real-time counting, edge detection, and timing with minimal software overhead. Whether you are monitoring production line counts, RPM, pulse rates, or event timing, the ADAM-4080/4080D provides accurate data capture and dependable performance in harsh environments. Its small footprint and rugged construction make it ideal for OEMs, system integrators, and maintenance teams seeking scalable measurement capabilities without breaking the budget. With plug-and-play compatibility and straightforward software integration, this module helps you accelerate project timelines while delivering dependable measurement results across a wide range of industrial applications.

  • Two independent 32-bit counter input channels (Counter 0 and Counter 1) deliver high-resolution counting for precise event tracking, batch counting, or rate measurements, enabling you to capture even high-speed signals with reliability. The dual-channel design supports synchronous or independent counting, allowing versatile measurement strategies in process control, packaging lines, and encoder-based systems.
  • Built-in programmable timer supports flexible frequency measurement and time-based calculations, enabling you to derive signal frequency, period, duty cycle, and event timing without external timing hardware. This timer simplifies complex timing tasks, supports various measurement modes, and reduces system complexity and cost.
  • Cost-effective module that fits into standard Advantech backplanes or DAQ chassis, providing a scalable solution for expanding measurement capacity across multiple channels in a single system. Its modular architecture makes it easy to deploy in legacy or new installations, preserving your existing investments while enabling future upgrades.
  • Real-time monitoring of counter and frequency data as measurements are taken, with straightforward software integration to streamline data collection, logging, and alerting in industrial control scenarios. Operators gain immediate visibility into process dynamics, enabling faster decision-making and improved throughput.
  • Rugged, compact design with reliable operation in industrial environments, featuring robust signal conditioning options and straightforward installation, making it suitable for manufacturing floors, test benches, and lab automation. The module is designed to withstand vibration, temperature fluctuations, and electrical noise typical of factory settings.

Technical Details of Advantech 2-ch Counter/Frequency Module

  • Product: ADAM-4080 / 4080D Counter/Frequency Input Module
  • Channels: 2 (Counter 0 and Counter 1) for simultaneous counting and frequency measurement
  • Counters: 32-bit resolution to handle large event counts with high precision
  • Timer: Built-in programmable timer for flexible frequency measurement and timing applications
  • Input type: Counter and frequency input compatible with standard digital signals
  • Interface: Designed to integrate with Advantech backplanes and ADAM series data acquisition systems
  • Electrical characteristics: Optimized for low-noise counting and stable measurements in industrial environments
  • Physical design: Compact form factor suitable for dense server/ rack installations

How to install Advantech ADAM-4080/4080D

  • Power down the system and verify that your chassis or backplane is compatible with the ADAM-4080/4080D module before insertion. Confirm orientation and slot compatibility to avoid misalignment.
  • Power off and remove any existing modules if you are upgrading an existing rack, then firmly seat the ADAM-4080/4080D into the appropriate slot on the backplane, ensuring a secure connection to the backplane bus.
  • Connect your counter/frequency input signals to Counter 0 and Counter 1 using shielded cables, observing signal integrity and grounding best practices to minimize noise influence on counts and frequency measurements. Use proper termination for long runs or high-speed inputs when required.
  • Configure the module in your software or driver library: select the ADAM-4080/4080D, assign channel 0 and channel 1, and set the timer parameters (clock source, measurement mode, and sampling rate) to match your application needs. Validate that the software receives data from both counters and the timer.
  • Validate operation: apply a known test signal or pulse train, verify counts and frequency readings, and adjust input filtering or debounce settings as necessary to ensure stable data under real-world conditions. Document the configuration for future maintenance and audits.

Frequently asked questions

  • What is the Advantech ADAM-4080/4080D used for?

    The ADAM-4080/4080D is a two-channel counter and frequency input module designed for measuring event counts and signal frequency in automation, manufacturing, and test environments. With 32-bit counters and a programmable timer, it offers accurate timing and counting without external hardware.

  • What input signals does it support?

    The module accepts standard digital counter and frequency input signals, suitable for pulses from encoders, flow meters, tachometers, production line sensors, and other discrete-event sources. Ensure signal levels are within the module's specification and that proper conditioning is used for noisy environments.

  • Can I measure frequency with the built-in timer?

    Yes. The built-in programmable timer enables frequency measurement by sampling counts over a defined interval, from which you can derive instantaneous frequency, duty cycle, and period. You can also use the timer for time-stamped event counting and interval timing.

  • How do I configure the counters in software?

    In your software or driver library, select ADAM-4080/4080D, enable Counter 0 and Counter 1, configure the timer source and measurement mode, and set any input conditioning or debounce settings required to stabilize readings. Monitor the outputs in real time and log data as needed.

  • Where can I find specifications and compatibility details?

    Specification details, electrical characteristics, and compatibility information are available from the manufacturer’s datasheets and the distributor’s product page, including the ec.synnex.com reference for UPC or SKU. Always consult the official spec sheets to ensure correct integration with your system.