Description
The APC Basic Rack PDU 3.68kVA 230V is a purpose-built, cost-efficient power distribution solution designed to keep critical rack-mounted equipment powered with simplicity and reliability. Engineered to integrate seamlessly with NetShelter VX enclosures, this PDU delivers essential outlets and clean cable management without unnecessary complexity. It offers scalable power distribution that grows with your rack environment, making it an ideal choice for data centers, IT rooms, and office server closets where uptime, space, and budget matter. With a 3.68 kVA rating, it provides ample headroom to power multiple devices—from servers and switches to storage and networking gear—while maintaining front-of-rrack clearance and organized power delivery. This is the practical, dependable option for businesses seeking dependable power distribution without the overhead of high-end, feature-rich PDUs.
- Cost-effective power distribution for NetShelter VX enclosures, designed to maximize uptime and operational efficiency without overspending on complex power solutions.
- 3.68 kVA capacity at 230V with a 16A circuit, providing sufficient headroom to support several rack devices simultaneously in standard deployments.
- Outlet configuration featuring 20 IEC 60320 C13 outlets and 4 IEC 60320 C19 outlets, enabling flexible provisioning for a mix of rack equipment and future expansion.
- Toolless mounting in the rear channel of NetShelter VX, allowing quick, tool-free installation and easy repositioning as rack layouts evolve.
- Vertical mounting in NetShelter VX rear channels optimizes front clearance and cable management, helping maintain a tidy rack environment with reliable power distribution for critical devices.
Technical Details of APC Basic Rack 3.68kVA PDU
Note: Specifications are not provided in the current listing. The model name indicates a 3.68kVA capacity and vertical, tool-less mounting in a NetShelter VX rear channel. This section highlights the documented emphasis on power distribution to rack equipment and compatibility with APC NetShelter VX environments. For precise technical details such as input/output configurations, cord lengths, and exact outlet counts, consult official product sheets or the supplier’s specifications when available.
- Capacity: 3.68 kVA (approximately 16A at 230V)
- Input voltage: 230V AC
- Current rating: 16A
- Outlet count and type: 20 x IEC 60320 C13 outlets; 4 x IEC 60320 C19 outlets
- Outlet organization: Designed to deliver distributed power to rack-mounted devices with clean, organized cabling
- Mounting: Vertical PDU with rear-channel, tool-less mounting compatible with NetShelter VX enclosures
- Mounting method: Toolless rear-channel installation for quick deployment and flexible positioning
- Compatibility: Optimized for NetShelter VX environments to maintain front clearance and streamlined cable management
How to Install APC Basic Rack PDU
- Prepare the NetShelter VX enclosure and confirm that your site supply is 230V and the circuit is rated for 16A. Switch off power to the rack area before beginning installation.
- Remove any required rear-channel covers or clearance obstacles in the NetShelter VX enclosure to enable the PDU’s vertical, rear-channel mounting.
- Align the APC Basic Rack PDU with the NetShelter VX rear channel and slide it into place. The tool-less mounting should engage with a tactile feel when properly seated.
- Securely position the PDU in the rear channel and verify that it is firmly mounted with no wobble or misalignment. Recheck that there is adequate front clearance for cables and airflow.
- Connect the PDU’s input power cord to the 230V power source. Route the outlet cables from the C13 and C19 outlets to your rack devices, keeping cables tidy and labeled for easy maintenance and future changes.
- Power on the cabinet and verify that each outlet is delivering power to connected devices. If needed, label circuits and outlets to simplify ongoing management and troubleshooting.
Frequently asked questions
-
What outlets are available on the APC Basic Rack PDU?
The unit provides 20 IEC 60320 C13 outlets and 4 IEC 60320 C19 outlets, offering flexible power distribution for servers, switches, storage, and networking gear. -
What is the input voltage and current rating?
The PDU operates at 230V AC with a 16A current rating, aligning with common data-center and IT room power standards. -
Is this PDU compatible with NetShelter VX enclosures?
Yes. It is specifically designed for vertical, rear-channel mounting within NetShelter VX enclosures, promoting front clearance and clean cable management. -
Do I need tools to install this PDU?
No. The APC Basic Rack PDU features tool-less mounting in the NetShelter VX rear channel for quick, hassle-free installation and easy reconfiguration as needs change. -
Can the PDU support growing IT environments?
With a 3.68 kVA capacity and multiple outlet configurations, it provides scalable power distribution suitable for expanding rack deployments without major up-front investments. -
What should I consider for cable management?
Plan outlet usage to minimize cable clutter, route power cords away from airflow paths, and label circuits to simplify monitoring and maintenance over time.