APC Basic Rack 4.992kVA PDU
The APC Basic Rack 4.992kVA PDU is a dependable, high‑efficiency power distribution unit designed to protect and power your essential IT infrastructure. Built for reliability in data centers, server rooms, wiring closets, and equipment racks, this PDU delivers scalable, cost‑effective power distribution with a focus on uptime and growth. It combines robust construction with practical, rack‑friendly connectivity, making it an ideal choice for organizations seeking to optimize energy use, simplify cable management, and maintain uninterrupted operation across critical devices. With its NEMA locking outlets and a versatile NEMA L14‑30P input, this basic PDU provides the flexibility to match a variety of electrical setups while keeping surge protection, power sequencing, and monitoring simple and accessible.
- High‑capacity power distribution: The APC Basic Rack PDU is built to support demanding workloads with a 4.992 kVA rating, giving you ample headroom to power multiple servers, switches, storage devices, and network gear within a single rack. This capacity helps reduce the need for additional PDUs and simplifies circuit planning, enabling your data center to scale smoothly as your infrastructure grows.
- NEMA L5‑20R outlets for secure, locking connections: The PDU features NEMA L5‑20R receptacles designed to provide locking, vibration‑resistant connections. This design minimizes accidental unplugging and helps maintain continuous operation in environments where equipment is subject to movement, airflow, or rearrangement within the rack. Locking outlets also improve reliability for critical devices that demand stable powerfeed without interruptions.
- NEMA L14‑30P input for flexible power configuration: The L14‑30P plug/connector supports higher amperage circuits and accommodates 125/250V operations, offering flexibility to align with your facility’s electrical infrastructure. This input configuration makes it easier to connect the PDU to diverse power sources while accommodating future changes in your data center layout or power strategy.
- Rack‑mountable, 19‑inch form factor: Designed for standard 19‑inch server racks, this PDU integrates cleanly into existing cabinets with minimal space impact. Its compact, sturdy build helps maintain good airflow and neat cable organization, which are key to thermal management and ease of maintenance in busy data centers and wire rooms.
- Cost‑effective, scalable power distribution: As a basic, reliable PDU from a trusted brand, it delivers essential power management without unnecessary complexity. This makes it an excellent choice for wiring closets, smaller data centers, or environments that demand dependable uptime and straightforward expansion as your IT footprint grows.
Technical Details of APC Basic Rack 4.992kVA PDU
- Capacity: 4.992 kVA
- Input connector: NEMA L14‑30P plug/connector
- Output receptacles: NEMA L5‑20R locking outlets
- Form factor: Rack‑mountable 19" enclosure
- Mounting: Standard 19" rack rails for secure installation with appropriate mounting hardware
how to install APC Basic Rack 4.992kVA PDU
- Prepare the rack and power sources: Verify that your rack space is clear of obstructions and that the available electrical circuit matches the input requirements of the PDU. Confirm that the main power source can support the PDU’s input draw and that there is enough clearance for cable management and cooling around the rack area.
- Mount the PDU in the rack: Remove any packaging from the PDU and align it with the rack rails. Secure the unit using the appropriate screws and mounting hardware designed for 19" racks. Ensure the PDU sits firmly and is level to avoid any strain on cables or connectors and to preserve proper airflow behind the unit.
- Connect the input plug: Plug the NEMA L14‑30P input connector into a suitable, protected power source that matches the PDU’s input rating. If using a power distribution circuit with breakers, ensure the breaker is sized for the PDU’s maximum load and that all safety protocols are followed before energizing the system.
- Plug in devices and organize cables: Connect servers, switches, storage appliances, and other equipment to the NEMA L5‑20R outlets on the PDU. Use cable ties or organizers to keep cables tidy and to avoid obstructing airflow around air vents and fans inside the rack. Distribute loads evenly across outlets to prevent overload on any single branch.
- Power on and verify operation: After connecting equipment, power on the main circuit and monitor the PDU indicators or connected devices for normal operation. Check that all outlets are delivering power and that connected equipment boots up correctly. If the PDU offers load indicators or PWM features, use them to confirm an even distribution of power and to spot any imbalances early.
Frequently asked questions
- Q: What is the capacity of the APC Basic Rack 4.992kVA PDU? A: It is rated at 4.992 kVA, providing substantial headroom for powering multiple servers and networking devices within a standard 19" rack.
- Q: What outlets does this PDU use? A: The unit uses NEMA L5‑20R locking outlets for secure, reliable connections to critical equipment.
- Q: What is the input plug type? A: The PDU features a NEMA L14‑30P input plug/connector, enabling compatibility with higher‑amperage circuits and flexible power configurations.
- Q: Is the PDU compatible with standard 19" racks? A: Yes. It is designed for standard 19" rack mounting, making it easy to install in most data centers, server rooms, and wiring closets.
- Q: How does this PDU help with uptime and efficiency? A: By providing a robust, locking connection for critical devices, clear load distribution, and a scalable power delivery solution, the APC Basic Rack PDU reduces downtime risks and supports energy‑efficient operation across the rack ecosystem, helping you manage growth without compromising reliability.