APC Basic Rack 7360VA PDU


Price:
Sale price$719.27

Description

APC Basic Rack 7360VA PDU — Vertical, Tool-Less Rack Power Distribution for NetShelter VX

APC Basic Rack 7360VA PDU offers essential, dependable power distribution for rack-mounted equipment. Designed for NetShelter VX enclosures, this basic PDU provides a single input power source and can be mounted vertically in the rear channel, freeing valuable front chassis space for equipment visibility and airflow. It combines straightforward, robust design with practical overload protection through resettable circuit breakers, delivering reliable operation in data center, server room, and edge environments. Whether you are outfitting a new rack or upgrading an existing setup, this PDU helps simplify power management while safeguarding critical devices against unexpected outages. With a focus on simplicity and value, the 7360VA PDU is ideal for organizations seeking a cost-effective solution that delivers dependable power distribution without the complexity of advanced network management.

  • Power capacity and distribution: The APC Basic Rack 7360VA PDU delivers a substantial total power capacity to support multiple high-demand devices from a single source. This reliable distribution unit keeps servers, switches, storage arrays, and other rack equipment energized consistently, helping to balance loads across circuits and reduce the risk of nuisance outages during peak operation.
  • Vertical, tool-free mounting in NetShelter VX rear channel: Built to blend with NetShelter VX enclosures, the PDU slides into the rear channel and locks in without tools. This design saves installation time, preserves front-panel clearance, and promotes better airflow by minimizing clutter behind the rack.
  • Single input power source: The PDU is designed to be powered from a single input source, simplifying electrical planning and cabling. With one dependable feed, you can organize outlets efficiently, ensuring your critical devices have reliable access to power while keeping branch circuit loads manageable.
  • Resettable circuit breakers for quick recovery: Overloads are easily managed with resettable breakers that trip to protect connected equipment and can be reset after reducing load. This feature minimizes downtime in busy data centers and eliminates the need for fuse replacement during routine maintenance.
  • Rugged, enterprise-ready design and serviceability: The Basic Rack 7360VA PDU is built to endure data center conditions. It resists temperature variations, supports ongoing operation under typical loads, and is straightforward to service, making it a practical choice for IT teams seeking dependable, straightforward power distribution that won’t break the bank.

Technical Details of APC Basic Rack 7360VA PDU

  • Power rating: 7360 VA total capacity.
  • Mounting: Vertical rear-channel installation designed for NetShelter VX enclosures.
  • Input: Single input power source.
  • Protection: Resettable circuit breakers for overload protection and quick recovery.
  • Purpose: Distributes power to multiple rack-mounted devices from a single feed.

How to install APC Basic Rack 7360VA PDU

Before you begin, verify compatibility with your NetShelter VX enclosure and ensure the rear channel is clean and accessible. Power down all equipment and unplug devices as a safety precaution to prevent any electrical hazards during installation.

Slide the PDU into the vertical rear-channel rails. The tool-less mounting design allows you to secure the PDU without tools, aligning with the NetShelter VX rails for a snug fit. Confirm that the unit sits flush against the rails and that it nests securely in place to avoid movement during operation.

Secure the PDU to the rails using the built-in mounting features. Ensure both ends are properly engaged in the channels and that there are no loose fittings. A secure mounting helps prevent vibrations and contributes to reliable electrical distribution, especially in busy data centers with high airflow.

Connect the PDU’s input power cord to a suitable single input power source. Make sure the electrical configuration matches the PDU’s rating and adheres to local electrical codes. Use a properly rated power cord and route it away from heat sources and moving parts to minimize wear and potential tripping hazards.

Route rack devices’ power cords to the PDU outlets, label important circuits, and resume power. Distribute loads evenly across outlets to maintain balanced current draw and reduce the risk of overheating. Power up and test each connected device to confirm proper function and ensure the resettable breakers are ready to protect against overloads.

Frequently asked questions

  • Q: Is the APC Basic Rack 7360VA PDU compatible with NetShelter VX enclosures? A: Yes. It is designed for vertical mounting in the NetShelter VX rear channel, enabling a tool-free installation and seamless integration with existing rack configurations.
  • Q: What is the total power capacity of this PDU? A: The unit provides a total capacity of 7360 VA, suitable for distributing power to multiple rack devices from a single input source.
  • Q: Does this PDU include advanced network management features? A: This is a basic rack PDU focused on straightforward power distribution and overload protection. It does not include built-in network management capabilities; additional management options would require separate modules or devices.
  • Q: How do I reset a tripped breaker? A: Resettable circuit breakers allow quick recovery. When a breaker trips, reduce the load as needed, then reset the breaker to restore power to connected equipment and verify operation.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed