APC by Schneider Electric ACF600 NetShelter Fan Tray
The APC by Schneider Electric ACF600 NetShelter Fan Tray is a vital upgrade for data centers and IT rooms that rely on dense rack configurations. Engineered to deliver targeted airflow, this high-performance accessory enhances cooling effectiveness where hot spots typically form around power-dense equipment. In NetShelter enclosures, the ACF600 helps maintain consistent temperatures, reduce thermal throttling, and extend the life of critical servers, storage, and networking gear. Built to withstand the demands of 24/7 operation, it integrates smoothly with APC NetShelter racks, offering a reliable solution for improving rack-level cooling without the need for a full-scale cooling overhaul. Whether you’re expanding a data center footprint or optimizing a high-density rack environment, the ACF600 NetShelter Fan Tray delivers the airflow you need for steady, efficient performance.
- Up to 600 CFM of front-to-back airflow helps relieve hotspots in high-density racks. This robust airflow distribution targets critical components such as CPUs, GPUs, and storage controllers, supporting sustained performance under load.
- Seamless NetShelter compatibility and easy installation. Designed to integrate with APC NetShelter enclosures and standard 19-inch racks, the ACF600 installs quickly in open spaces, with secure mounting that maintains orderly cable management and airflow pathways.
- Energy-efficient operation with a low noise footprint. Built to minimize power draw while maximizing cooling impact, it supports data center efficiency goals and reduces the acoustic impact in office- or data-center-adjacent spaces.
- Durable, service-friendly design. The rugged construction withstands the rigors of continuous operation in data centers, with straightforward access for maintenance or component replacement to keep downtime to a minimum.
- Supports hot aisle/cold aisle cooling strategies and improved rack-level control. By enhancing airflow distribution within the rack, it complements broader cooling architectures and helps maintain uniform temperatures across multiple devices.
Technical Details of APC by Schneider Electric ACF600 NetShelter Fan Tray
- Airflow capacity: Up to 600 CFM (model-dependent)
- Electrical: 120 V AC nominal, 60 Hz (typical for many regions)
- Power consumption: Designed for energy-efficient operation (consumption varies with speed and load)
- Mounting: Standard 19-inch rack compatibility; designed for NetShelter enclosures
- Form factor: Front-to-back cooling design compatible with common data-center rack configurations
- Construction: Robust housing designed to endure continuous operation in data centers
- Warranty and support: Backed by Schneider Electric product warranties; regional terms apply
how to install APC by Schneider Electric ACF600 NetShelter Fan Tray
- Power down gear and disconnect power from the rack before starting installation to ensure safety and prevent equipment damage.
- Identify an available 19-inch space in the NetShelter enclosure where front-to-back airflow is desired. Plan airflow paths to align with the existing hot and cold aisles for maximum cooling efficiency.
- Align the fan tray with the rack rails and secure it using the included mounting hardware. Ensure the unit sits firmly and does not interfere with cabling or front-panel access.
- Connect the power cable to a grounded 120 V AC outlet and verify the unit powers on. Confirm that the fans begin to rotate freely without obstruction.
- Configure any speed controls or mode settings if provided on the unit. Check for smooth operation and ensure there are no unusual noises or vibrations after installation.
- Power on connected equipment and monitor rack inlet temperatures to confirm improved airflow. Make small adjustments to placement or speed as needed to optimize cooling for your specific rack load.
Frequently asked questions
Q: What is the primary purpose of the ACF600 NetShelter Fan Tray?
A: The ACF600 is designed to enhance air distribution inside high-density racks, increasing cooling efficiency and reducing hot spots around power-dense servers, storage arrays, and networking gear. This helps maintain stable operating temperatures and protect performance.
Q: Which racks are compatible with the ACF600?
A: It is engineered for use with APC NetShelter enclosures and standard 19-inch racks. The mounting is built to integrate smoothly with typical data-center rack configurations, supporting flexible deployment within existing environments.
Q: How does the ACF600 contribute to energy efficiency?
A: By delivering targeted, high-volume airflow where it is most needed, the ACF600 can reduce the workload on other cooling resources and improve overall cooling efficiency. This can help lower energy consumption associated with maintaining safe operating temperatures in dense racks while minimizing noise impact.
Q: What maintenance is required for long-term reliability?
A: The fan tray is designed for durability in 24/7 data-center conditions. Routine checks should include verifying airflow, listening for unusual noises, and ensuring mounting hardware remains tight. Filters or grills (if equipped) should be inspected and cleaned per the product’s maintenance guidelines, and any worn components should be replaced promptly to maintain optimal performance.
Q: Do I need to upgrade other cooling components when adding the ACF600?
A: In many cases, the ACF600 complements existing cooling systems by improving rack-level airflow and reducing hotspots. For extensively dense deployments or environments with marginal cooling, you may want to review overall air distribution, front-to-back airflow paths, and ambient room cooling in concert with your data-center cooling plan to achieve best results.