Apc By Schneider Electric Apc Netshelter Rack Pdu Advanced, Metered Outlet, 3ph, 17.3kw, 208v, 60a, 460p9,


Price:
Sale price$4,510.61

Description

Apc Netshelter Rack PDU Advanced – 3-Phase Metered Outlet, 17.3 kW, 208V, 60A (460P9)

Meet the APC by Schneider Electric Netshelter Rack PDU Advanced, a premier power distribution solution engineered for modern data centers, network closets, and edge deployments. This 3-phase, metered PDU delivers precise energy management, robust protection, and scalable capacity to support dense server and network workloads. With an impressive 17.3 kW maximum power at 208V and a 60A input, the 460P9 configuration is built to sustain critical equipment while simplifying infrastructure management. Designed for seamless integration with APC Netshelter enclosures and other compatible 19-inch rack systems, it helps administrators optimize uptime, monitor consumption, and forecast future power needs with confidence.

  • Real-time power visibility and phase balancing: The Advanced PDU provides detailed metering across all three phases and downstream outlets, enabling you to monitor current, voltage, and apparent power in real time. This visibility helps prevent overloads, identify imbalances, and fine-tune load distribution to keep your critical IT gear performing at peak efficiency.
  • Three-phase efficiency for high-density deployments: Operating at 208V and delivering up to 17.3 kW with a 60A input, this PDU is optimized for modern, high-density racks. Three-phase distribution reduces voltage drop, improves power quality, and minimizes wasted energy—translating into cooler racks and lower cooling costs over time.
  • Metered outlet configuration for granular control: The meter-enabled output lets data center operators track consumption by branch or circuit, supporting precise capacity planning, cost allocation, and proactive maintenance. You gain actionable insights to optimize workloads and reduce electricity waste without sacrificing uptime.
  • Rugged, rack-ready design: Built to endure demanding data-center environments, the Netshelter Rack PDU Advanced supports secure mounting in APC Netshelter enclosures and compatible 19-inch racks. Its robust construction, integrated cable management, and labeling capabilities simplify installation, auditing, and ongoing management while preserving airflow and accessibility.
  • Seamless management and future-proof flexibility: The PDU is designed for easy integration with APC management tools and DCIM ecosystems. By combining local metering data with remote monitoring, you can automate alerts, track energy trends, and scale your power strategy as your IT footprint grows, ensuring your infrastructure remains resilient and ready for expansion.

Technical Details of APC Netshelter Rack PDU Advanced

  • Model: 460P9
  • Power configuration: 3-phase, 208V input/output
  • Current rating: 60A
  • Total capacity: 17.3 kW
  • Metering: Metered outlet with real-time energy monitoring
  • Mounting compatibility: Designed for APC Netshelter racks and standard 19-inch cabinets
  • Protection features: Built-in safeguards and labeling to support safe installation and operation

How to install APC Netshelter Rack PDU Advanced

  • Plan your rack space and load distribution by identifying which devices will connect to the PDU’s metered outputs, ensuring you stay within the 60A rating and desired kW capacity.
  • Prepare the rack cabinet and confirm the enclosure is properly grounded, ventilated, and accessible for cable management and maintenance.
  • Mount the PDU securely in the APC Netshelter rack or compatible 19-inch cabinet, following the provided installation instructions and ensuring stable, vibration-free mounting.
  • Connect the PDU input to the facility power source or UPS according to local electrical codes. Verify all connections are tight and compliant with safety standards before energizing the system.
  • Route IT loads to the PDU’s metered outputs with clear labeling and organized cables to maximize airflow and simplify future replacements or service work. Power on and verify operation.
  • Access the PDU’s local display (or management software) to configure metering parameters, alarms, and remote monitoring settings. Run a load test to confirm balanced distribution across all phases and ensure accurate energy reporting.

Frequently asked questions

  • Q: What voltage and phase configuration does this PDU support?

    A: The APC Netshelter Rack PDU Advanced is a 3-phase device operating at 208V, designed to deliver high-density power distribution for modern data centers.

  • Q: What does “metered outlet” mean?

    A: A metered outlet provides real-time energy data for the connected loads, enabling precise monitoring of power usage, better capacity planning, and more accurate cost allocation across racks.

  • Q: Is this PDU compatible with non-APC racks?

    A: It is designed for APC Netshelter enclosures but is also suitable for standard 19-inch racks that meet mounting and clearance requirements specified by the installation guide.

  • Q: How can I monitor power remotely?

    A: You can monitor energy usage locally via the PDU’s display and remotely through APC management software or compatible DCIM tools, which provide alerts, trends, and reporting for your entire data center.

  • Q: What kind of maintenance is recommended?

    A: Regular checks should include verifying connections, inspecting for signs of wear or overheating, confirming metering accuracy, and updating any firmware or management configurations as recommended by Schneider Electric.