APC by Schneider Electric AR7715 NetShelter SX Side Air Flow Duct Kit


Price:
Sale price$477.98

Description

The APC AR7715 NetShelter SX Side Air Flow Duct Kit is engineered to optimize cooling in densely populated NetShelter SX enclosures by directing front-to-side airflow for side-mounted equipment such as networking switches. This kit helps balance temperature across critical devices, improves cooling efficiency, and reduces hot spots in data centers and network cages. By channeling cool air precisely where it’s needed, it supports reliable performance, longer equipment life, and quieter operation, even under heavy workloads. The AR7715 integrates smoothly with existing NetShelter SX infrastructure, making it a smart choice for IT managers seeking to maximize rack capacity without compromising thermal management.

  • Targeted cooling for side-mounted devices: The kit includes two 2U ducts that sit in the u-space directly above and below the equipment. This setup draws front air through the device intakes and distributes it efficiently to the side-facing components, helping networking switches and other side-mounted gear stay within optimal temperature ranges—even during peak traffic. By focusing airflow where it’s most needed, you minimize hotspots and maintain consistent performance across ports and modules.
  • Front-to-side airflow design for dense racks: The AR7715 channels cooling air from the enclosure front into the intake of side airflow equipment. The dual-duct arrangement provides uniform air distribution across multiple devices in a compact footprint, reducing cross-duct temperature variation and supporting stable operation for devices with varying thermal loads.
  • Seamless NetShelter SX integration: Specifically engineered for APC NetShelter SX enclosures, this duct kit fits the standard dimensions and mounting patterns of the SX family. It preserves accessible front and rear cabling areas, maintains clearance for cable management, and preserves the enclosure’s overall usability while delivering enhanced airflow performance in challenging deployments.
  • Airflow containment with a side baffle: A dedicated side baffle works in concert with the ducts to keep guided air on target. By preventing leakage and stray airflow, the side baffle helps maintain a stable cooling path for side-mounted devices, allowing the fans inside the enclosure to operate more efficiently and quietly. This containment translates to better predictability of temperatures and more consistent device performance.
  • Reliability, efficiency, and easy maintenance: With improved cooling efficiency come benefits such as reduced thermal stress on critical components and potential energy savings from lower fan speeds. The AR7715 is designed for straightforward installation and ongoing reliability, minimizing downtime during upgrades or expansions and keeping your data center or edge deployment running smoothly.

Technical Details of APC by Schneider Electric AR7715 NetShelter SX Side Air Flow Duct Kit

  • Compatibility: Fits APC NetShelter SX enclosures.
  • Includes: Two 2U side air flow ducts and a side baffle for airflow containment.
  • Airflow direction: Front of the enclosure to the intake of side-mounted equipment.
  • Placement: Ducts mount in the u-space directly above and below the installed equipment.
  • Purpose: Improves cooling efficiency for side-mounted networking gear in dense rack environments.

how to install APC by Schneider Electric AR7715 NetShelter SX Side Air Flow Duct Kit

Installing the AR7715 Side Air Flow Duct Kit is designed to be straightforward and minimally disruptive. Follow these steps to maximize cooling performance without compromising access for maintenance or cabling:

  • Step 1: Power down and prepare: Before beginning, power down all equipment inside the enclosure and remove any front doors or obstructing panels if required. Ensure you have clear access to the u-space where the equipment is mounted and identify the two 2U locations above and below the devices.
  • Step 2: Position the ducts: Align the two 2U ducts with the u-space above and below the equipment. The ducts are designed to slide into standard 19-inch rack rails, so align them with the existing rail tracks and ensure they are level for proper airflow alignment.
  • Step 3: Attach the ducts: Secure the ducts to the rails using the provided mounting hardware. Confirm that the duct outlets align with the side-facing equipment’s intake areas to ensure efficient front-to-side airflow. Tighten fasteners to a secure fit without over-torquing.
  • Step 4: Install the side baffle: Position the side baffle along the enclosure side adjacent to the duct outlets. The baffle should align with the duct outlets to prevent air from escaping to the exterior and to maintain a focused cooling path toward the side-mounted devices.
  • Step 5: Route cables and test: Reorganize and secure cables to ensure unobstructed airflow. Replace any doors or panels, restore power, and observe airflow through the ducts. Verify that front-to-side airflow is reaching the intended devices and monitor temperatures to confirm improved cooling performance.

Frequently asked questions

  • Q: What enclosure is compatible with AR7715? A: The AR7715 is designed specifically for APC NetShelter SX enclosures and should be used within those rack systems to achieve optimal airflow.
  • Q: What devices benefit most from this kit? A: Side-mounted devices such as networking switches, small form-factor servers, and other equipment installed in the SX enclosure that rely on front-to-side intake airflow benefit most, especially in high-density racks.
  • Q: Does installing AR7715 require any enclosure modification? A: No permanent enclosure modifications are required. The kit mounts within the existing u-space rails and uses standard mounting hardware to maintain the enclosure’s integrity.
  • Q: Will this kit reduce fan noise? A: By improving airflow efficiency and reducing hotspots, the kit can contribute to more stable temperatures, which may allow fans to run at lower speeds in some configurations, potentially reducing noise.
  • Q: Is maintenance easier after installation? A: Yes. The kit is designed to preserve accessible cabling and serviceability while optimizing airflow paths, making routine maintenance and future upgrades smoother.