APC by Schneider Electric Circuit Breaker Adaptor


Price:
Sale price$737.02

Description

Power distribution unit accessories make expanding your data center power distribution quick and easy. APC's power distribution accessories deliver the flexibility and management that data centers require. By providing a comprehensive selection of single- and three-phase whips, breakers, connectors, and related components, the APC by Schneider Electric Circuit Breaker Adaptor helps you scale your infrastructure with confidence. This adaptor is designed to integrate seamlessly with APC PDUs, enabling safer, more organized power distribution for growing workloads, high-density racks, and mission-critical applications. If you’re building out a robust data center or upgrading an existing deployment, the circuit breaker adaptor offers modularity, streamlined maintenance, and improved electrical protection—key factors in maximizing uptime and efficiency.

  • Flexible power distribution configuration: Supports both single-phase and three-phase setups, giving you the versatility to match diverse load profiles across racks and zones. This adaptability helps optimize wiring efficiency and reduces the need for overprovisioning, so you can deploy precisely what your data center needs.
  • Modular, scalable design for growing environments: Built to accommodate expanding infrastructure, the adaptor pairs with APC PDUs and a broad family of breakers and connectors. As your data center scales, you can add or reconfigure components without a complete redesign of your power distribution layout.
  • Simple installation and quick integration: Engineered for straightforward installation with APC’s established connector standards. The adaptor minimizes downtime during upgrades and reconfigurations by supporting fast, secure connections and clean cable management.
  • Reliable protection and safer cable management: By enabling the use of dedicated breakers and properly routed connectors, the circuit breaker adaptor enhances electrical protection and reduces clutter. Organized cabling improves airflow, simplifies maintenance, and lowers the risk of accidental disconnections or short circuits in dense rack environments.
  • Designed for APC PDU ecosystem compatibility: As an official APC accessory, it integrates with APC power distribution products, ensuring compatibility, reliability, and consistent performance across your data center power architecture. This integration helps simplify monitoring, maintenance, and future upgrades.

Technical Details of APC by Schneider Electric Circuit Breaker Adaptor

  • Product Type: Circuit Breaker Adaptor for APC PDU systems
  • Compatibility: APC by Schneider Electric Power Distribution Units (PDUs) and modular power distribution setups
  • UPC/SKU: Not available in the provided product details
  • Configuration Support: Single-phase and three-phase configurations with compatible whips, breakers, and connectors
  • Material/Construction: Durable materials designed for demanding data center environments
  • Certifications: Not specified in the available product details

How to Install APC by Schneider Electric Circuit Breaker Adaptor

Follow these general steps to install the adaptor with compatible APC PDUs. Always observe your site’s safety procedures and power-down protocols before working with live electrical equipment:

1) Power down and lock out the affected PDU and any connected equipment. Verify that all sources of power to the rack area are isolated before beginning work.

2) Remove the panel or access cover as required by your APC PDU model to expose the breaker connection area and available ports for adaptor installation.

3) Inspect the adaptor and associated breakers to ensure there are no visible signs of damage. Confirm that you have the correct single-phase or three-phase configuration for your specific load requirements.

4) Align the adaptor with the designated APC PDU connectors and slide or snap it into place according to the product’s installation guidelines. Ensure all connectors are fully seated and secure with any required fasteners or retention features.

5) Attach the appropriate breakers and whips (single-phase or three-phase) to the adaptor, following the current rating and wiring scheme specified for your load. Route cables neatly to promote airflow and prevent interference with other components.

6) Reattach the PDU cover or panel, restore power, and perform a cautious power-on test. Verify that the new configuration is recognized by any monitoring systems and that each breaker provides proper protection for its respective circuit.

7) Label the modified circuit paths clearly and update documentation to reflect the new breaker adaptor configuration. Regularly inspect connections and ensure that all safety standards are maintained during future maintenance or upgrades.

Frequently asked questions

  • What is the APC Circuit Breaker Adaptor used for? It serves as a modular accessory that enables flexible, scalable protection and connection options for APC PDUs. By interfacing with breakers and connectors, it supports safe, organized power distribution across a data center floor or rack environment.
  • Is this adaptor compatible with all APC PDUs? The adaptor is designed to work with APC by Schneider Electric PDUs and related power distribution components. For exact model compatibility, refer to your PDU’s documentation and the adaptor’s installation guidelines.
  • Does the adaptor support both single-phase and three-phase configurations? Yes. It is designed to accommodate single-phase and three-phase setups, allowing you to tailor the configuration to your specific workload and electrical infrastructure.
  • What are the benefits of using a circuit breaker adaptor in a data center? Benefits include expanded flexibility for power distribution, safer and more reliable electrical protection, improved cable management, easier upgrades, and better alignment with scalable data center growth.
  • Are there any installation considerations I should know? Typical considerations include ensuring power is fully shut down before installation, verifying load requirements and breaker ratings, and following APC’s installation guidelines to maintain safety, compliance, and warranty validity.