Description
Engineered to maximize availability in Row and Room cooling configurations, the APC air-cooled condenser delivers a scalable, reliable solution for small to medium data centers. This system-matched condenser works in harmony with APC cooling modules to form a complete, turnkey solution that simplifies design, deployment, and ongoing operation. Built to handle dynamic data-center loads, it supports both fixed and variable speed fan configurations to optimize performance, energy efficiency, and uptime. With its 88 kW cooling capacity and a design that anticipates modern data center requirements, this condenser is crafted to help maintain precise temperatures, improve reliability, and minimize the risk of thermal bottlenecks in critical environments.
- High-capacity cooling for demanding workloads — 88 kW of reliable cooling capacity designed to maintain optimal temperatures under mission-critical conditions, delivering consistent performance for small to mid-sized data centers.
- Flexible fan options for load matching — Available with fixed-speed or variable-speed fans to adapt to changing cooling requirements, enabling energy efficiency and quieter operation when loads are lighter.
- System-matched with Row and Room cooling — Specifically designed to integrate with APC Row and Room cooling products, providing a cohesive, optimized data-center cooling ecosystem with streamlined controls and monitoring.
- Rugged, data-center-ready design — Built to endure the demands of data-center environments, with components and construction focused on reliability, ease maintenance, and long-term performance.
- Electrical compatibility for common data-center power — Engineered for 208-230V three-phase, 60 Hz electrical systems, aligning with typical data-center electrical infrastructure for straightforward integration.
Technical Details of APC by Schneider Electric Condenser 88kW
- Cooling capacity: 88 kW (approx. 299,000 BTU/h) under design conditions for data-center workloads.
- Design conditions: accommodates heat rejection with 95°F / 120°F operating design considerations.
- Electrical requirements: 208-230V, 3-phase, 60 Hz input to support standard data-center power distribution.
- Fan configuration: available with fixed-speed or variable-speed fans, enabling tailored performance and energy efficiency.
- Type: air-cooled condenser designed for system-matched integration with APC Row and Room cooling solutions.
- Enclosure and build: rugged construction suitable for data-center environments with accessible service areas and straightforward maintenance access.
how to install APC by Schneider Electric Condenser 88kW
- Plan installation in a location with adequate clearance for intake, exhaust, service access, and routine maintenance, while ensuring proper airflow patterns.
- Verify electrical compatibility and safety requirements: provide 208-230V three-phase 60 Hz power, proper grounding, and appropriate protective devices per local electrical codes.
- Coordinate integration with APC Row and Room cooling modules, including control wiring for fan speed modes and system interlocks to ensure seamless operation and centralized monitoring.
- Configure fan operation to match the cooling load: choose fixed-speed for simplicity or variable-speed fans for energy efficiency and noise management in fluctuating environments.
- Perform commissioning and validation: power up the system, confirm airflow, verify temperature targets under representative loads, and ensure alarms and protections are functioning correctly.
Frequently asked questions
- Q: What is the cooling capacity of the APC condenser? A: It provides 88 kW of cooling capacity at design conditions for reliable data-center cooling.
- Q: What electrical supply does it require? A: It is designed for 208-230V, three-phase, 60 Hz power systems, compatible with common data-center electrical infrastructure.
- Q: Are fixed-speed and variable-speed fans available? A: Yes, the condenser can be equipped with fixed-speed or variable-speed fans depending on the model and application needs.
- Q: Is this condenser suitable for Row and Room data-center cooling? A: Yes, it is designed to be system-matched with APC Row and Room cooling solutions to deliver a complete, integrated cooling solution.
- Q: What maintenance and monitoring options are available? A: The condenser is built for ease of maintenance and integrates with APC monitoring and control ecosystems to support proactive management and rapid fault isolation.