The APC by Schneider Electric Galaxy VS 10kVA Tower UPS is a highly efficient, modular 3-phase power protection platform engineered for edge deployments, small to medium data centers, and other business-critical applications. Designed to scale from 20 to 100 kW at 480 V, 10 to 150 kW at 400 V, and 10 to 50 kW at 208 V, Galaxy VS delivers robust, double-conversion protection with a compact tower footprint that fits tight spaces without compromising uptime. This modular solution combines ease of deployment with field-replaceable components, enabling rapid maintenance, effortless growth, and confident protection for sensitive IT equipment, networking gear, and storage systems. Whether you are protecting a handful of critical servers at the edge or expanding to support a growing data center, Galaxy VS provides a reliable, future-ready power platform that helps you maintain continuous operations, optimize energy use, and simplify management across distributed IT environments.

  • Modular, scalable architecture for growth and redundancy - Galaxy VS is built as a flexible power platform where UPS modules, battery cabinets, and control units can be added or exchanged without interrupting critical loads. This modular approach supports N+X redundancy and makes it straightforward to scale from 20 kW up to 100 kW at 480 V, or expand across 400 V and 208 V configurations as your IT footprint evolves. With simple field upgrades, you can align power capacity with demand, ensuring high availability for core applications while preserving capital efficiency and minimizing downtime during growth or refresh cycles.
  • Advanced power protection with true online, double-conversion topology - Galaxy VS delivers reliable, clean power through a true online, double-conversion design. Incoming AC is rectified and then inverted to provide a regulated output regardless of input fluctuations. This results in minimal transfer times, suppression of voltage sags, harmonics, and transients, and consistently high quality power for sensitive servers, storage arrays, virtualization hosts, and network gear. The robust protection helps prevent data loss, application corruption, and unexpected shutdowns, making Galaxy VS a trusted backbone for business-critical workloads.
  • Flexible voltage configurations and scalable power range - The Galaxy VS platform accommodates multiple input/output voltages and a broad power range, including 20–100 kW at 480 V, 10–150 kW at 400 V, and 10–50 kW at 208 V. This flexibility is ideal for diverse IT environments, colocation facilities, and edge deployments where electrical distribution can vary significantly. Operators can tailor the UPS configuration to their specific topology, cabling, and redundancy goals, optimizing performance, footprint, and energy efficiency while maintaining reliable runtime for critical services.
  • Easy deployment, serviceability, and maintenance - The tower form factor, modular design, and hot-swappable components simplify both initial deployment and ongoing maintenance. Technicians can replace power modules, batteries, or control units without powering down the protected loads, reducing downtime and accelerating service windows. The compact footprint and modular layout minimize space requirements in data centers and edge sites, while the ability to perform field replacements and upgrades without extensive downtime helps keep operations running smoothly during a refresh or expansion.
  • Comprehensive monitoring, analytics, and seamless integration - Galaxy VS supports advanced monitoring and management options, including integration with Schneider Electric’s EcoStruxure IT and other monitoring platforms. Real-time health dashboards, alarms, load and battery metrics, and predictive maintenance insights help operators optimize uptime and capacity planning. Centralized visibility enables proactive maintenance planning, faster fault resolution, and better alignment with corporate security and governance requirements, ensuring dependable protection across distributed IT environments.

Technical Details of APC by Schneider Electric Galaxy VS 10kVA Tower UPS

  • Get this information from the "specifications" section of the product from https://ec.synnex.com/ using product "UPC" or "SKU" as reference

how to install APC by Schneider Electric Galaxy VS 10kVA Tower UPS

Installing the Galaxy VS Tower UPS involves thoughtful site preparation, careful physical installation, electrical connections, and proper commissioning. The steps below outline a high-level process to help you plan and execute safely. Always refer to the official installation manual for your exact model and follow local electrical codes and safety standards.

  • Plan the installation location with adequate clearance for service access, ventilation, and future expansion. Ensure the floor can support the combined weight of the UPS, battery cabinets, and any distribution equipment. Maintain environmental controls per manufacturer guidelines, including temperature, humidity, and airflow to optimize performance and lifespan.
  • Assemble the modular enclosure according to the recommended sequence. Install UPS modules, battery cabinets, and control hardware in the order specified by Schneider Electric, using proper cable routing, labeling, and grounding practices. Verify that input and output connections are correctly wired to the electrical distribution and that appropriate overcurrent protection is in place for all circuits.
  • Connect loads to the UPS output distribution and size fuses and breakers to match the UPS rating and downstream equipment requirements. Plan and implement proper cabling, strain relief, and heat management to minimize voltage drop and ensure reliable delivery to critical IT gear.
  • Power up the system and perform an initial configuration. Use the UPS interface or management software to set input/output voltages, battery charging parameters, and runtime priorities. Enable any redundancy options and configure alerts for battery health, temperature, and load thresholds.
  • Conduct commissioning and validation tests. Perform a simulated outage to verify transfer performance and runtime estimates, check battery health indicators, and verify alarms and notifications are correctly routed to the operations team. Document the final configuration, backups, and maintenance plans to support change-control and future audits.

Frequently asked questions

  • Q: What makes the APC Galaxy VS 10kVA Tower UPS suitable for edge deployments? A: Its modular, scalable design, compact tower footprint, and capacity to operate across multiple voltages make it ideal for edge environments where space is at a premium and reliability is essential for business-critical workloads.
  • Q: Can Galaxy VS scale from 20 kW to 100 kW and beyond? A: Yes. The Galaxy VS is built with a modular architecture that allows growth as demand increases, enabling you to add capacity and maintain protection without a full replacement.
  • Q: Does Galaxy VS support remote monitoring and integration? A: Galaxy VS integrates with Schneider Electric’s EcoStruxure IT and other monitoring tools to provide real-time health data, alerts, and predictive maintenance insights for centralized management.
  • Q: What kind of maintenance is required? A: Regular checks of battery health, firmware updates, and periodic self-tests are recommended. The modular design also facilitates quick component replacement and upgrades with minimal downtime.
  • Q: Is the Galaxy VS 10kVA Tower UPS compatible with 480 V, 400 V, and 208 V systems? A: The Galaxy VS platform supports multiple input voltages and can be configured to suit various electrical distributions commonly found in data centers and edge environments, providing flexible integration with existing infrastructure.