Description
APC Galaxy VS 80kVA Tower UPS
The APC by Schneider Electric Galaxy VS 80kVA Tower UPS delivers enterprise-class, modular power protection tailored for edge deployments, small to mid-size data centers, and other business-critical applications. This 3‑phase UPS is engineered to combine high efficiency with scalable redundancy, enabling you to protect sensitive IT loads while minimizing space, energy consumption, and total cost of ownership. With support for multiple input and output voltages (including 208 V, 400 V, and 480 V configurations), Galaxy VS provides a flexible, future-proof foundation for your evolving IT footprint. The 80kVA tier sits within a family designed for modular growth—you can start with a compact configuration and incrementally add power modules and battery banks as demand increases, all without interrupting critical workloads. Built for reliability, uptime is reinforced by hot-swappable power and battery modules, robust fault containment, and intelligent diagnostics that anticipate issues before they impact operations. In short, Galaxy VS is a scalable, easy-to-deploy, highly efficient solution that protects business continuity in today’s fast-moving IT environments.
- Modular, scalable architecture: Galaxy VS brings a modular design that supports incremental expansion to reach the 80 kVA capacity (roughly 64 kW) as your load grows. Hot-swappable power modules and battery strings enable quick maintenance and minimal downtime, so you can expand protection without replacing the entire system. This modularity also simplifies spare-part inventory and on-site service, reducing both capital and operating expenditures over the life of the UPS.
- High efficiency and impeccable power quality: Engineered for online, double-conversion operation, Galaxy VS maintains precise voltage regulation and low total harmonic distortion to safeguard sensitive IT equipment. The efficient power conversion reduces cooling and energy costs, while advanced waveform shaping and input power factor correction minimize disturbances from utility swings, ensuring clean, reliable power to servers, storage, and networking gear.
- Flexible deployment with a compact footprint: The tower form factor is designed for space-constrained data centers, edge facilities, and colocation environments where floor space and cooling capacity are at a premium. Its modular tower design supports streamlined rack or free-space installations, enabling engineers to optimize layout and airflow while still delivering scalable protection as workloads scale.
- Comprehensive protection and serviceability: Galaxy VS includes robust protection features such as short-circuit isolation, overload handling, surge suppression, and battery health monitoring. Predictive diagnostics and remote monitoring provide proactive insight, allowing IT teams to plan maintenance before failures occur. The hot-swappable components—both power modules and battery packs—maximize uptime and simplify servicing without disconnecting loads.
- Intelligent management and IT-ready connectivity: Designed for modern data-center operations, Galaxy VS is EcoStruxure IT Ready and integrates with APC monitoring solutions for centralized visibility. Real-time metrics on load, efficiency, battery health, and ambient conditions can be accessed locally or remotely via secure interfaces, enabling proactive capacity planning, rapid incident response, and streamlined change management.
Technical Details of APC Galaxy VS 80kVA Tower UPS
- Capacity: 80 kVA / ~64 kW (at 0.8 power factor) for typical 3-phase IT loads
- Topology: Online double-conversion (3-phase) UPS with modular, hot-swappable power modules
- Input voltage options: 208 VAC, 400 VAC, and 480 VAC three-phase configurations
- Output voltage options: 208 VAC, 400 VAC, and 480 VAC three-phase configurations to match IT equipment
- Efficiency: High online efficiency (design targets near 98% under optimal conditions) to reduce energy consumption and cooling load
- Form factor: Tower-mountable, modular enclosure designed for compact spaces and flexible installation
- Management interfaces: Local front-panel display with configurable settings; remote monitoring via SNMP, Modbus, USB, Ethernet; EcoStruxure IT Ready compatibility
- Battery system: Hot-swappable battery modules with battery health monitoring and string management for reliable runtime
- Protection features: Comprehensive protection including input power conditioning, back‑feed protection, surge suppression, and automatic internal safety checks
- Cooling and reliability: Integrated cooling with serviceable fans and redundant pathways to sustain performance in varying environments
- Warranty and serviceability: Designed for ongoing serviceability with widely available spare parts and nationwide support networks
How to install APC Galaxy VS 80kVA Tower UPS
Installing the Galaxy VS 80kVA Tower UPS should be performed by qualified electrical professionals in accordance with local electrical codes. The following steps outline a high-level, installer-focused process to help you plan and execute a successful deployment:
- Plan the site: Choose a location with a solid floor, adequate clearance for maintenance, and appropriate ventilation. Ensure room temperature and humidity are within the UPS’s specified operating range. Verify access to space for battery modules and service personnel, and confirm that the electrical distribution system can accommodate 208/400/480 V three-phase input with proper grounding.
- Unpack and inspect: Inspect all components for transit damage, verify that the module kit includes the expected power modules, batteries, cables, and accessories, and confirm compatibility with your IT load profile and UPS configuration.
- Mount and orient the unit: Position the tower UPS in the chosen location, ensuring clear clearance for intake and exhaust airflow. If using a floor-mounted stand or rack-adjacent setup, secure the unit according to manufacturer guidelines and local safety requirements.
- Connect inputs and outputs: Wire the three-phase input cables to the UPS input terminals according to the wiring diagram. Connect the UPS output to the IT equipment or distribution panel, ensuring correct phase sequencing and grounding. Install protective devices as required by code and ensure that all connections are tightened to specification.
- Install batteries and modules: Attach hot-swappable battery modules and power modules as specified, following the provided sequence to ensure correct electrical integrity and safe operation. Verify that battery strings are balanced and that battery monitoring is enabled in the management software.
- Configure management and monitoring: Connect the UPS to the network or local management interface. Configure input/output settings, runtime targets, protection thresholds, and remote monitoring credentials. Run initial health checks and firmware updates if available, and confirm that alerting and reporting are functioning properly.
- Commission and test: Perform a formal commissioning test, including a self-test, simulated outage, and transfer to inverter mode to validate runtime and load handling. Validate that all alarms, event logs, and notifications are functioning and that the IT loads remain protected during fault scenarios.
- Document and maintain: Record the installation details, configuration parameters, and maintenance schedule. Establish a preventive maintenance routine to monitor battery health, component wear, and firmware versions, ensuring long-term reliability and uptime.
Frequently asked questions
Q: What is the APC Galaxy VS 80kVA Tower UPS?
A: It is a modular, three-phase UPS designed for edge facilities, small to medium data centers, and other business-critical environments. With an 80 kVA rating and compatibility across 208 V, 400 V, and 480 V systems, it provides scalable protection, hot-swappable modules, and intelligent monitoring to maximize uptime and minimize operating costs.
Q: What workloads and environments is it best suited for?
A: Galaxy VS is ideal for edge deployments, compact data centers, network rooms, and distributed IT footprints where reliable power protection, space efficiency, and easy maintenance are essential. It supports growing IT ecosystems that require consistent power quality and predictable runtime.
Q: How does the management and monitoring work?
A: The UPS offers local front-panel controls and remote interfaces (SNMP, Modbus, USB, Ethernet). It is EcoStruxure IT Ready, enabling real-time visibility into load, efficiency, battery health, and environmental conditions. This facilitates proactive maintenance, capacity planning, and faster incident response across distributed sites.
Q: Can I upgrade capacity without replacing the entire unit?
A: Yes. The Galaxy VS architecture is designed for modular expansion, enabling you to add power modules and battery blocks to scale capacity while preserving existing IT loads, thereby reducing downtime and capital expenditure during growth.
Q: What kind of efficiency and power quality can I expect?
A: Galaxy VS emphasizes high online efficiency with precise voltage regulation and robust protection features. This combination minimizes energy waste and voltage disturbances, helping maintain data integrity and extending the life of your IT hardware.
Q: How do I ensure proper installation and ongoing maintenance?
A: Engage qualified electrical professionals for installation, follow the official commissioning procedures, and implement a preventive maintenance plan that includes battery health checks, firmware updates, and routine inspections of power modules, cooling, and connections. Regular monitoring through the built-in interfaces supports proactive upkeep.