APC by Schneider Electric Galaxy VS Bypass Cabinet


Price:
Sale price$16,446.18

Description

APC by Schneider Electric Galaxy VS Bypass Cabinet

Power reliability is non-negotiable in data centers, healthcare facilities, industrial environments, and commercial buildings. The APC by Schneider Electric Galaxy VS Bypass Cabinet is a purpose-built maintenance bypass solution that keeps critical loads powered while maintenance is performed on the main UPS. This maintenance bypass cabinet houses an integrated output transformer that takes the UPS’s high-voltage 480V output and steps it down to a safe 208V distribution level, enabling continuous operation of essential equipment without exposing personnel to live UPS internals. With its rugged enclosure and tightly controlled bypass path, technicians can isolate the UPS for service, re-route power, and test critical circuits with confidence. The Galaxy VS Bypass Cabinet is designed to integrate with 480V UPS configurations, delivering a seamless upgrade to your standby power strategy and a reliable path to minimize downtime during scheduled maintenance. In short, it provides a secure, code-compliant, and performance-minded solution for maintenance bypass that protects equipment, personnel, and uptime.

  • Maintenance bypass isolates the UPS during service operations – When a UPS unit requires servicing or replacement, the Galaxy VS Bypass Cabinet creates a dedicated bypass path that isolates the UPS from the critical load without interrupting power to connected equipment. The bypass mechanism is designed for operation by trained personnel, featuring clear interlocks and safe sequencing that ensures a reliable transition from normal UPS operation to bypass mode and back again. This capability reduces maintenance-induced downtime and accelerates service cycles, so your operation stays online while components are serviced and tested under controlled conditions.
  • Integrated output transformer for 208V distribution from 480V UPS – The cabinet houses an efficient output transformer that converts the UPS’s 480V output to a usable 208V distribution level. This eliminates the need for separate transformers or field wiring configurations, simplifying installation and reducing points of failure. The transformer design supports stable voltage conversion under varying load conditions, helping protect sensitive equipment downstream from voltage fluctuations during bypass operations.
  • Compatibility with 480V UPS systems – Engineered to work with common 480V UPS architectures, the Galaxy VS Bypass Cabinet provides a compatible, plug-in solution that integrates with existing electrical and control schemes. Its design aligns with the higher voltage standards used in enterprise and data center power environments, ensuring a seamless fit within your current infrastructure and helping you maximize the return on your UPS investment.
  • Rugged enclosure and safe interlock design – Built to endure challenging environments, the cabinet features a sturdy enclosure that protects critical components and maintains safe access for maintenance personnel. Interlocks and clearly defined bypass sequencing reduce the risk of accidental energization during installation or service, while ergonomic cable routing and labeling simplify routine checks and future upgrades.
  • Designed for reliability, safety, and uptime – The Galaxy VS Bypass Cabinet emphasizes protection for both people and equipment. By providing a controlled bypass path, it minimizes exposure to live UPS internals, maintains service continuity for essential loads, and supports compliance with power distribution standards. This solution is ideal for data centers, hospitals, manufacturing floors, and other settings where uninterrupted power during maintenance is critical.

Technical Details of APC by Schneider Electric Galaxy VS Bypass Cabinet

  • Purpose: Maintenance bypass cabinet with integrated output transformer
  • Input configuration: Designed for 480V UPS outputs
  • Output configuration: 208V distribution via transformer
  • Function: Isolates the UPS during maintenance while supplying the critical load
  • Compatibility: Suitable for 480V UPS systems in enterprise and data center environments
  • Construction: Durable, rugged cabinet designed for industrial settings
  • Safety features: Interlocks and controlled bypass sequencing to ensure safe operation

How to install APC by Schneider Electric Galaxy VS Bypass Cabinet

Preparation and planning are essential before installing the Galaxy VS Bypass Cabinet. Confirm that the UPS you are replacing or servicing is a 480V model and that the electrical room meets local codes and clearance requirements. Ensure that qualified personnel with appropriate PPE perform all work and that you have access to the UPS’s service bypass and isolation points. Review existing wiring diagrams and ensure the bypass cabinet will be positioned to minimize cable lengths and maintain proper clearances around the cabinet to support safe operation and future maintenance.

Step 1: Power-down and verify de-energization. Follow your site’s procedures to de-energize the UPS system and confirm zero-voltage conditions. Lockout/tagout protocols should be in place to prevent accidental re-energization during installation. Verify that the proposed cabinet location provides adequate ventilation and meets environmental requirements for heat dissipation and accessibility for routine maintenance.

Step 2: Mount and prepare the bypass cabinet. Secure the Galaxy VS Bypass Cabinet in the designated rack or stand-alone enclosure per manufacturer guidelines. Install any required seismic or vibration isolation hardware if your facility requires it. Label the cabinet clearly to indicate its role in the maintenance bypass pathway and ensure cable management provisions are ready for clean routing of input, output, and load cables.

Step 3: Connect input wiring. Connect the cabinet’s input terminals to the designated UPS output conductors, following color-coded wiring and the device’s connection diagrams. Double-check torque values for terminations and ensure insulation integrity to prevent arcing or loose connections. Use appropriate protective devices as specified by the site’s electrical design and ensure all connections are compliant with electrical codes.

Step 4: Connect output wiring and load. Route the transformer’s output to the downstream distribution path and the load panel that will receive the 208V supply during bypass operations. Verify that load ratings, conductor sizes, and protective devices align with the facility’s electrical design. Implement proper labeling to distinguish normal operation from bypass operation and ensure the operator can confidently switch between modes during maintenance scenarios.

Step 5: Verify interlocks and sequencing. With power re-enabled in a controlled test environment, validate that the interlocks engage correctly and that the bypass path operates as intended. Confirm that the UPS can be isolated, bypassed, and restored without disrupting critical loads. Conduct functional tests using a simulated or representative load to confirm voltage stability, fault protection, and protection of downstream equipment.

Step 6: Documentation and training. Update system drawings, wiring diagrams, and maintenance procedures to reflect the addition of the Galaxy VS Bypass Cabinet. Provide operators and maintenance personnel with training on bypass operations, safety interlocks, and emergency procedures. Establish routine inspection intervals to verify connectors, interlocks, and transformer integrity for long-term reliability.

Frequently asked questions

  • What is the primary function of the Galaxy VS Bypass Cabinet? It provides a controlled maintenance bypass path for UPS systems. This allows the UPS to be serviced or replaced without interrupting power to critical loads, while the integrated output transformer delivers 208V from the UPS’s 480V output.
  • Which UPS configurations are compatible with this bypass cabinet? The cabinet is designed to work with 480V UPS systems commonly used in data centers, hospitals, and industrial facilities. Compatibility depends on your UPS model and electrical design; consult your Schneider Electric representative or engineering team to confirm fit and wiring requirements.
  • How does the 480V to 208V transformation affect downstream equipment? The transformer steps down the voltage to a safe 208V distribution level suitable for downstream loads in the bypass path. It preserves power quality and helps maintain stable operation during maintenance, provided that the loads are rated for 208V operation.
  • Is it safe to perform maintenance while the bypass cabinet is in use? Yes, the cabinet is designed for safe operation during maintenance. It incorporates interlocks, sequencing logic, and clear operational procedures to minimize risk to personnel and equipment when performing service tasks on the UPS.
  • What kinds of facilities benefit most from this solution? Data centers, healthcare facilities, manufacturing floors, and enterprise buildings that rely on uninterrupted power during maintenance operations benefit significantly. The Galaxy VS Bypass Cabinet helps reduce downtime, maintain uptime commitments, and protect critical infrastructure during scheduled maintenance.