Apc By Schneider Electric Galaxy Vs Classic Battery Cabinet Ul Type 1


Price:
Sale price$18,936.47

Description

The APC Galaxy VS Classic Battery Cabinet from Schneider Electric is a purpose-built power storage solution designed to deliver reliable, scalable backup for critical IT environments. Engineered to meet UL Type 1 standards, this indoor cabinet houses Lead Acid VRLA (Valve-Regulated Lead Acid) batteries with a focus on dependable charging performance, safe servicing, and minimal maintenance. Ideal for data centers, server rooms, and edge computing installations, the Galaxy VS Classic combines rugged construction with thoughtful ergonomics to maximize uptime, reduce operational risk, and optimize total cost of ownership.

  • Reliable uptime with scalable design. Rugged construction provides a solid foundation for growing UPS configurations, enabling seamless integration with existing systems and future expansion without rework. This cabinet is purpose-built to support high availability environments where every second counts.
  • VRLA Lead Acid batteries for safe, leak-free operation. Valve-Regulated Lead Acid (VRLA) chemistry delivers reliable charging performance in confined IT spaces, reducing routine maintenance concerns and safeguarding data-center operations.
  • Maintenance-friendly access. The Galaxy VS Classic emphasizes easy access to battery terminals and terminations, making preventive maintenance straightforward and safe for technicians, with simplified servicing workflows and reduced downtime during battery checks or replacements.
  • UL Type 1 enclosure for compliant indoor deployments. The enclosure is UL Listed Type 1, ensuring safe installation in IT environments with robust protection, organized cabling, and airflow considerations that support efficient cooling and proper ventilation.
  • Optimized cost per watt-hour with dependable energy storage. By delivering dependable energy storage and a design geared toward long lifecycle performance, this cabinet helps minimize the total cost of ownership while maintaining high uptime in demanding IT settings.

Technical Details of APC by Schneider Electric Galaxy VS Classic Battery Cabinet

  • Battery chemistry: Lead Acid, Valve-Regulated Lead Acid (VRLA)
  • Enclosure: UL Type 1-rated Galaxy VS Classic Battery Cabinet for indoor IT environments
  • Maintenance access: Designed for easy reach to battery terminals and terminations
  • Certifications: UL Listed Type 1, ensuring compliance with essential safety standards
  • Form factor: Mounting compatibility with standard data center racks and support structures for flexible deployment

How to install APC Galaxy VS Classic Battery Cabinet

  • Validate compatibility with your UPS system and the surrounding rack or cabinet infrastructure, ensuring the Galaxy VS Classic will integrate smoothly with existing power and rack layouts.
  • Choose a location with adequate ventilation, stable floor support, and sufficient clearance for maintenance access and battery servicing to prevent heat buildup and ease serviceability.
  • Position the cabinet to allow clear cable routing and unobstructed access to terminals, while maintaining appropriate separation from heat sources and moisture-prone areas that could affect performance.
  • Gather the necessary tools and refer to the installation manual provided by Schneider Electric to ensure correct hardware and connection procedures are followed meticulously.
  • Begin with level placement and secure anchoring to the floor or rack system to prevent movement during operation or servicing, promoting safety and stability in busy data-center environments.
  • Connect the battery strings according to the wiring diagram, observing color-coded wires and proper termination practices to ensure safe, reliable electrical connections and predictable system behavior.
  • Perform a thorough safety check, verify all connections, and follow the commissioning steps outlined by Schneider Electric to bring the cabinet online with the UPS and cooling infrastructure.

Frequently asked questions

  • Q: What type of batteries does the Galaxy VS Classic use? A: It uses Lead Acid, Valve-Regulated Lead Acid (VRLA) batteries designed for reliable, sealed operation in data-center environments.
  • Q: What enclosure rating does this cabinet have? A: The Galaxy VS Classic features a UL Type 1-rated enclosure suitable for indoor IT deployments, with considerations for cable management and airflow.
  • Q: Is maintenance easy with this cabinet? A: Yes. The design emphasizes easy access to battery terminals and terminations, enabling quick, safe servicing and preventive maintenance to minimize downtime.
  • Q: Can this cabinet scale with my data center? A: The rugged construction is geared for scalable UPS configurations, allowing seamless integration with existing systems and future growth without rework, helping protect investments over time.
  • Q: How does this cabinet impact total cost of ownership? A: By delivering dependable energy storage, reducing maintenance complexity, and supporting high uptime, the Galaxy VS Classic helps optimize total cost of ownership across the cabinet’s lifecycle.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed