Description
Designed for demanding IT environments, the APC by Schneider Electric IT Power Distribution Module delivers reliable, scalable power distribution for business-critical applications. Built to meet the needs of data centers, server rooms, and enterprise racks, this 3-pole, 5-wire module supports up to 40A and uses IEC 309 connectors for global compatibility. Its generous 560 cm (5.6 m) length provides flexible routing, enabling you to place power where it’s needed most while minimizing cable clutter. Engineered to integrate seamlessly with APC Modular Power Distribution systems, this module simplifies global deployment and accelerates expansion as your IT footprint grows, delivering improved energy efficiency, reduced downtime, and streamlined maintenance for modern IT infrastructures.
- Ultra-high efficiency and scalable design: The Power Distribution Module is engineered to maximize energy efficiency across demanding workloads. By reducing thermal load and optimizing current distribution, it helps lower operating costs while supporting scalable expansion. Its modular architecture makes it easy to add circuits or reconfigure power paths as your IT environment evolves, so you can respond quickly to changing load requirements without overhauling your entire distribution network.
- Global deployment and standardized integration: With standardized interfaces and APC compatibility, this PDU integrates smoothly into diverse data centers and multi-site deployments. The module aligns with APC Modular Power Distribution systems, enabling consistent power distribution across locations and simplifying asset tracking, maintenance, and service support wherever your facilities reside. This standardization reduces deployment time and ensures reliable performance across server rooms, edge sites, and large-scale data centers.
- 3-pole, 5-wire configuration at 40A: This configuration delivers balanced, robust power delivery to critical IT equipment. The 3 hot conductors, along with neutral and protective earth, support dependable power to high-density servers, storage, and networking gear while maintaining proper fault protection and grounding. The 40A rating provides a safe margin for typical IT loads, helping prevent voltage dips and ensuring equipment operates within specification during peak demand.
- IEC 309 connectivity and long cable length: Employing IEC 309 (also known as CEE/IEC 60309) connectors, the module offers a rugged, standardized interface suitable for worldwide use. The substantial 560 cm (5.6 m) length affords flexible routing inside rack enclosures or between cabinets, reducing the need for intermediate distribution hardware and enabling cleaner, more organized installations.
- Durable, maintenance-friendly design: Built to withstand the rigors of data-center environments, this APC PDU emphasizes reliability and serviceability. Modular components simplify replacement and upgrades, helping to minimize downtime during maintenance windows. Clear labeling, accessible connection points, and compatible form factors ensure quick troubleshooting and speedy recovery from faults or component wear.
Technical Details of APC by Schneider Electric IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 560cm
- Configuration: 3-pole, 5-wire (three hot/phase conductors, neutral, and protective earth)
- Current rating: 40 A
- Connector type: IEC 309 (IEC 60309) compatible input/output connections
- Length: 560 cm (5.6 meters)
- Pole arrangement: 3P + N + PE
- Part format: Master power distribution module designed for APC Modular Power Distribution ecosystems
- Applications: IT power distribution for data centers, server rooms, and enterprise racks
How to install APC by Schneider Electric IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 560cm
- Plan and verify compatibility: Confirm that the APC Modular Power Distribution system in use supports 3P + N + PE configurations and that the IEC 309 connectors chosen match your facility’s electrical service characteristics. Ensure that the installation area is accessible, ventilated, and compliant with electrical safety standards.
- Power down and safety prep: Before installation, shut down nonessential equipment and de-energize the rack area as required. Use appropriate PPE and follow lockout/tagout procedures as dictated by site safety policies. Verify that the main power supply is isolated to prevent accidental energizing during installation.
- Mount and route the module: Install the Power Distribution Module within the APC modular framework or in a suitable rack/cabinet location. Route input and output cables in clean, organized pathways, avoiding pinch points and ensuring adequate clearance for airflow and maintenance access. Label cables clearly to facilitate future servicing.
- Connect input and outputs: Attach the IEC 309 input connector to the designated power source or distribution bus, and connect the corresponding output circuits to your IT devices or downstream PDUs as required. Verify secure connections and confirm that the neutral and earth conductors are properly bonded to the rack ground system.
- Verify functionality and safety testing: With power restored, perform a basic function check by powering on connected equipment and monitoring for proper voltage, current, and temperature readings. Ensure there are no abnormal noises, overheating, or fault indicators. Document test results and confirm that all circuits are protected and functioning within specification.
- Documentation and maintenance planning: Record model details, serial numbers, and installation dates for asset management. Schedule periodic inspections to verify connector integrity, cable wear, and overall system health. Keep spare components on hand to minimize downtime in the event of a fault.
Frequently asked questions
- What is the APC IT Power Distribution Module used for? It serves as a scalable, efficient power distribution solution for IT equipment within racks and data centers. It helps consolidate power paths, reduces wiring complexity, and integrates with APC Modular Power Distribution systems to support reliable operation of servers, storage, and networking gear.
- What does 3P + N + PE mean in this context? It indicates a three-pole (three hot/phase) configuration plus neutral and protective earth conductors, which provides balanced power delivery and proper grounding for critical IT loads in a three-phase electrical system.
- Is 40A sufficient for data center workloads? For many IT deployments, a 40A rating offers ample headroom for typical high-density racks and can be paired with appropriate breakers and monitoring to maintain voltage stability. Always assess your load profiles and consult a qualified electrician to ensure compliance with local electrical codes.
- How does IEC 309 connectivity benefit my installation? IEC 309 connectors deliver robust, standardized, weather-resistant power connections suitable for global deployment. They enhance safety and compatibility across different regions, reducing the need for adapters and improving reliability in harsh or demanding environments.
- Can I expand my APC distribution setup with this module? Yes. The module is designed to integrate with APC Modular Power Distribution systems, enabling scalable expansion as your IT footprint grows while maintaining consistent performance and manageability.
- What maintenance should I perform on this PDU? Regularly inspect cable routes and connectors, check for signs of wear or overheating, test protective earth continuity, and verify that monitoring and alerting systems are functioning. Keep spare parts and documented configurations to speed up recovery in case of a fault.