APC AP8830 Metered Rack PDU — L5-20P, 24× 5-20R, 120V, 20A


Price:
Sale price$861.65

Description

APC by Schneider Electric Metered Rack PDU

Meet the cornerstone of reliable, organized, and energy-aware power distribution in modern data centers and network closets: the APC by Schneider Electric Metered Rack PDU AP8830. This rugged, rack-mountable power distribution unit is designed to deliver stable, scalable power to dense equipment deployments while giving you critical visibility into energy consumption. With a 100–120 V input, a NEMA L5-20P inlet, and 24 NEMA 5-20R outlets, it provides a versatile, high-capacity solution for servers, switches, storage devices, routers, and other essential rack equipment. The AP8830 is finished in a sleek black enclosure that fits neatly into standard 19-inch racks, making it ideal for IT rooms, data centers, telecom closets, and workstation labs where space is at a premium and uptime is non-negotiable. By combining dependable power delivery with built-in metering, this PDU helps facilities managers optimize load, improve energy efficiency, and simplify capacity planning across IT infrastructure. Whether you’re provisioning new gear or consolidating existing assets, this module helps you keep the lights on while keeping operating costs in check.

  • Power and outlets: Provides 100–120 V input via a NEMA L5-20P inlet and 24 NEMA 5-20R outlets for flexible, high-density distribution to rack equipment. This configuration supports a wide range of devices and minimizes the need for excessive daisy-chaining or power strips in the rack.
  • Metered energy management: Built-in metering delivers real-time monitoring of power usage, helping you track total load and energy consumption. With visibility into current draw and overall usage, you can make informed capacity decisions, reduce wasted energy, and plan for future growth without guesswork.
  • Safety and compliance: Engineered to meet stringent regulatory standards, including FCC Part 15 Class A, ICES-003, and UL 60950-1-2, the AP8830 emphasizes electrical safety, EMI/EMC compliance, and compliant performance in professional environments where reliability matters most.
  • Rugged rack-mount design: The black enclosure is purpose-built to withstand demanding IT environments and fits seamlessly into standard 19-inch rack systems. Its compact footprint supports efficient cabling and enhanced airflow around servers and networking gear while maintaining a clean, professional rack appearance.
  • Versatile deployment and management: Ideal for data centers, server rooms, and network closets where centralized power distribution and load awareness are critical. The AP8830 supports scalable deployments and simplifies cable management, device placement, and ongoing maintenance, enabling proactive power planning as your infrastructure evolves.

Technical Details of APC by Schneider Electric Metered Rack PDU

  • Model: AP8830
  • Type: Metered Rack PDU
  • Input: 100–120 V, NEMA L5-20P
  • Output: 24 x NEMA 5-20R
  • Power rating: 1920 VA, 20 A
  • Color: Black
  • Mounting: Rack-mountable (standard 19-inch rack)
  • Certifications: FCC Part 15 Class A, ICES-003, UL 60950-1-2
  • Application: Suitable for data centers, server rooms, and network closets needing centralized power distribution with energy metering

How to install APC Metered Rack PDU

  • Choose a suitable location in a standard 19-inch rack with adequate ventilation to prevent overheating and ensure easy cable access.
  • Secure the AP8830 to the rack using the included mounting hardware, aligning it with available mounting rails and ensuring the unit is level for proper plug alignment and cable routing.
  • Connect the power cord from the NEMA L5-20P inlet to a compliant AC power source that can supply up to 20 A at 100–120 V. Verify that the circuit can handle the anticipated load of connected devices.
  • Physically connect all rack devices to the 24 x NEMA 5-20R outlets. Label each outlet as needed to facilitate clean management of your rack assets and to support ongoing troubleshooting and capacity planning.
  • Power on the PDU and verify that the energy metering readings are active. Check that all connected equipment powers up correctly and that the load remains within safe limits to avoid tripping circuit protection.
  • Organize cables for improved airflow and ease of future maintenance. If your setup includes additional PDUs or power management equipment, plan a scalable configuration to accommodate growth.

Frequently asked questions

  • What does the Metered Rack PDU AP8830 provide? It delivers centralized power distribution for rack equipment with built-in metering, allowing you to monitor real-time energy usage and manage load more effectively in a 100–120 V, 20 A system with 24 NEMA 5-20R outlets.
  • What outlets and input connectors are included? The unit uses a NEMA L5-20P input connector and offers 24 NEMA 5-20R outlets for flexible appliance and server connections.
  • What are the regulatory certifications? The AP8830 carries FCC Part 15 Class A, ICES-003, and UL 60950-1-2 certifications, supporting safe, compliant operation in professional settings.
  • Where is this PDU best used? It’s well-suited for data centers, server rooms, and network closets where reliable power distribution and energy visibility are critical for uptime, capacity planning, and energy efficiency.
  • Is this PDU compatible with standard rack installations? Yes. The AP8830 is designed to fit standard 19-inch racks and is compatible with typical data-center rack layouts, supporting clean cable management and straightforward integration with existing infrastructure.