Description
Discover a smarter way to organize power and data cabling inside your APC rack enclosure with the Mounting Adapter Kit for Rack in a sleek black finish. This adapter kit is engineered to simplify installation, improve cable management, and keep power and data paths clearly separated for cleaner airflow, easier maintenance, and enhanced system reliability. Designed for seamless integration with APC by Schneider Electric rack systems, it delivers a tool-less, secure solution that helps you maximize enclosure efficiency and minimize downtime.
- Tool-less, fast installation: The Mounting Adapter Kit is built for quick, tool-free deployment. Set up happens in minutes, reducing service time and labor costs while letting you reconfigure or scale your rack setup with minimal interruption.
- Overhead cable troughs and partitions: This kit enables overhead cable troughs and partitions to install directly on the roof of the enclosure. By eliminating the need for ceiling-mounted or underfloor-mounted trays, it simplifies cabling layouts and supports organized, clean routing of both power and data cables.
- Separate power and data pathways: Designed to maintain clear separation between power and data cables, the system helps minimize interference, improve signal integrity, and optimize cooling efficiency within the rack enclosure.
- Durable black finish for professional environments: The mounting adapters and related components feature a rugged, powder-coated black finish that blends with common data-center aesthetics and provides increased durability in hot or humid environments.
- Scalable, modular cable management: Built to accommodate growing systems, this kit supports scalable cable management solutions and integrates smoothly with existing APC accessories to keep cables tidy, accessible, and easy to service.
Techncial Details of APC by Schneider Electric Mounting Adapter Kit for Rack
- Product Type: Mounting Adapter Kit for Rack
- Color: Black
- Finish: Powder-coated steel finish for durability and corrosion resistance
- Material: Steel construction designed for rigidity and long-term use in data-center environments
- Compatibility: Specifically designed to work with APC by Schneider Electric rack systems, enabling installation of overhead cable troughs and partitions on the enclosure roof
- Installation: Tool-less installation to simplify deployment and reconfiguration within APC racks
- Applications: Cable management for power and data cables, with emphasis on maintaining separation to support performance and airflow
- Contents: Mounting adapters and associated components required for installation (contents may vary by SKU)
how to install APC by Schneider Electric Mounting Adapter Kit for Rack
Follow these general steps to install the Mounting Adapter Kit for Rack within an APC enclosure. This guide emphasizes safe handling, proper alignment, and ensuring clean cable routing for optimal performance.
1) Prepare the enclosure: Power down the rack system according to your facility’s safety procedures. Confirm you have all components included in the kit and verify compatibility with your APC rack model.
2) Align the mounting adapters: Position the mounting adapters on the roof interior of the enclosure where overhead cable troughs will be attached. Ensure alignment with existing rails or mounting points to prevent binding or misalignment.
3) Secure the adapters: Engage the tool-less securing mechanism provided with the kit. If screws or additional fasteners are included for your SKU, use them to lock the adapters firmly in place. Check for even seating and confirm there is no wobble.
4) Install cable troughs and partitions: Attach overhead cable troughs and partitions to the mounted adapters. Route power and data cables through the appropriate troughs, maintaining separation between the two pathways to minimize interference and maximize airflow.
5) Route and organize cables: Use cable ties or Velcro straps (as recommended by APC) to secure cables within the troughs. Label cables where helpful to simplify future maintenance and upgrades. Confirm that cables are not overly tight and that there is adequate slack for serviceability.
6) Final checks and power restoration: Inspect the completed installation for any loose components or obstructions. Restore power and verify that all connections are secure. Observe the system for proper operation and ensure airflow is unobstructed by cable placement.
By following these steps, you’ll achieve a neat, efficient cabling layout that supports both performance and ease of maintenance. The tool-less nature of the kit minimizes downtime during installation or reconfiguration, making it an ideal choice for dynamic data-center environments that frequently adapt to new equipment, additional servers, or upgraded networking gear.
Frequently asked questions
- Q: What is the primary purpose of the mounting adapter kit?
- A: It enables tool-less installation of overhead cable troughs and partitions on APC rack roofs, allowing clean separation and management of power and data cables within the enclosure.
- Q: Is this kit compatible with all APC rack models?
- A: The kit is designed for APC by Schneider Electric rack systems. Confirm compatibility with your specific enclosure model and SKU before purchase.
- Q: Does the kit include overhead cable troughs?
- A: The Mounting Adapter Kit provides the mounting hardware to install troughs and partitions. Contents may vary by SKU, so check the product package to confirm included components.
- Q: How does this kit improve cable management?
- A: By enabling overhead routing of power and data cables with dedicated partitions, reducing clutter, improving airflow, and minimizing electromagnetic interference between cables.
- Q: Can I upgrade my existing APC enclosure with this kit?
- A: Yes, if your enclosure is compatible with APC mounting adapters and overhead troughs. The kit is designed to integrate into APC rack systems to enhance cable management and space utilization.
Customer reviews