Description
The APC NetShelter 42-Outlets PDU is a robust, advanced metered power distribution unit designed to power dense IT racks with precision and visibility. Built for data centers, edge deployments, and demanding labs, this PDU streamlines energy management, reduces waste, and helps safeguard uptime by providing granular, real-time insight into power usage at the rack level. With 42 outlets, versatile 4-in-1 connectivity options, and a rugged NetShelter form factor, it adapts to a wide range of server, storage, and networking configurations while keeping cabling tidy and manageable. The integrated LCD display, secure remote monitoring capabilities, and proactive overload protection empower IT teams to forecast capacity, prevent overloads, and maintain SLA performance even in fast-moving environments. Whether you’re deploying blade servers, high-density switches, KVM consoles, or storage arrays, the NetShelter PDU delivers reliable power delivery, smarter energy management, and resilient uptime for modern data infrastructures.
- Real-time metering at the rack level with voltage, current, and energy data, accessible via secure web interface or SNMP; proactive overload detection helps prevent outages before they impact uptime.
- 42 outlets configured for IT equipment with flexible connectivity thanks to 4-in-1 combination outlets, supporting mixed devices and cleaner cabling for easier cable management inside the rack.
- Rugged, 19-inch rack-mountable enclosure designed for data centers, edge deployments, and remote sites, delivering durable performance with minimal maintenance and straightforward installation.
- Comprehensive management and compatibility: secure web interface, SNMP, and compatibility with APC Network Management Card (NMC) or EcoStruxure IT for centralized visibility, proactive diagnostics, and streamlined asset management across multi-rack environments.
- Global-ready power input and safe operation: supports 100–250 VAC, 50/60 Hz input with up to 50 A service, enabling deployment in diverse utility environments and multi-site installations while supporting 208 V, 3-phase configurations in compatible wiring schemes.
Technical Details of APC by Schneider Electric NetShelter 42-Outlets PDU
- Power input: 100–250 VAC, 50/60 Hz (global IT deployments) with up to 50 A service rating for demanding workloads.
- Outlets: 42 total outlets configured for IT equipment; a mix of IEC outlet types to accommodate servers, storage, and networking gear (configuration may vary by SKU).
- Metering: PDU-level power monitoring with real-time data on voltage, current, and energy consumption to support capacity planning, energy optimization, and SLA adherence.
- Display: Local LCD display for quick, at-a-glance status checks; provides immediate visibility even when network access is limited.
- Management and connectivity: secure web interface, SNMP compatibility, and compatibility with APC Network Management Card (NMC) or EcoStruxure IT for centralized visibility and remote diagnostics.
- Physical design: rugged, rack-mountable enclosure designed for deployment in data centers, edge environments, and remote sites; standard 19-inch mounting with included rails and installation hardware.
- Outlet configuration: 4-in-1 combination outlets that adapt to mixed IT loads, enabling flexible connectivity and cleaner cabling within the rack.
- Safety and reliability: engineered to deliver consistent performance under demanding conditions with low maintenance requirements to sustain uptime.
How to install APC NetShelter 42-Outlets PDU
- Prepare the rack: Verify that your 19-inch rack is compatible with the NetShelter PDU, clear space for cable management, and ensure adequate clearance for proper airflow around the equipment.
- Mount the PDU: Attach the PDU to the rack rails using the provided mounting brackets and screws. Ensure a secure, level installation to prevent vibration and wear over time.
- Route power and data connections: Connect the PDU’s input power cord to a suitable power source that matches the specified input (100–250 VAC, 50/60 Hz). Plan cable routing to minimize clutter and maximize airflow within the rack.
- Connect IT equipment: Distribute servers, storage, switches, and KVM consoles across the 42 outlets, taking advantage of the 4-in-1 outlets to optimize footprint and cabling efficiency.
- Configure monitoring and alerts: Access the PDU via the secure web interface or use SNMP to enable remote monitoring. If using NMC or EcoStruxure IT, link the PDU to your centralized management system and set threshold alerts for voltage, current, and energy usage.
- Validate operation: Power on the rack, verify LCD readouts, confirm that outlet power distribution matches asset deployment, and test alarms to ensure proactive notification workflows are functional.
- Document and optimize: Tag critical loads, establish future capacity plans, and build dashboards that track energy usage by rack to inform procurement, cooling strategies, and SLA compliance across the data center or edge environment.
Frequently asked questions
- What devices can be powered by the 42-outlet NetShelter PDU? — It is designed to support a wide range of rack-mounted IT gear, including servers, storage arrays, switches, blade enclosures, and KVM consoles. Outlet types and exact configurations vary by SKU, so check your regional specification to match devices to outlets.
- Does the PDU provide real-time power metering? — Yes. The PDU offers PDU-level metering that reports voltage, current, and energy consumption in real time, enabling precise capacity planning and energy optimization at the rack level.
- Can I monitor this PDU remotely? — Absolutely. The unit supports a secure web interface and SNMP for remote monitoring, and it is compatible with APC NMC or EcoStruxure IT for centralized visibility, alerting, and asset management across multiple racks.
- Is the PDU compatible with 208V 3-phase data centers? — The NetShelter PDU is designed for global deployments; 208V three-phase configurations are supported in compatible wiring schemes and SKUs. Review the SKU-specific outlet and electrical configuration to ensure full compatibility.
- How do I install and configure the PDU? — Install the PDU in a standard 19-inch rack, connect to a suitable power feed, mount and route cables for clean cable management, then configure monitoring via the web interface or NMC/EcoStruxure IT and set up alert thresholds and dashboards for ongoing visibility.