APC by Schneider Electric NetShelter Rack PDU Advanced Three Temperature and Humidity Sensor
The APC NetShelter Rack PDU Advanced with Three Temperature and Humidity Sensors is the pinnacle of intelligent rack power distribution. Built for data centers that demand reliability, efficiency, and precise environmental awareness, this PDU delivers best-in-class power management with groundbreaking monitoring capabilities. It’s engineered to support the densest configurations, streamline deployment, and give you granular insight into both power and environmental conditions at the rack level. Whether you operate a high-density data center, a server room, or a field-deployed edge environment, this PDU helps you optimize uptime, reduce cooling costs, and extend the life of your IT equipment.
With up to 50% more power capacity than conventional PDUs and twice as many outlets, the NetShelter Advanced PDU is designed to power modern racks with confidence. The 4-in-1 combination outlet design simplifies cabling, accelerates deployment, and reduces clutter, enabling cleaner rack layouts and better airflow. The result is improved airflow, more efficient cooling, and a leaner, more manageable data center footprint. This PDU isn’t just about power distribution—it’s about intelligent infrastructure that empowers proactive management, precise environmental control, and scalable growth as your IT needs evolve.
Central to its value proposition are the three integrated temperature and humidity sensors. These sensors monitor critical points around the rack to provide an accurate picture of the cooling environment and humidity levels. By delivering real-time data on inlet temperature, ambient room conditions, and localized humidity, the NetShelter PDU Advanced enables rapid detection of hotspots and quicker response to changing conditions. The data can be used to tune cooling strategies, trigger alarms before problems escalate, and support capacity planning with confidence.
The PDU’s powerful monitoring capabilities extend beyond temperature and humidity. It supports remote management and alerting through compatible software, SNMP, and APC’s management ecosystem, giving you visibility from anywhere. You can track power usage, monitor outlet load, set thresholds for alerts, and integrate with data center infrastructure management (DCIM) tools. This level of insight helps you optimize energy usage, reduce operational costs, and maintain service-level objectives across your IT environment.
Designed with deployment practicality in mind, the NetShelter Rack PDU Advanced is compatible with APC NetShelter cabinets and other common rack installations. Its modular design makes it easy to upgrade or expand as you scale, and the robust construction is built to withstand the rigors of data center environments. The combination of enhanced power capacity, flexible outlet configurations, and comprehensive environmental sensing makes this PDU a versatile foundation for reliable power distribution and proactive environmental management in today’s data centers.
- Three temperature and humidity sensors deliver precise environmental monitoring at the rack, enabling proactive cooling management and hotspot detection.
- Up to 50% more power capacity than standard PDUs plus twice as many outlets to support higher-density equipment and future growth.
- 4-in-1 combination outlet design for fast, flexible deployment, streamlined cabling, and improved airflow within the rack.
- Intelligent remote management and alerting through compatible software, SNMP, and APC’s network interfaces for centralized visibility.
- Rugged, rack-ready design optimized for data centers, server rooms, and edge deployments requiring reliable power distribution and environmental sensing.
Technical Details of APC by Schneider Electric NetShelter Rack PDU Advanced Three Temperature and Humidity Sensor
- Get this information from the "specifications" section of the product from https://ec.synnex.com/ using product "UPC" or "SKU" as reference
How to install APC by Schneider Electric NetShelter Rack PDU Advanced Three Temperature and Humidity Sensor
- Power down and unplug equipment as required before installation to ensure safety and prevent electrical shocks.
- Mount the PDU securely into a compatible APC NetShelter rack, following the manufacturer’s rack-mount guidelines for clean alignment and stable support.
- Connect the PDU to your building power according to local electrical codes and the PDU’s voltage and current ratings. Use appropriate circuit breakers and wire gauges as specified by Schneider Electric.
- Configure the 4-in-1 outlets and assign device loads to outlets according to your rack layout. Integrate the three temperature and humidity sensors into the monitoring system for real-time environmental data.
- Enable remote monitoring and alerting through your chosen management software or DCIM tools. Set alert thresholds for temperature, humidity, and power load to receive notifications before conditions impact performance.
Frequently asked questions
- Q: What does the three temperature and humidity sensor feature monitor? A: It monitors critical points around the rack to detect temperature fluctuations and humidity levels, enabling proactive cooling and environmental control.
- Q: Can I monitor power usage remotely? A: Yes. The NetShelter Rack PDU Advanced provides remote power and environmental monitoring through compatible management software and SNMP.
- Q: How does the 4-in-1 outlet design benefit deployment? A: It simplifies cabling, reduces clutter, and improves airflow by consolidating outlets into versatile configurations that adapt to various equipment layouts.
- Q: Is this PDU compatible with APC NetShelter cabinets? A: Yes. It is designed for seamless integration with APC NetShelter racks and other compatible rack enclosures.
- Q: What environments is this PDU best suited for? A: High-density data centers, server rooms, and edge deployments where reliable power distribution and accurate environmental monitoring are critical.