Description
The APC by Schneider Electric NetShelter SX 48U Duct Kit for Cisco Nexus 7018 is an expertly engineered air distribution solution designed to maximize cooling efficiency in power-dense data center racks. Tailored for environments where high-density equipment and low static pressure can challenge traditional cooling, this duct kit helps direct conditioned air precisely where it’s needed. By integrating seamlessly with APC NetShelter SX enclosures and Cisco Nexus 7018 network switches, it delivers improved airflow management, reduced hotspots, and enhanced overall system reliability. If you’re looking to protect critical networking gear while maintaining optimal temperatures, this duct kit is a smart investment for scalable, energy-efficient data center operations.
- Enhanced airflow management for power-dense racks: The duct design concentrates and channels cool air across dense Cisco Nexus 7018 deployments, helping to lower inlet temperatures and minimize hot spots in the rack enclosure.
- Compatibility with NetShelter SX enclosures and Cisco Nexus 7018: Engineered to integrate with APC NetShelter SX systems and Cisco Nexus 7018 switches, ensuring a cohesive, plug-and-play airflow solution that preserves existing rack configurations.
- Low-pressure, high-efficiency cooling: By optimizing air distribution, the kit supports lower fan speeds and reduced energy consumption while maintaining consistent cooling performance across all ports and blades.
- Durable construction for data center environments: Built from rugged steel with a durable powder-coated finish, the duct kit withstands the rigors of daily data center operation and frequent access for maintenance.
- Modular, scalable design for future growth: The kit’s modular components enable flexible configurations and straightforward expansion as your network grows and cooling requirements evolve.
Technical Details of APC NetShelter SX 48U Duct Kit for Cisco Nexus 7018
- Compatibility: Designed for APC NetShelter SX enclosures and Cisco Nexus 7018 switches; works with standard 19-inch rack mounting rails.
- Construction: Heavy-gauge steel with a durable powder-coated finish built to withstand demanding data center environments and frequent service access.
- Air distribution features: Integrated duct plenums and configurable airflow paths to optimize cool air delivery to high-density equipment and adjacent devices.
- Finish: Black powder-coated surface for a consistent aesthetic with APC NetShelter SX installations and compatible network gear.
- Weight and dimensions: Weight and dimensions vary by configuration and rack size; exact figures are UPC/SKU-dependent and should be verified against product specifications for your setup.
- Mounting and compatibility notes: Includes standard mounting hardware compatible with 19-inch rack systems; designed to fit the NetShelter SX line and support Cisco Nexus 7018 deployments.
How to Install APC NetShelter SX 48U Duct Kit for Cisco Nexus 7018
Installing the NetShelter SX 48U Duct Kit is a straightforward process designed to minimize downtime and help you achieve reliable airflow in a compact, power-dense rack environment. Follow these steps to ensure a secure, effective setup that delivers the intended cooling benefits for your Cisco Nexus 7018 and adjacent gear:
- Preparation: Confirm compatibility with your NetShelter SX enclosure and Cisco Nexus 7018 model. Gather the included mounting hardware, tools, and any installers’ documentation. Power down non-essential equipment if required and follow your data center’s safety procedures.
- Access and assessment: Open the enclosure doors and assess the current airflow layout. Identify the locations where the duct components will be installed to maximize intake air delivery to hot zones around the Nexus 7018 blades and adjacent devices.
- Mounting the duct kit: Attach the duct plenums to the enclosure’s interior framework using the provided hardware. Ensure that all fasteners are snug but not over-tightened, and align the ducts with the intended airflow paths for optimal cold air delivery.
- Sealing and cable management: Route cables neatly to avoid obstructing the airflow paths. Use any included gaskets or seals to minimize bypass air and maintain consistent pressure across the rack interior.
- System configuration and testing: Restore power and gently power up the Cisco Nexus 7018 and related network gear. Monitor intake temperatures at critical points to confirm that the ducts are delivering the intended cooling and that no new hotspots have emerged.
- Fine-tuning and maintenance: If temperatures indicate imbalances, adjust duct positions or add/remove plenums as needed. Periodically inspect the duct kit for dust buildup, loose fasteners, or wear, and perform routine cleaning to preserve airflow efficiency.
Frequently Asked Questions
- What is the primary benefit of the NetShelter SX 48U Duct Kit for Cisco Nexus 7018? It optimizes airflow within power-dense racks, reducing hotspots and enabling more efficient cooling for high-density equipment, including Cisco Nexus 7018 switches, within NetShelter SX enclosures.
- Is this duct kit compatible with other Cisco devices or only the Nexus 7018? The kit is designed for use with Cisco Nexus 7018 deployments in APC NetShelter SX enclosures; it may support other compatible devices when used in conjunction with the same enclosure and airflow path design, but consult product documentation for confirmation.
- Do I need special tools to install the duct kit? Most installations rely on standard tools commonly used for rack hardware, such as hex wrenches or screwdrivers, along with the included mounting hardware. Always follow safety guidelines and your facility’s procedures.
- Can the duct kit be reconfigured if my rack layout changes? Yes. The design is modular and scalable to accommodate evolving cooling needs and additional equipment; you can adjust plenums and pathways to suit new configurations.
- How does this kit affect energy efficiency? By delivering cooler air more directly to high-heat zones, the kit supports optimized airflow, which can reduce fan speeds and lower overall energy consumption while maintaining stable operating temperatures.
- Where can I find exact specifications for my UPC or SKU? Exact specifications such as weight and dimensions are SKU- and UPC-dependent. Check the product’s documentation or the official vendor catalog for precise figures associated with your specific UPC/SKU.