APC NetShelter SX AR3307SP2X561 Rack Cabinet – 48U Black Server Enclosure

Designed by APC, a trusted name in data center reliability, the NetShelter SX AR3307SP2X561 Rack Cabinet is a premium 48U enclosure built to protect, organize, and optimize your server, networking, and power distribution hardware. This black rack cabinet blends sturdy construction with practical access and cooling features, helping IT teams deploy robust infrastructure with ease. Ideal for data centers, server rooms, and network closets, it provides secure storage for critical equipment while promoting clean cabling, efficient airflow, and simple maintenance. With universal 19-inch mounting compatibility and modular accessories, the AR3307SP2X561 adapts to growing IT environments while maintaining a sleek, professional appearance.

Key features and benefits — the AR3307SP2X561 is built to streamline deployment, reduce downtime, and extend asset life. A rigid, powder-coated steel frame delivers durability and rigidity to withstand the rigors of daily rack use. Lockable doors and solid construction deter tampering and protect valuable hardware. The enclosure is designed for versatility, enabling quick access to equipment for maintenance and upgrades and enabling clean, organized cable routing for improved airflow and easier troubleshooting. Whether you’re mounting servers, PDUs, network switches, or storage devices, this rack cabinet provides a stable foundation that helps optimize performance and reliability.

  • Robust 48U rack height: The spacious 48U footprint accommodates a broad range of IT gear—from blade servers and rack-mount servers to PDUs and patch panels. This generous height minimizes the need for multiple smaller enclosures and simplifies future expansion while keeping your equipment securely housed in a single, organized space.
  • Secure, professional presentation: Finished in a sleek black powder coat, the NetShelter SX cabinet presents a tidy, professional appearance in data centers and server rooms. Rugged construction and lockable front and rear doors help protect assets and keep maintenance performed on your terms, without compromising security or access for authorized personnel.
  • Universal 19-inch compatibility: Built to accommodate standard 19-inch equipment, this cabinet supports a wide range of rack-mount servers, switches, storage arrays, and PDU configurations. The design simplifies inventory management and reduces compatibility concerns when you mix gear from different vendors.
  • Optimized airflow and serviceability: Vented doors and side panels promote airflow while providing easy access for cable routing and component installation. Cable management features and modular accessories help organize power and data paths, minimizing cooling hotspots and facilitating efficient maintenance and upgrades.
  • Flexible, scalable, and easy to install: The AR3307SP2X561 is engineered for flexible deployment in various environments—from compact network closets to larger data centers. Its modular approach supports future expansions and upgrades with minimal downtime and disruption to ongoing operations.

Technical Details of APC NetShelter SX AR3307SP2X561

  • SKU: AR3307SP2X561
  • Rack height: 48U
  • Color: Black
  • Compatibility: Standard 19-inch rack-mounted equipment
  • Construction: Steel with durable powder-coated finish
  • Intended use: Server, PDU mounting and general IT rack housing

The above technical details reflect common specifications associated with APC NetShelter SX AR3307SP2X561-series enclosures. For a complete, site-specific spec sheet, refer to the official product listing and vendor documentation. The information is presented here to help you quickly assess fit for your environment while you review the full specifications from the supplier’s portal.

How to install APC NetShelter SX AR3307SP2X561

Installing the APC NetShelter SX AR3307SP2X561 is a straightforward process designed for efficiency and reliability. Follow these general steps to set up your 48U rack cabinet for immediate use, keeping in mind site-specific requirements and the equipment you plan to deploy.

1) Plan and prepare the space: Ensure the installation area is level, has adequate ventilation, and can support the cabinet’s weight when fully loaded. Verify floor load capacity and confirm access for equipment, tools, and cable management components. Prepare any accessories you plan to use, such as mounting rails, cable managers, PDUs, and door or panel kits.

2) Unbox and inspect: Prior to assembly, inspect the cabinet for any shipping damage. Confirm that door locks, hinges, and mounting rails are present and undamaged. Read any included installation guides carefully to understand the order of assembly and any site-specific considerations.

3) Assemble the cabinet frame: Assemble the rack cabinet frame per the manufacturer’s instructions. This typically involves securing the base, casters or feet (if included), and the frame with the appropriate fasteners. Verify that all components are aligned and securely tightened to maintain rigidity during equipment installation.

4) Install mounting rails: Attach adjustable 19-inch mounting rails to the front and/or rear of the cabinet as specified by the design. Rails should be level and aligned to ensure proper mounting of server and rack-mount equipment. When installing rails, consider the depth of your devices and plan for future growth to minimize rework.

5) Mount equipment and manage cables: Begin with critical devices such as PDUs and primary servers, routing cables neatly with the cabinet’s cable management features. Use cable ties and Velcro straps to organize power, data, and cooling lines, minimizing cross-talk and airflow obstruction. Install blanking panels if needed to improve cooling efficiency and airflow uniformity within the cabinet.

6) Install doors and security features: Attach front and rear doors and engage any locking mechanisms to secure your equipment. Verify that doors operate smoothly and that locks function as intended. For environments requiring extra protection, consider adding side panels or additional lockable components per your security policy.

7) Verify airflow and test readiness: With equipment installed, confirm that airflow paths are clear and that ventilation openings remain unobstructed. Power up devices in a controlled sequence, monitoring for any abnormal temperatures or airflow restrictions. Conduct a basic functional test to ensure all devices boot correctly and are reachable over the network.

8) Documentation and maintenance planning: Create a clear layout map of installed devices, including port assignments and cable routes. Maintain an up-to-date inventory for future upgrades and service calls. Establish a routine maintenance schedule to inspect locks, seals, and airflow pathways to preserve performance over time.

Frequently asked questions

  • What is the APC NetShelter SX AR3307SP2X561 used for? It is a dedicated rack cabinet designed to securely house 19-inch equipment such as servers, PDUs, switches, and storage devices. Its 48U height provides ample space for growth while maintaining a compact footprint suitable for data centers and server rooms.
  • Is this cabinet compatible with standard 19-inch racks? Yes. The NetShelter SX AR3307SP2X561 is built to support standard 19-inch equipment, enabling you to mount a wide range of vendors’ gear in a single enclosure.
  • Does it have lockable doors? Yes. The cabinet includes lockable front (and typically rear) doors to help secure equipment and deter unauthorized access, which is important in shared data center environments.
  • Can I customize the interior layout with adjustable rails and cable management? Absolutely. The AR3307SP2X561 is designed with adjustable mounting rails and integrated cable management features to support flexible configurations and tidy cabling for improved cooling and maintenance.
  • Where can I find the complete specifications and installation guidelines? You should refer to the vendor’s official product page or data sheet. The summary here highlights key capabilities, but the full spec sheet will provide exact dimensions, weight capacity, and additional accessories recommended for your configuration.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed