Description
Designed for speed, reliability, and safety, the APC by Schneider Electric Output Hardwire Kit is the essential accessory that transforms how you connect your uninterruptible power supply (UPS) to your building’s electrical system. Engineered by Schneider Electric, a global leader in power protection and critical infrastructure, this hardwire kit offers a robust, code-compliant pathway for distributing backup power where you need it most. Whether you’re outfitting a small office, a data center rack, or a telecom room, this kit enables a clean, professional, and scalable hardwire connection that minimizes downtime and maximizes uptime. Optimized for compatibility with APC UPS systems that support hardwired output, the kit emphasizes ease of installation, durable construction, and lasting performance in challenging environments such as data centers, server rooms, or industrial settings.
- Seamless UPS-to-distribution integration: The Output Hardwire Kit provides a direct, professional-grade connection from your APC UPS output to your electrical distribution panel, enabling reliable power delivery to critical loads during utility outages.
- Durable, purpose-built design: Built with rugged components and secure terminal blocks, the kit stands up to the demands of on-site installations, including vibration, temperature variations, and continuous operation in data centers and network closets.
- Efficient, space-saving installation: The compact form factor and included mounting hardware simplify installation in crowded rack enclosures, wall-mounted cabinets, or utility spaces, reducing footprint while maintaining clear, accessible wiring paths.
- Safety-first construction and compliance: The kit emphasizes safety through clearly labeled terminals, strain-relief capabilities, and compatibility with common electrical codes and best practices for UPS hardwire connections.
- Flexible compatibility and scalability: Designed to work with APC UPS models that offer hardwire output options, the kit supports scalable deployments—from single-rack setups to multi-load environments—while preserving the integrity of power protection for critical devices.
Technical Details of APC by Schneider Electric Output Hardwire Kit
- Model/SKU: Availability and exact specifications vary by SKU; consult packing labels or product documentation for your specific unit.
- Electrical rating: The electrical characteristics are determined by the corresponding APC UPS model and installation configuration; refer to the product label and installation manual for exact voltage, current, and conductor requirements.
- Connection type: Hardwired output with terminal block connectors designed for secure, code-compliant wiring to the building distribution system.
- Mounting compatibility: Suitable for installation in rack enclosures, wall-mount cabinets, or dedicated electrical spaces, with included hardware to support common mounting arrangements.
- Wiring materials: Includes copper conductors and termination hardware engineered for reliable electrical connections and long-term performance in standard data-center and office environments.
- Safety and certifications: Certifications and safety ratings are dependent on SKU and regional requirements; verify the specific kit documentation to ensure alignment with local electrical codes and standards.
- Warranty and support: Warranty terms and support options are determined by the SKU and regional policies; check the issuing documentation for precise coverage details.
How to install APC by Schneider Electric Output Hardwire Kit
- Prepare the installation area: Power down the APC UPS and disconnect it from mains power. Confirm that the work area is clean, dry, and free of any hazards, and ensure you follow all local electrical codes and safety guidelines.
- Identify the hardwire connection point: Locate the designated output hardwire connection on your APC UPS model and review the included installation manual for model-specific wiring diagrams and terminal labeling.
- Mount the kit securely: Use the provided mounting hardware to affix the hardwire kit to a suitable surface within an enclosure, cabinet, or adjacent wall space, ensuring that the assembly remains stable during operation.
- Route and prepare conductors: Run the incoming and outgoing conductors from the UPS output to the distribution panel or load centers. Route cables neatly to avoid interference with fans, doors, or other equipment, and secure with strain-relief where applicable.
- Make the electrical connections: Connect line, neutral, and ground conductors to the corresponding terminals on the kit’s terminal block, preserving correct polarity and ensuring tight, vibration-free terminations. Follow the labeling on the kit and UPS for accurate connections.
- Verify conductor sizing and torque: Confirm conductor gauge complies with NEC or local code requirements and torque every terminal to the manufacturer’s specified values to ensure a solid, maintenance-friendly connection.
- Perform a safety check: Inspect all wiring for exposed conductors, secure cable management, and proper grounding. Replace any covers or protective shrouds and re-check clearances around the installation area.
- Power-on test and load check: Reconnect power to the UPS and perform a controlled power-on test. Apply a representative load to confirm normal operation and verify that the UPS output proceeds to the connected distribution path without faults.
- Documentation and labeling: Record the installation details, including the kit SKU, wiring diagram, load distribution, and any region-specific compliance notes. Label the enclosure or panel to reflect the hardwire configuration for future maintenance.
Frequently asked questions
- What is the primary purpose of the APC Output Hardwire Kit? The kit provides a dedicated, hardwire path from an APC UPS output to a building’s electrical distribution, enabling reliable backup power for critical equipment in data centers, telecom rooms, and office environments.
- Is this kit compatible with all APC UPS models? Compatibility depends on the specific UPS model and its hardwire output option. Always verify SKU compatibility with your UPS model and consult the product documentation before purchasing or installing.
- Does installation require a licensed electrician? While some experienced technicians may install the kit, it is strongly recommended that installation be performed by qualified personnel familiar with electrical codes and UPS configurations to ensure safety and compliance.
- What safety standards apply to the hardwire kit? Safety standards and certifications are SKU-dependent and region-dependent. Check the product labeling and official documentation for the exact certifications and code compliance applicable to your installation.
- Can the kit be upgraded or reconfigured for different loads? Yes, the kit is designed to support scalable deployments and can be reconfigured to route power to different distributions as your IT room or data center evolves. Always follow the manufacturer’s installation guidelines when reconfiguring connections.