Description
The APC Power Distribution Module PDM3450CS50-1040 is a versatile, modular solution designed to simplify and accelerate the deployment of power distribution within APC Modular Power Distribution Unit (MPDU) systems. Engineered for data centers, network closets, and enterprise IT environments, this PDM helps teams achieve scalable, reliable power distribution with configurable breaker and connector options tailored to both single-phase and three-phase loads. By integrating seamlessly with APC’s MPDU ecosystem, the PDM3450CS50-1040 minimizes installation complexity, reduces downtime, and supports rapid expansion as equipment footprints and electrical demands evolve. This makes it an ideal choice for organizations pursuing standardized, globally consistent power distribution while maintaining flexibility to adapt to regional electrical standards and load growth.
- Flexible power delivery that supports both single-phase and three-phase configurations to meet diverse data center and IT loads, enabling regional compliance and optimized energy use across locations. The PDM3450CS50-1040 is designed to accommodate a broad range of electrical environments, from compact edge deployments to large-scale MPDU installations, helping administrators standardize on a single distribution platform without sacrificing adaptability.
- Modular, scalable design that lets you mix and match breaker and connector options as your infrastructure expands. Rather than replacing entire distribution hardware, you can upgrade, swap, or add components to extend capacity, improve fault isolation, and enhance maintenance workflows—keeping downtime to a minimum while maintaining strict service levels.
- Seamless integration with APC MPDU solutions for centralized management and streamlined deployment. By aligning with APC’s modular architecture, the PDM3450CS50-1040 supports consistent wiring schemes, labeling, and fault protection across multiple racks and rows, enabling simpler asset tracking, reduce risk of miswiring, and easier firmware and configuration management.
- Ease of installation and day-to-day maintenance, with a compact footprint, standardized mounting, and clear labeling that simplifies wiring and troubleshooting. The module is designed to fit within APC MPDU enclosures with predictable cable routing, aiding technicians during initial deployment and future expansion or relocation tasks.
- Enhanced safety, reliability, and long service life through high-quality construction and proven APC reliability standards. The PDM is built to withstand data-center operational demands, including robust thermal performance, solid electrical isolation, and compatibility with APC’s protective features, delivering dependable power distribution under load and over time.
Technical Details of APC by Schneider Electric PDM3450CS50-1040 Power Distribution Module
- Model: PDM3450CS50-1040
- Brand: APC by Schneider Electric
- Product type: Power Distribution Module (PDM) for APC Modular Power Distribution Unit (MPDU) systems
- Application: Global deployment and expansion of modular power distribution for data centers and IT environments
- Phases supported: Compatible with single-phase and three-phase configurations depending on MPDU setup
- Breaker/Connector options: Configurable with a variety of breakers and connectors; exact options depend on MPDU configuration and regional requirements
- Mounting: Rack-mount capable within APC MPDU enclosures for standardized data-center installations
- Voltage rating: Matched to typical MPDU system voltages; exact value is determined by regional electrical standards and MPDU configuration
- Current rating: Configurable according to MPDU assembly and regional ratings; consult MPDU documentation for exact amperage
- Materials and safety: Built to APC quality standards with protective enclosures, clear labeling, and compliance with industry electrical safety guidelines
- Warranty: Standard APC limited warranty varies by region; terms provided at point of purchase
How to install APC by Schneider Electric PDM3450CS50-1040 Power Distribution Module
- Power down the MPDU enclosure and follow lockout/tagout procedures before beginning installation to ensure safe work conditions and prevent electrical shock.
- Identify the target MPDU chassis and confirm compatibility with the PDM3450CS50-1040 model by verifying the enclosure’s configuration, space, and mounting rails.
- Mount the PDM module within the APC MPDU enclosure according to the manufacturer’s guidelines, aligning any grooves, rails, or mounting holes with the enclosure’s framework to ensure secure fastening.
- Configure the breaker and connector options per the planned load profile. Install breakers and connectors in the designated slots, ensuring proper seating and secure torque values as specified in the MPDU documentation.
- Route and organize cables for single-phase or three-phase feeds, maintaining clean cable management and clear separation from data cables to minimize interference and simplify future servicing.
- Label each circuit clearly, including phase, load description, and destination equipment. This improves maintenance speed, fault diagnosis, and compliance with internal standards and external audits.
- Reconnect power, restore the MPDU power rails, and perform a careful power-on test. Verify that each configured circuit delivers the expected voltage and current, and check for abnormal heating, arcing, or tripping events.
- Document configuration details, including breaker types, circuit mappings, and MPDU firmware versions. Store this information with asset management records to support future expansions and audits.
- Perform a functional test that simulates normal operating loads and a controlled fault scenario to confirm protective features operate correctly and the system isolates faults without impacting non-faulted circuits.
- Establish a routine maintenance plan to inspect connectors, verify torque settings, and monitor thermal performance over time, ensuring ongoing reliability and safety of the distribution network.
Frequently asked questions
- What is the APC PDM3450CS50-1040 best used for? It is a modular power distribution module designed to work within APC MPDU systems, enabling scalable, flexible power distribution for data centers, server rooms, and IT environments. It supports both single-phase and three-phase configurations and allows customization through various breaker and connector options to match load requirements.
- How does it integrate with APC MPDU? The PDM3450CS50-1040 is specifically built to align with APC MPDU enclosures, providing standardized mounting, wiring schemes, labeling, and centralized management. This integration simplifies deployment across multiple racks and locations while maintaining a consistent power distribution architecture.
- Can I upgrade an existing setup with this PDM? Yes, the modular design enables expansion and upgrades by adding or swapping breakers and connectors without replacing the entire MPDU, helping you scale capacity as loads grow and regional requirements evolve.
- Is there a warranty? APC products typically come with a regional warranty. The exact terms vary by country, so check the local distributor or APC support for the precise coverage and duration.
- Where can I find exact electrical specifications? For precise voltage, current ratings, and compatibility details, refer to your MPDU configuration and the official APC product documentation or contact APC support to confirm the correct setup for your data center environment.
Customer reviews