APC by Schneider Electric PDM3450CS50-1680 Power Distribution Module


Price:
Sale price$3,145.43

Description

The APC PDM3450CS50-1680 Power Distribution Module is engineered to simplify the global deployment and scalable expansion of power distribution within modern data centers, telecom rooms, and enterprise IT environments. Designed to work seamlessly with APC Modular Power Distribution Unit (MPDU) solutions, this PDM delivers configurable breaker and connector options that empower operators to distribute power with precision, reliability, and efficiency. Whether you’re outfitting a new facility or upgrading an existing MPDU framework, the PDM3450CS50-1680 is built to support both three-phase and single-phase configurations, enabling flexible, scalable power delivery that aligns with evolving load profiles and uptime requirements. This module is engineered to streamline installation, reduce space usage, and improve serviceability, so teams can focus on uptime, performance, and overall data-center efficiency.

  • Modular versatility for global deployment – The PDM3450CS50-1680 is designed to integrate with APC MPDU ecosystems, helping global IT teams standardize power distribution across regional deployments. Its modular architecture supports diverse breaker and connector options, enabling consistent power architecture whether you’re serving a single rack or an entire data hall. This versatility reduces engineering time, simplifies procurement, and accelerates time-to-value for multi-site projects.
  • Flexible three-phase and single-phase distribution – One of the standout advantages of this module is its ability to supply either three-phase or single-phase power, depending on the chosen configuration. This flexibility ensures critical loads receive stable, balanced power, while maintaining compatibility with a wide range of UPS systems, panel boards, and IT equipment. Operators can tailor configurations to match exact load requirements, improving efficiency and reducing energy waste.
  • Configurable breaker and connector options – A core feature of the PDM3450CS50-1680 is its assortment of breaker and connector options, which lets you customize protection schemes and connectivity to suit specific equipment, cabling, and rack layouts. With careful selection of breakers, you can implement appropriate protection levels for high-density racks, critical servers, and edge deployments, all while preserving space and simplifying maintenance.
  • Rugged design for reliability and longevity – APC Power Distribution Modules are built to endure demanding IT environments. The PDM3450CS50-1680 emphasizes sturdy construction, reliable contacts, and durable housings that resist common office or data-center wear-and-tear. This ruggedness translates into reduced maintenance cycles, fewer service interruptions, and enhanced uptime for essential IT services.
  • Simplified installation and ongoing maintenance – By aligning with APC’s MPDU strategy, this module supports straightforward rack integration, clear labeling, and easy field servicing. The design reduces installation time, simplifies fault isolation, and enables efficient routine checks, all of which support a lower total cost of ownership (TCO) for power distribution in complex IT environments.

Technical Details of APC by Schneider Electric PDM3450CS50-1680 Power Distribution Module

  • Model: APC PDM3450CS50-1680 (Modular Power Distribution Module) — designed to work within APC MPDU ecosystems
  • Configuration: Supports both three-phase and single-phase power distribution based on configured breakers and connectors
  • Mounting: 19-inch rack-mount form factor compatible with standard equipment racks used in data centers and telecom rooms
  • Protection and connectivity: A range of breaker options and connector configurations to tailor protection and cabling paths to specific IT loads
  • Compliance and compatibility: Built to integrate with APC power infrastructure and in line with common electrical protection standards; consult official specifications for exact certification details

How to install APC by Schneider Electric PDM3450CS50-1680 Power Distribution Module

Installing the PDM3450CS50-1680 begins with confirming that the data center or equipment room power architecture is prepared for modular distribution. Begin with a visual inspection of all components, ensuring there are no damaged parts and that the rack space is clean and free of obstructions. A structured approach to installation helps prevent miswiring and allows for faster commissioning once the module is mounted.

1) Prepare the rack and location: Verify there is adequate clearance for serviceability and proper ventilation around the rack. Confirm that the mounting rails are level and securely anchored to support the weight of the distribution module and connected loads. Label any feeds to ensure future maintenance work can be performed quickly and safely.

2) Install the PDM into the MPDU system: Align the PDM3450CS50-1680 with the MPDU chassis and slide it into the intended bay. Secure the module using the manufacturer’s recommended fasteners and verify that the module is seated correctly. Ensure that any interconnections with adjacent modules reflect the intended configuration to avoid fault propagation across the distribution network.

3) Configure breakers and connectors: Based on the planned load profile, select the appropriate breaker and connector options to match single-phase or three-phase distribution needs. Install breakers with attention to correct amperage ratings, ensuring that each branch circuit is protected according to its load and local electrical codes. Route cables and connectors cleanly to minimize stress on terminations and to facilitate future inspections.

4) Connect input power and bus links: Connect input feeds to the PDM in accordance with the provided wiring diagrams. Ensure all connections are secure and torque-defined as per the installation guide. If applicable, install bus links or bridging components to distribute power efficiently between modules or zones in larger MPDU configurations.

5) Verify operation and perform tests: Power up the system in stages, verifying that each distribution path energizes correctly and that breakers trip as expected under simulated fault conditions. Confirm that status indicators and alarms reflect accurate conditions. Document the configuration and keep a record for future audits, maintenance windows, and any regulatory inspections. After initial tests, perform a real-load test within safe and permitted parameters to confirm stability and performance under expected operating conditions.

In addition to these steps, maintain strict adherence to all local electrical codes, safety procedures, and APC’s installation guidelines. If you’re coordinating with a facilities manager or a certified electrician, ensure all work is reviewed and approved before energizing the distribution network. The goal is to deliver reliable, scalable power to critical IT equipment while preserving maximum uptime and simplifying future expansions.

Frequently asked questions

  • What is the APC PDM3450CS50-1680 used for? It is a modular Power Distribution Module designed to distribute electrical power within APC MPDU systems, supporting either three-phase or single-phase configurations with configurable breakers and connectors to match diverse data-center and IT load scenarios.
  • Can the PDM3450CS50-1680 be used in existing data centers? Yes, it is intended to integrate with existing APC MPDU setups, enabling scalable expansion and standardized power distribution across racks and rooms while aligning with APC’s overall protection and management ecosystem.
  • Does this module support both three-phase and single-phase power? Yes, the design accommodates both configurations, with the exact setup determined by the chosen breaker and connector options and the overall electrical system requirements.
  • What installation considerations are important? Focus on proper rack mounting, appropriate breaker selection, correct wiring according to diagrams, and compliance with safety standards. Proper labeling and documentation aid ongoing maintenance and future expansions.
  • Where can I find exact specifications and certifications? For precise electrical ratings, dimensions, certifications, and compatibility details, consult the official APC product datasheet and the distributor’s specifications page. This will ensure the configuration chosen matches your local codes and UPS compatibility requirements.