Description
The APC Power Distribution Module PDM3450CS50-560 is a purpose-built solution for flexible, reliable power distribution within modern IT environments. Designed to work seamlessly with APC Modular Power Distribution Unit (MPDU) platforms, this module enables global deployments and scalable expansion without sacrificing performance or protection. It supports multiple breaker and connector configurations, allowing you to tailor distribution for either three-phase or single-phase loads while maintaining a compact footprint that fits neatly into standard APC MPDU frames and compatible enclosures. With the PDM3450CS50-560, you gain a modular path to predictable power reliability, easier maintenance, and streamlined cable management across data centers, edge facilities, and enterprise IT rooms.
- Flexible configuration for three-phase or single-phase loads: The PDM3450CS50-560 accommodates a wide range of breaker and connector options, enabling precise alignment of distribution topology with your actual load profile. This adaptability helps optimize power delivery, reduce energy waste, and simplify future reconfigurations as workloads evolve. By offering configurable inputs and outputs, the module supports diverse rack layouts and cabinet designs, making it a versatile cornerstone for mixed IT environments.
- Modular expansion and seamless integration: Built to slot into APC MPDU ecosystems, this module supports scalable growth without reworking existing infrastructure. As your data center or network room expands, you can add additional distribution modules to increase capacity while preserving established wiring paths and airflow. The standardized interfaces and backplane compatibility ensure quick installation, faster provisioning, and reduced downtime during upgrades.
- Reliable protection with simple maintenance: The PDM3450CS50-560 provides consistent electrical protection through standardized breaker and connector options, delivering predictable protection for downstream devices. The modular design simplifies inspection, replacement, and routine maintenance, so technicians can perform essential servicing with minimal disruption to critical IT loads. Clear labeling and documentation further aid in fault isolation and proactive management of the distribution system.
- Optimized for space, cooling, and airflow: Engineered for compactness, the module fits efficiently within APC MPDU frames, helping maximize rack density and optimize cooling efficiency. Thoughtful cable routing and connector placement reduce clutter, improve airflow around critical equipment, and support more stable temperatures across the rack. This design approach contributes to higher overall reliability and lower risk of thermal-related issues in busy data centers and telecom facilities.
- Global readiness and serviceability: The PDM3450CS50-560 is designed for universal deployment, with configurations and documentation that support regional variations and international standards. APC’s global service network ensures access to spare parts, technical support, and up-to-date installation guides, making it easier to deploy, maintain, and scale the solution anywhere customers operate. This broad accessibility helps organizations meet uptime commitments and maintain consistent power delivery across multiple sites.
Technical Details of APC by Schneider Electric PDM3450CS50-560 Power Distribution Module
- Model: PDM3450CS50-560
- Function: Modular Power Distribution Module designed to distribute electrical power within APC MPDU installations
- Configuration: Supports both three-phase and single-phase distribution depending on selected breakers and connectors
- Compatibility: Part of the APC Modular Power Distribution Unit (MPDU) family, designed for scalable, standardized deployments
- Inputs/Outputs: Flexible input/output configurations with various breaker and connector options; exact counts depend on SKU and assembly
- Mounting and enclosure: Fits standard APC MPDU frames and compatible enclosures for rack-mount installations
- Electrical standards: Listings and certifications vary by configuration; refer to official datasheet for UL/CE and regional compliance
How to install APC PDM3450CS50-560
- Safety first: Power down all equipment and lock out power sources before handling the module to prevent electrical hazards. Verify that you have the correct personal protective equipment (PPE) and that you follow local electrical codes during installation.
- Prepare the enclosure: Ensure the MPDU frame or rack has available slots and space for cable routing, and verify that the enclosure meets environmental requirements for temperature, humidity, and ventilation. Clear labeling and organized cabling will simplify future maintenance.
- Mount the PDM: Secure the PDM3450CS50-560 into the target MPDU frame or enclosure using the manufacturer’s mounting hardware, aligning connectors with the backplane as specified in the installation guide. Confirm that the unit is firmly seated to prevent vibration or loosening during operation.
- Configure breakers and connectors: Install the appropriate breakers and connector modules for the intended load profile (three-phase or single-phase) and wire them according to the wiring diagram provided by APC. Double-check terminal torque specifications and ensure balance across phases where applicable to maintain optimal performance.
- Power up and test: Reconnect power, power on the system, and perform a basic functional test to ensure correct distribution and protection of downstream devices. Validate that breakers trip properly under fault conditions and document the configuration for future maintenance and audits.
- Documentation and handover: Record the exact breaker configurations, SKU details, and wiring maps in your facility’s asset database. Provide operators with quick-reference guides for routine checks and establish a maintenance schedule to keep the distribution module performing at peak reliability.
Frequently asked questions
- Q: What configurations does the PDM3450CS50-560 support? A: It supports configurable three-phase or single-phase power distribution depending on the installed breakers and connectors, enabling flexible deployment across data centers and network rooms.
- Q: Is the PDM3450CS50-560 compatible with existing APC MPDU systems? A: Yes, it is designed to integrate with APC Modular Power Distribution Unit families, providing scalable expansion within an established MPDU infrastructure.
- Q: How do I know which breakers and connectors to use? A: Breaker and connector options are selected to match the required load and arrangement; refer to the APC installation and configuration guides for guidance on compatible components and configurations for your SKU.
- Q: What are typical installation considerations? A: Ensure proper enclosure space, cable management, cooling, and safety procedures; follow the official installation guide for listing, wiring, and voltage requirements.
- Q: What kind of support is available? A: APC provides product documentation, datasheets, and regional support through their network; warranty terms vary by region and distributor, so check with your reseller for specifics.