Designed for modern data centers and enterprise networks, the APC PDM3450CS50-680 Power Distribution Module delivers scalable, reliable power distribution within APC Modular Power Distribution Unit (MPDU) solutions. This modular distribution module is crafted to simplify deployment, streamline expansion, and optimize energy management across 3-phase and single-phase environments. With flexible breaker and connector options, the PDM3450CS50-680 empowers data center managers to tailor power layouts to exact load profiles, maximize space efficiency, and improve service uptime. Whether you’re consolidating a new data hall or expanding an existing footprint, this PDM is built to integrate seamlessly with APC’s MPDU ecosystem, delivering predictable electrical delivery and centralized control for critical loads.
- Versatile power distribution for APC MPDU: The PDM3450CS50-680 supports both three-phase and single-phase configurations, giving you a flexible foundation to match your data center’s unique topology and future growth plans. Its design enables rapid adaptation to changing workloads, helping you scale without costly rework or downtime.
- Modular and customizable breaker/connector options: Adapt the module with a wide range of breakers and connectors to suit your specific load requirements. This customization ensures optimal protection, simplified maintenance, and space-efficient layouts that maximize rack density and capability.
- Seamless integration with APC MPDU solutions: Engineered to slot directly into APC Modular Power Distribution Units, the PDM3450CS50-680 provides consistent interfaces, coordinated monitoring, and unified power management across the entire MPDU family for easier planning and operation.
- Enhanced reliability for critical environments: Built to withstand demanding data center conditions, the module emphasizes robust enclosure design, secure mounting, and dependable electrical performance, helping to minimize unscheduled downtime and extend asset life.
- Optimized energy management and monitoring: When paired with APC power management tools, the PDM3450CS50-680 enables granular insight into load distribution, breaker status, and energy usage, empowering operators to optimize cooling, capacity planning, and operational efficiency.
Technical Details of APC PDM3450CS50-680
- Model: PDM3450CS50-680
- Product family: APC Power Distribution Module for Modular Power Distribution Units
- Configuration support: 3-phase and single-phase distribution options
- Breaker/accessory options: Flexible assortment of breakers and connectors to tailor to installation needs
- Compatibility: Designed for seamless integration with APC MPDU solutions for scalable, centralized power control
- Application environments: Data centers, server rooms, telecom shelters, and network closets requiring robust power distribution
- Compliance and safety: Built to meet industry electrical standards and APC’s reliability expectations for critical infrastructure
How to install APC PDM3450CS50-680
- Plan the distribution layout: Verify load requirements and confirm compatibility with your APC MPDU chassis and busbar configuration. Ensure you have the correct breakers and connectors chosen for single-phase or three-phase deployment.
- Power down the MPDU system: Follow lockout-tagout procedures to safely de-energize equipment before installation. Confirm that the workspace is free of live electrical hazards.
- Mount the PDM into the MPDU frame: Use the provided mounting hardware to secure the PDM3450CS50-680 within the MPDU enclosure, aligning it with the designated mounting points and ensuring solid mechanical stability.
- Connect breakers and feeders: Attach the selected breakers and feeders according to your distribution plan. Ensure correct phase alignment for three-phase configurations and proper conductor sizing for single-phase runs to maintain balance and efficiency.
- Power up and verify operation: Restore power, then verify continuity, voltage levels, and breaker status using APC monitoring tools. Confirm that all feeds are providing correct voltage and that protective devices are functioning as intended.
Frequently asked questions
- What is the APC PDM3450CS50-680 used for? It is a power distribution module designed to be used with APC Modular Power Distribution Units to distribute power to IT equipment in data centers, server rooms, and network closets, with configurable breakers and connectors for flexible deployment.
- Can it support 3-phase power distribution? Yes. The module is engineered to support both three-phase and single-phase distribution, enabling scalable layouts that match different data center topologies and load profiles.
- How does it integrate with APC MPDU solutions? The PDM3450CS50-680 is built to slot into APC MPDU families, providing a consistent interface and centralized power management across the distribution system for easier planning and monitoring.
- What are the benefits of using this PDM in a data center? Benefits include modularity for easy expansion, customizable breakers and connectors for precise protection, improved space efficiency, enhanced reliability for critical loads, and better energy visibility when paired with APC power management software.
- How should I plan maintenance and upgrades? Plan ahead by mapping your load growth and stockpiling compatible breakers/connectors. Regularly monitor breaker status and energy metrics with APC monitoring tools to anticipate capacity needs and perform timely upgrades with minimal downtime.