APC by Schneider Electric PDM3520IEC309-260 Power Distribution Module


Price:
Sale price$859.54

Description

Introducing the APC by Schneider Electric PDM3520IEC309-260 Power Distribution Module—a touch-safe, expandable power distribution solution designed to streamline capacity growth without the downtime or hot work traditionally required. This integrated module combines a robust circuit breaker, a ready-to-use power cord, secure power connections, and built-in circuit monitoring to deliver safe, reliable expansion for data centers, labs, and industrial environments. Engineered by Schneider Electric’s trusted APC brand, the PDM3520IEC309-260 focuses on safeguarding personnel while ensuring continuous power availability for critical loads. It’s the ideal upgrade for facilities seeking scalable, maintenance-friendly power distribution that minimizes disruption during expansion or reconfiguration.

  • Touch-safe design for safer expansions—Expand your distribution network without exposing technicians to live conductors or requiring hot work, helping you maintain safety protocols while growing capacity.
  • Integrated protection and monitoring—Includes a circuit breaker, monitoring circuitry, and a dedicated power connection to protect circuits and provide real-time status feedback on voltage, current, and load balance.
  • Easy expansion with reliable reliability—Engineered to pair with APC and Schneider Electric systems, enabling seamless addition of distribution modules without system shutdowns or complex interlocks.
  • IEC 309 compatibility for rugged environments—Designed to operate in industrial settings with robust connectors and enclosures that resist wear, moisture ingress, and temperature swings while delivering consistent performance.
  • Versatile applications—A smart choice for data centers, healthcare labs, manufacturing floors, and research facilities where scalable, safe power distribution is critical to uptime and safety.

Technical Details of APC by Schneider Electric PDM3520IEC309-260 Power Distribution Module

  • Model: PDM3520IEC309-260
  • Product type: Touch-safe Power Distribution Module with integrated circuit breaker and circuit monitoring
  • Input/output connection: IEC 309-260V configuration designed for reliable, rugged power connections in demanding environments
  • Protection: Built-in circuit breaker to safeguard downstream circuits and simplify rapid isolation during maintenance
  • Monitoring capabilities: Real-time circuit monitoring to track load, voltage, and health of connected circuits
  • Power cord and cord management: Includes a dedicated power cord and secure connection hardware for clean, safe installation
  • Safety and compliance: Touch-safe construction with compliance considerations suitable for data centers, labs, and industrial settings
  • Enclosure and durability: Rigorously built to endure demanding environments while maintaining performance and uptime

How to install APC by Schneider Electric PDM3520IEC309-260 Power Distribution Module

Installing the PDM3520IEC309-260 is straightforward and designed to minimize downtime while preserving safety. Follow these high-level steps to add this module to your distribution setup with confidence:

  • Plan and assess: Review your current power distribution layout, identify expansion needs, and confirm compatibility with IEC 309-260V configurations. Verify that the mounting location provides adequate ventilation and access for monitoring indicators.
  • Prepare mounting environment: Choose a secure, vibration-minimized rack or panel location. Ensure mounting hardware is native to your enclosure and that there is clearance for cables, the power cord, and the monitoring display.
  • Mount the module: Attach the PDM3520IEC309-260 using the supplied hardware. Secure fasteners to prevent loosening from vibration or handling. Ensure the module sits level and aligned with adjacent modules to maintain tidy cable routing.
  • Connect power and circuits: Connect the input power cord to a properly rated IEC 309 source as per local electrical codes. Attach the downstream circuits to the PDM’s distribution terminals, ensuring proper torque on connections and clear labeling for every circuit.
  • Enable protection and monitoring: Engage the built-in circuit breaker and verify that the monitoring indicators activate. Confirm that voltage, current, and load indicators reflect the expected values once power is applied.
  • Verify operation and safety: Power up the system with no critical loads initially. Observe for any abnormal readings or trip conditions. Gradually introduce loads while monitoring performance to ensure stable operation and that no overheating occurs in the enclosure.
  • Documentation and labeling: Update your electrical diagrams and labeling to reflect the new distribution module. Record the PDM’s model, input configuration, and circuit assignments for future maintenance and audits.

Frequently asked questions

  • What is the APC PDM3520IEC309-260 used for? It is a touch-safe power distribution module designed to expand power distribution capacity without requiring hot work or system shutdowns, making it ideal for rapid, safe scalability in data centers, labs, and industrial environments.
  • Does the PDM3520IEC309-260 include monitoring? Yes. It provides circuit monitoring to give real-time visibility into load, voltage, and circuit health, helping you optimize performance and uptime.
  • Is the module safe to install in live environments? The touch-safe design reduces exposure to live conductors during expansion, and it is engineered to support safe installation with adherence to relevant safety guidelines. Always follow local electrical codes and safety procedures during any installation.
  • Can this PDM be integrated with existing APC/Schneider Electric systems? Yes. The PDM3520IEC309-260 is designed to complement APC and Schneider Electric ecosystems, enabling seamless expansion with consistent performance and management tools.
  • What environments is this module suited for? It is well-suited for data centers, healthcare facilities, laboratories, manufacturing floors, and other settings where scalable, reliable, and safe power distribution is crucial to uptime.
  • What information should I have before purchasing? Confirm the required voltage and current ratings, the number of circuits to support, enclosure compatibility, and whether you need in-built monitoring for proactive maintenance.

Customer reviews