APC by Schneider Electric Rack Air Removal Unit SX Ducting Kit


Price:
Sale price$293.94

Description

The APC by Schneider Electric Rack Air Removal Unit SX Ducting Kit delivers focused, efficient cooling for Netshelter SX and VX enclosures. Designed to mount on the rear of the cabinet, this kit extends your rack height to 42U, 47U, or 48U while preserving valuable front-face space for your critical servers, storage, and networking gear. Its innovative, user-friendly design enables fast installation by almost anyone, helping data centers and office server rooms optimize airflow, improve cooling performance, and reduce energy use without sacrificing space or accessibility.

  • Rear-mount versatility for Netshelter SX/VX enclosures – This ducting kit is purpose-built to attach securely to the rear of APC Netshelter SX and VX enclosures, integrating seamlessly with your existing rack system. By mounting at the back, you gain available front-side real estate for high-density equipment while maintaining a clean, organized cabinet interior. The design supports a flexible range of rack heights, enabling precise alignment with 42U, 47U, or 48U configurations to match your current deployment and future growth.
  • Space-saving, front-face preservation – Because the cooling infrastructure is positioned at the rear, front panel space remains unobstructed for server blades, storage shelves, and patch panels. This layout simplifies cable management, improves accessibility for maintenance, and reduces the need for overcrowding inside the enclosure. The result is better air distribution, easier hot-aisle containment, and a neater, more professional data center footprint.
  • Fast and intuitive installation – The SX Ducting Kit is engineered for quick, straightforward installation, minimizing downtime and enabling non-specialist personnel to complete setup with confidence. The modular frame and clearly labeled mounting points streamline assembly, while standardized hardware and documented steps help ensure a reliable installation that aligns with APC’s rigorous design standards.
  • Efficient airflow with variable-speed fans – At the heart of the kit is a cooling path that actively draws hot air from the enclosure and directs it through a controlled ducting system. The inclusion of variable-speed fans allows precise control of airflow to match the thermal load, optimizing cooling performance while reducing energy consumption. This dynamic cooling strategy helps prevent hot spots, supports more uniform temperatures across equipment, and can contribute to lower operating costs over time.
  • Durable construction and reliable performance – Built to withstand the rigors of data center environments, the ducting kit uses robust materials and tight tolerances to maintain airflow efficiency over time. The rear-mount framework is designed for stability, reducing vibration and noise while preserving the enclosure’s structural integrity. This combination of durability and thoughtful design ensures long-term reliability even in high-availability deployments.

Technical Details of APC by Schneider Electric Rack Air Removal Unit SX Ducting Kit

  • Get this information from the "specifications" section of the product from https://ec.synnex.com/ using product "UPC" or "SKU" as reference

How to Install APC Rack Air Removal Unit SX Ducting Kit

  • Gather the required mounting hardware and verify compatibility with your Netshelter SX or VX enclosure. Ensure the enclosure is de-energized and available for service to prevent any safety hazards during installation.
  • Position the ducting kit at the rear of the enclosure, aligning mounting holes with the appropriate rails or brackets. Use the supplied screws and brackets to secure the frame firmly to the back of the cabinet, taking care to avoid overtightening that could deform mounting points.
  • Attach the ducting components to create a sealed, direct airflow path from the enclosure interior to the external ducting run. Confirm seals at all joints to minimize air leakage and maximize cooling efficiency. If optional accessories are included, integrate them according to the installation guide to tailor airflow for your specific rack layout.
  • Connect the fans and power supply as specified in the installation instructions. Configure the variable-speed controls to balance airflow with the thermal load inside the rack, then test operation to confirm steady airflow through the ducting path and out of the rear of the enclosure.
  • Perform a startup test by loading representative equipment into the enclosure and monitoring inlet and outlet temperatures. Fine-tune fan speeds as needed to maintain stable temperatures across critical components while maintaining acceptable noise levels and energy use. Confirm that the rack remains accessible for routine maintenance and that cable routes remain clear of ducting and moving parts.
  • Document the installation for future maintenance, including rack height (42U/47U/48U), mounting points used, ducting path configuration, and fan speed settings. Establish a routine to periodically inspect seals, fasteners, and airflow integrity to sustain optimal cooling performance over time.

Frequently asked questions

  • Q: Is the Rack Air Removal Unit SX Ducting Kit compatible with Netshelter SX and VX enclosures? A: Yes. The kit is designed to mount on Netshelter SX or VX enclosures to support rear-mounted cooling and preserve front-rack space.
  • Q: What rack heights does the kit accommodate? A: It extends to support 42U, 47U, or 48U rack heights, allowing flexible deployment for your existing and future equipment needs.
  • Q: How do variable-speed fans improve cooling efficiency? A: Variable-speed fans adjust airflow in response to thermal load, delivering precise cooling where it’s needed while reducing energy consumption compared with fixed-speed options.
  • Q: Where is the ducting kit mounted? A: The frame mounts to the rear of the enclosure, enabling efficient air removal without occupying valuable front-panel space.
  • Q: Does installing this kit require specialized tools? A: The design emphasizes fast, easy installation, often achievable by technicians familiar with APC enclosure systems, with standard mounting hardware included in the kit.
  • Q: What maintenance is required after installation? A: Periodic checks of seals, fasteners, and fan operation are recommended to preserve airflow efficiency and cooling performance over time.