APC by Schneider Electric Rack PDU 2G Metered ZeroU 10kW 208V — 36 C13 & 6 C19
APC Metered Rack PDU 2G delivers reliable, scalable rack power distribution from a single input to a wide array of receptacles, keeping critical IT equipment powered with precision. Its metered design provides real-time energy data and alarm capabilities that help IT teams prevent circuit overloads and power outages that can disrupt servers, storage devices, and network gear. The ZeroU form factor ensures a compact footprint that fits neatly into standard 19-inch racks, preserving valuable rack space for servers and cabling while delivering high-density power distribution. With a robust 10.0 kW capacity at 208 V, this PDU is ideal for data centers, colocation facilities, edge deployments, and lab environments where uptime, efficiency, and proactive power management matter. Built by APC, a trusted leader in data center infrastructure, the Rack PDU 2G combines reliability, visibility, and easy integration with DCIM tools to simplify energy management and improve operational resilience.
- High-density power distribution: Capable of delivering up to 10 kW at 208 V to support a fleet of servers, storage devices, and networking equipment, all from a single, centralized rack power source. With 36 C13 outlets and 6 C19 outlets, you can provision a flexible mix of IT devices while keeping cabling organized and accessible.
- Metering and remote monitoring: Real-time energy usage data, voltage, current, and power metrics are available for monitoring and capacity planning. The metered design enables precise chargeback reporting and helps you identify hotspots before they impact performance.
- Space-saving ZeroU design: The ZeroU form factor preserves front-of-rack space by mounting vertically in the 19-inch rack, freeing chassis depth for critical equipment and simplifying cable management without compromising accessibility or safety.
- Proactive protection with alarms: User-defined alarms for overloads, overcurrent, voltage fluctuations, and temperature thresholds provide timely alerts to IT staff, enabling rapid response and reducing the risk of unexpected downtime.
- Reliability and scalability: Built to the APC standard of durability and firmware integrity, with optional network management card support and compatibility with DCIM workflows for centralized monitoring, alerting, and reporting across your data center.
Technical Details of APC by Schneider Electric Rack PDU 2G
- Model: APC Rack PDU 2G Metered ZeroU
- Output receptacles: 36 x C13, 6 x C19
- Input voltage: 208 VAC
- Power rating: 10.0 kW
- Form factor: ZeroU rack-mountable
- Metering: Real-time energy usage with remote monitoring and alarm capabilities
How to install APC Rack PDU 2G
Before installation, ensure your rack and power infrastructure meet the PDU’s specifications and that you have a compliant 208 V power source available. Begin by determining the best mounting location in your rack, typically at the rear or side rail where cables can be routed cleanly. Use the included hardware to mount the PDU in the rack’s 19-inch chassis and verify that the unit is securely fastened and level. Route power cabling from the 208 V supply to the PDU input, making sure to follow all electrical codes and labelling requirements. Connect the 36 C13 and 6 C19 outlets to the IT devices, keeping high-current loads organized to avoid cable congestion. If you plan to enable remote monitoring, install the appropriate management interface or network management card per the product’s documentation and connect it to your management network. Configure metering settings, alarm thresholds, and access permissions to align with your IT and facilities policies. Finally, perform a controlled power-up sequence and monitor the readings to confirm accurate measurement, outlet functionality, and proper alarm behavior. Regularly inspect filters, cabling, and airflow around the PDU to maintain optimal cooling and performance in your rack environment.
Frequently asked questions
- Q: What outlets does this PDU provide? A: It features 36 C13 receptacles and 6 C19 receptacles to support a broad mix of servers, storage, and networking equipment.
- Q: What is the input power and total power capacity? A: The PDU is designed for 208 V input with a total power capacity of 10.0 kW, enabling you to power a sizable number of devices from a single unit.
- Q: Can I monitor this PDU remotely? A: Yes. The Metered PDU 2G includes real-time metering and supports remote monitoring, with alarms that can be configured to notify IT staff via your preferred management tools or network interfaces.
- Q: What does ZeroU mean for installation? A: ZeroU indicates that the PDU occupies no front rack units in terms of mounting depth, allowing you to maximize space for equipment while maintaining easy access to power outlets and cabling.
- Q: Is this PDU compatible with network management cards? A: APC PDUs typically support optional network management cards or integrated management interfaces to enable advanced monitoring, alerting, and DCIM integration. Check the product’s documentation for compatibility and installation specifics in your region.