Description
Compact, reliable, and designed for high-density deployments, this APC by Schneider Electric Rack PDU delivers dependable power distribution for critical IT gear. The Zero U footprint and tool-less mounting make it a perfect fit for NetShelter enclosures, while the 30A, 100V configuration supports up to 3000 W of continuous power to 24 devices. Built for data centers, server rooms, and office lab environments, this basic rack PDU simplifies cable management and preserves precious rack space without sacrificing performance.
- Space-saving Zero U design with tool-less mounting for effortless installation inside NetShelter enclosures, leaving full floor space in the rack.
- High-capacity power delivery supports 30A at 120V (3000 W) to keep servers, storage, and networking gear running smoothly.
- Flexible inputs and outputs featuring a NEMA L5-30P input and 24 x NEMA 5-15R outlets for common IT equipment.
- Durable and reliable APC design from Schneider Electric, built to handle the demands of data centers and enterprise environments.
- Ideal for NetShelter enclosures and data-center racks offering plug-and-play power distribution with minimal footprint and straightforward installation.
Technical Details of APC by Schneider Electric Rack PDU, Basic, Zero U, 30A, 100V, (24) 5-15
- Input: NEMA L5-30P
- Output: 24 x NEMA 5-15R
- Voltage: 120 VAC
- Current rating: 30 A
- Maximum power: 3000 W
- Form factor: 0U, rack-mountable
- Mounting: Toolless mounting compatible with NetShelter Enclosures
- Design: Basic rack PDU for straightforward power distribution
how to install APC by Schneider Electric Rack PDU
To install this Rack PDU Basic Zero U in a compatible NetShelter enclosure, follow these steps. Ensure the enclosure is powered off and that you have adequate clearance for cable routing.
1) Confirm enclosure compatibility and choose an appropriate 0U space within the rack for the PDU.
2) Align the PDU with the rack rails and engage the tool-less mounting mechanism until it seats securely.
3) Slide the PDU into place until it is firmly mounted and cannot be pulled out easily.
4) Connect the NEMA L5-30P plug from the PDU to a properly rated power source or UPS outlet. Ensure the power source can supply up to 30 A at 120 VAC.
5) Begin populating the 24 outlets (NEMA 5-15R) with IT equipment, distributing load evenly across outlets, and verifying that total draw remains within the 3000 W rating. Use appropriate cable management to maintain airflow and accessibility.
Frequently asked questions
What outlets are included on this PDU?
The PDU provides 24 x NEMA 5-15R outlets for powering standard IT devices.
What is the input plug and current rating?
The PDU uses a NEMA L5-30P input and supports up to 30 A at 120 V (120 VAC).
What does Zero U mean for installation?
Zero U indicates a 0U footprint in the rack, allowing you to mount the unit without occupying vertical rack space, preserving valuable height for equipment. It is designed for tool-less mounting into NetShelter enclosures.
Is this PDU compatible with NetShelter enclosures?
Yes. The PDU is designed for easy integration with NetShelter enclosures using tool-less mounting, enabling quick installation without additional hardware.
What is the total power capacity and typical use case?
The PDU supports up to 3000 W at 120 V, suitable for distributing power to multiple servers, storage devices, and networking gear in data centers, server rooms, or enterprise labs where space efficiency and reliable power distribution are essential.
Customer reviews
Showing - Of Reviews
