APC by Schneider Electric Rack PDU, Switched, 1U, 12A/208V, 10A/230V, (8)C13


Price:
Sale price$768.78

Description

APC Switched Rack PDU, 1U, 12A/208V, 10A/230V, (8) C13

This APC by Schneider Electric Switched Rack PDU delivers compact, reliable power distribution for modern data centers and high-density server rooms. Built to simplify power management, this 1U unit combines robust electrical protection, flexible voltage compatibility, and sophisticated remote management to optimize uptime, cooling efficiency, and overall data center performance. Designed for dense racks and demanding workloads, it provides essential control over power delivery with a focus on scalability, security, and operational insight. Whether you are provisioning a single rack or coordinating power across multiple enclosures, this switched PDU helps you align power usage with business priorities, reduce energy waste, and keep critical equipment running smoothly.

The PDU’s 1U form factor is purpose-built for space-constrained environments, ensuring you maximize your rack real estate without compromising on power capacity. With eight IEC C13 outlets, you can support a broad mix of servers, storage devices, and network equipment while keeping cabling organized and accessible. The dual-voltage capability—12A at 208V and 10A at 230V—gives you the versatility to match regional electrical standards and evolving load profiles. Network management is a cornerstone of this unit, enabling you to configure, monitor, and control power delivery remotely from your existing monitoring systems or data center infrastructure. This capability is especially valuable for remote sites, distributed deployments, and environments where on-site visits are costly or disruptive. In short, APC’s Switched Rack PDU helps you improve visibility into power usage, implement smarter load distribution, and respond quickly to power events before they impact application performance.

  • Compact 1U form factor provides eight IEC C13 outlets for high-density racks while preserving valuable space for critical IT gear and future expansion.
  • Dual-voltage support (12A at 208V, 10A at 230V) offers flexible deployment across regions and changing load requirements without swapping hardware.
  • Switched PDU with network management enables remote configuration, real-time monitoring, and centralized control of power delivery across the rack.
  • Intelligent features support energy efficiency, load management, alarms, and event reporting to help meet uptime targets and sustainability goals.
  • Rugged rack-mount design built for data centers, telecom rooms, and space-constrained facilities where reliability and serviceability are essential.

Technical Details of APC by Schneider Electric Rack PDU (8 C13)

  • Output connections: 8 x IEC C13 outlets
  • Output power: up to 2,300 W at 230 V (10 A) or up to 2,496 W at 208 V (12 A)
  • Input voltage and current: 208 V at 12 A or 230 V at 10 A (model configuration dependent)
  • Form factor: 1U rack-mountable
  • Management: network-enabled for remote configuration and monitoring
  • Protection and alerts: overload protection and event notifications to support proactive maintenance

how to install APC by Schneider Electric Rack PDU

Installing this Switched Rack PDU is straightforward and designed to integrate with standard data-center practices. Begin by selecting a compatible 19-inch rack location with adequate ventilation and clearance for service access. Secure the PDU to the rack rails using the included mounting hardware, ensuring the unit is level and stable. Connect the PDU’s input to the appropriate power source for your region—208 V or 230 V—using a code that matches your facility’s electrical standards and amperage. Once mounted and powered, attach your IT devices to the eight IEC C13 outlets, grouping cables to minimize clutter and maximize airflow. Configure the remote management interface by connecting the PDU to your network, then establish authentication and access permissions for authorized personnel. Finally, verify that the PDU is reporting power status, throughput, and any alarms through your management console, and perform a startup test to confirm proper operation and outlet responsiveness.

  • Mount the PDU securely in a standard 19-inch rack, ensuring sufficient clearance for ventilation and maintenance access.
  • Connect the input power cord to the appropriate 208 V or 230 V supply, using a compliant plug and circuit protection as required by local electrical codes.
  • Plug your servers, switches, and other devices into the eight IEC C13 outlets, organizing cables for airflow and future expansion.
  • Configure network management settings through the PDU's interface or your centralized management system, enabling monitoring, alerts, and access control.
  • Run a verification test to confirm that outlets respond to remote commands and that power metrics are accurately reported in your monitoring tools.

Frequently asked questions

  • Q: What outlets does this PDU provide? A: It offers eight IEC C13 outlets for powering a range of servers, storage devices, and network equipment.
  • Q: What voltages and currents are supported? A: The unit supports 208 V at up to 12 A or 230 V at up to 10 A, depending on the model configuration.
  • Q: Can I manage the PDU remotely? A: Yes. The PDU is network-enabled and designed for remote configuration, monitoring, and control from compatible management systems.
  • Q: Is the unit suitable for high-density racks? A: Yes. Its 1U footprint and eight outlets are optimized for dense deployments while preserving airflow and accessibility.
  • Q: What kind of protections are included? A: Overload protection and alerting are provided to help prevent downtime and support proactive maintenance.