Description
APC by Schneider Electric Rack PDU, Switched, Zero U, 12.5kW, 208V
Experience the ultimate in power management with the APC by Schneider Electric Rack PDU, Switched, Zero U, 12.5kW, 208V. This state-of-the-art power distribution unit is engineered for modern data centers and server rooms, delivering unmatched reliability, efficiency, and control. The zero-U design minimizes rack footprint while maximizing space for your equipment, cables, and airflow. With a robust 12.5 kW capacity at 208V, it is capable of supporting dense server configurations, virtualization hosts, hyper-converged systems, and networking gear in scalable, modular fashion. The combination of 21 C13 outlets and 3 C19 outlets offers flexible distribution for mixed loads, enabling you to consolidate power management without compromising outlet availability. This Switched PDU provides intelligent outlet control that helps you fine-tune power usage, perform load shedding, and remotely manage reboot sequences, all from a centralized interface. For data centers and server rooms where uptime, monitoring, and energy efficiency are critical, this APC PDU brings enterprise-grade performance, predictable power delivery, and straightforward integration with existing IT management ecosystems.
- Zero-U footprint for maximum rack density: A compact, front-access design that sits unobtrusively in your 19-inch rack, freeing space for servers, storage, and network gear while keeping cable management neat and airflow unobstructed.
- High-capacity, 208V power distribution: Delivers up to 12.5 kW of reliable power, accommodating dense compute environments and ensuring consistent performance across connected devices.
- Outlet-level switching for remote power control: Per-outlet switching capability enables remote power cycling, load shedding, and granular control to minimize downtime and optimize maintenance windows, all without entering the data center floor.
- Flexible outlet configuration: Features 21 C13 outlets and 3 C19 outlets to support mixed equipment footprints—from rack servers and storage arrays to switches, routers, and virtualization appliances—while keeping critical devices within arm’s reach.
- Long, reliable power cord for versatile deployment: Includes a 10-foot cord that provides ample reach for standard data center layouts and rack layouts with distant power sources, reducing the need for additional extension cords or adapters.
Technical Details of APC by Schneider Electric Rack PDU, Switched, Zero U, 12.5kW, 208V, (21)C13&(3)C19; 10' Cord
- Power rating: 12.5 kW total capacity for high-density compute and storage environments.
- Input voltage: 208V supply suitable for data centers and professional IT deployments.
- Outlet count and types: 21 x C13 outlets and 3 x C19 outlets for flexible device connections.
- Form factor: Zero-U (0U) rack-mount design to maximize rack space for equipment and airflow.
- Cord length: 10-foot power cord to accommodate varied rack placements and room layouts.
how to install APC by Schneider Electric Rack PDU, Switched, Zero U, 12.5kW, 208V
- Prepare the rack: Confirm you have the appropriate 19-inch rack space and sturdy mounting rails. Ensure there is clearance for airflow in front of the devices and behind the PDU to avoid heat buildup.
- Mount the PDU: Install the zero-U PDU along the rack’s vertical rails, ensuring secure attachment with the provided mounting hardware. Verify that the unit sits flush and remains stable during cable management tasks.
- Connect to power: Plug the 10' cord into a suitable 208V circuit with adequate amperage as specified by your data center’s electrical plan. Use proper circuit protection and verify that the circuit can handle the PDU’s 12.5 kW load with headroom for startup surges.
- Attach IT devices: Connect servers, storage, and networking gear to the C13 and C19 outlets. Group devices by current draw and criticality to facilitate balanced loading and targeted outage testing when needed.
- Configure and verify: Access the PDU’s management interface to configure outlet visibility, remote control permissions, and alert thresholds. Validate that per-outlet switching is functional by performing controlled power cycles and verifying device reboot behavior. Run an initial load check to confirm the overall system stays within the 12.5 kW limit under expected peak conditions.
Frequently asked questions
- What does “Zero U” mean for this PDU? Zero-U means the unit is designed to occupy only the vertical space of the rack rails (0 rack units), preserving front-panel clearance and maximizing available space for servers and other equipment.
- What outlets are available on this PDU? The unit provides 21 C13 outlets and 3 C19 outlets, enabling a mix of devices with different power connector types within a single PDU.
- What voltage does this PDU use? It operates at 208V, which is common in many data centers and provides efficient power delivery for high-density deployments.
- Can I control individual outlets remotely? Yes. This is a switched PDU, allowing remote power control at the outlet level to reboot devices, balance loads, and manage maintenance windows without on-site visits.
- Is the cord length sufficient for typical rack layouts? The 10-foot cord is designed to accommodate standard data center configurations, reducing the need for extra extension cords and simplifying cable management.
- Is remote monitoring supported? The PDU is designed for integrated power management workflows and can typically be managed via standard APC/SCHNEIDER Electric management interfaces to monitor outlet status, energy usage, and alerts, aligning with broader data center infrastructure management strategies.