Description
APC by Schneider Electric RD25KW Humidity Sensor
Protect your most valuable IT assets with the APC by Schneider Electric RD25KW Humidity Sensor. Engineered for reliability in data centers, server rooms, and multimedia environments, this sensor delivers precise humidity monitoring that helps prevent condensation, avoid static buildup, and extend the life of critical equipment. The RD25KW is designed to integrate seamlessly with APC’s environmental monitoring ecosystem, empowering you to maintain optimal humidity levels with confidence and ease.
Humidity control is not just about comfort—it’s a foundational element of equipment reliability. Excess humidity can accelerate corrosion and promote mold growth, while low humidity increases the risk of electrostatic discharge that can damage sensitive electronics. The RD25KW humidity sensor is purpose-built to provide accurate, real-time readings that feed into your building management or data center infrastructure monitoring (DCIM) system. By actively tracking moisture levels, you can implement automated alerts, trend analysis, and proactive cooling or dehumidification strategies. When your humidity stays within the recommended range—typically around 45% to 55% for many data center environments—the probability of equipment failures drops significantly and uptime improves.
Designed for simple deployment, the RD25KW is compact, rugged, and engineered to operate in demanding IT spaces. Its robust construction tolerates the vibrations, dust, and temperature variations common to data centers, while offering straightforward installation that minimizes downtime. When paired with APC’s monitoring solutions, it becomes a single, scalable component in a broader environmental management strategy that covers temperature, airflow, energy consumption, and more.
Key to its appeal is compatibility. The RD25KW is built to work within APC’s suite of sensors and controllers, enabling administrators to consolidate data in a single dashboard. This integration reduces complexity, speeds the detection of anomalies, and supports efficient capacity planning as your infrastructure grows. With intuitive calibration options and reliable performance, the RD25KW helps you maintain precise humidity targets without constant manual intervention.
- Precise humidity sensing with a wide 0–100% RH range and high accuracy to detect even small changes that could impact sensitive equipment.
- Rugged, compact design engineered for data center rack environments, with secure mounting options and resistance to dust and vibration.
- Seamless APC ecosystem integration compatible with EcoStruxure and APC environmental monitoring platforms for centralized control and alerting.
- Low power, easy installation designed for reliable operation with minimal cabling, enabling fast deployment in new or existing infrastructure.
- Alarms, alerts, and trend data provide proactive notifications and historical insights to help prevent condensation, corrosion, and downtime.
Technical Details of APC by Schneider Electric RD25KW Humidity Sensor
The Technical Details below summarize the core specifications typically associated with the RD25KW humidity sensor and its role within APC’s environmental monitoring framework. These details help IT teams and facilities engineers assess compatibility with existing infrastructure and plan for expansion. For the most accurate, up-to-date values, reference your purchasing documentation and APC’s official data sheets.
- Model: RD25KW Humidity Sensor
- Sensor Type: Relative Humidity (RH) sensor
- Humidity Range: 0–100% RH, non-condensing
- Accuracy: ±3% RH (typical, 0–90% RH), broader accuracy at higher humidity levels
- Output / Interface: Analog output suitable for APC monitoring inputs (commonly 0–10 V DC, compatible with APC controllers and dashboards)
- Power Supply: 24 V DC nominal (compatible with standard APC rack infrastructure power configurations)
- Operating Temperature Range: 0°C to 60°C (32°F to 140°F)
- Enclosure / Mounting: Compact form factor with mounting options designed for rack or wall installations in IT environments
- Compliance and Certifications: Built to meet data center standards for reliability and interoperability with APC ecosystem products
How to Install APC by Schneider Electric RD25KW Humidity Sensor
- Choose a strategic location within the data center or server room that represents typical ambient conditions for accurate readings, avoiding direct airflow from vents or near heat sources.
- Mount the RD25KW securely using the provided brackets or mounting hardware. Ensure the sensor face is unobstructed and accessible for calibration and maintenance.
- Connect power to the RD25KW using the standard 24 V DC supply compatible with APC infrastructure. Verify secure, clean connections to prevent signal loss.
- Wire the analog output (0–10 V DC) to the corresponding input on your APC environmental monitoring device or DCIM interface. Confirm the signal ranges match the receiving equipment.
- Power up the unit and access the APC monitoring dashboard. Calibrate the sensor if required and set alert thresholds for humidity levels outside your defined comfort zone (for example, alert at 45% and 60%).
- Test alerts and validate readings by simulating environmental changes. Ensure that notifications are delivered to the right operators and that data is visible in your centralized monitoring platform.
- Document installation details, including location, wiring, and threshold settings, to simplify future maintenance and audits.
Frequently asked questions
- What environments is the RD25KW humidity sensor designed for? It is designed for data centers, server rooms, network closets, and other critical IT spaces where precise humidity control helps protect equipment and optimize performance.
- How does humidity monitoring benefit data center operations? Maintaining stable humidity reduces the risk of electrostatic discharge, corrosion, and condensation, which in turn lowers the likelihood of equipment failures and unplanned downtime. It also supports energy-efficient cooling by informing dehumidification needs.
- What kind of alerts can I expect from the RD25KW? The sensor provides real-time humidity readings and can trigger alarms or notifications when readings breach user-defined thresholds, enabling rapid response and automated control through APC’s monitoring ecosystem.
- Is the RD25KW compatible with EcoStruxure and APC monitoring? Yes, it is designed to integrate with APC’s monitoring platforms, allowing you to centralize environmental data, dashboards, and alerts for easier management and planning.
- Do I need to calibrate the RD25KW after installation? Calibration may be required depending on your system’s setup and environment. Use APC software tools to calibrate if recommended by the documentation and to ensure readings align with reference measurements.
- Where can I find more detailed specifications? For the most accurate and current specifications, consult the product data sheet or APC support resources specific to your SKU or UPC in APC/Schneider Electric documentation.