APC by Schneider Electric Seismic Kit for 600mm Symmetra PX Battery Cabinets


Price:
Sale price$247.25

Description

In data centers, reliability starts with protection—for power systems, network gear, and the cabinets that house them. The APC by Schneider Electric Seismic Kit for 600mm Symmetra PX Battery Cabinets is purpose-built to reinforce these critical assets against seismic activity, ensuring your Symmetra PX battery cabinets stay securely in place, cables remain intact, and service continuity is preserved when it matters most. This seismic kit is engineered to integrate seamlessly with APC’s 600mm Symmetra PX configurations, giving IT and facilities teams a robust, code-conscious solution that minimizes risk, reduces downtime, and supports ongoing performance in environments ranging from enterprise data centers to edge deployments. By combining rugged construction, straightforward installation, and compatibility with APC’s modular power protection ecosystem, the kit helps you protect investment, uptime, and the integrity of your power protection chain.

  • Engineered seismic reinforcement for 600mm Symmetra PX Battery Cabinets, delivering stable, displacement-resistant support during earthquakes and aftershocks to safeguard critical uptime and maintain orderly cable paths.
  • Includes complete mounting hardware, rugged steel brackets, and a comprehensive installation guide, enabling a quick, tool-efficient setup that minimizes cabinet downtime during swaps or upgrades.
  • Rugged, corrosion-resistant construction with a durable powder-coated finish designed for demanding data-center environments, resisting impact, humidity, and routine maintenance handling over many years of service.
  • Designed to integrate with APC Symmetra PX energy protection modules and standard 19-inch rack systems, allowing secure anchoring to structural supports and maintaining alignment with adjacent cabinets in dense layouts.
  • Helps protect critical loads and reduce risk of cable strain, connector wear, and partial disconnections by preventing cabinet tipping and unwanted movement during seismic events, thereby supporting consistent power protection performance.

Technical Details of APC by Schneider Electric Seismic Kit for 600mm Symmetra PX Battery Cabinets

  • Compatibility: 600mm Symmetra PX Battery Cabinets
  • Material: Steel brackets with a corrosion-resistant, powder-coated finish suitable for data-center environments
  • Finish: Durable powder coat designed to withstand frequent kick-off vibrations, cleaning cycles, and routine maintenance touches
  • Contents: Brackets, mounting hardware, and installation guide included for straightforward commissioning
  • Performance: Provides enhanced stability and restraint for cabinets during seismic activity, helping to maintain alignment and reduce movement-induced risks
  • Mounting: Compatible with standard 19-inch racks and APC Symmetra PX configurations, with mounting points positioned for reliable attachment without obstructing doors or cable management
  • Warranty: Limited warranty per APC Schneider Electric terms, covering manufacturing defects and hardware integrity under normal use

How to Install APC Seismic Kit for 600mm Symmetra PX Cabinets

Installing the Seismic Kit is a practical, repeatable process designed to minimize downtime while maximizing protection for your power protection infrastructure. Before you begin, confirm you have the correct kit for your cabinet model and have access to common tools such as a screwdriver, torque wrench, and a level. Adhering to best practices during installation helps ensure performance reliability and extends the life of both the cabinet and its power components.

Step 1: Plan and verify. Inspect the cabinet and surrounding space to confirm there is unobstructed access for bracket placement and for the installation hardware to engage properly. Check that the floor and rack structure meet the required load-bearing capabilities and that no cabling or cooling components are blocked by the seismic brackets once installed.

Step 2: Position the brackets. Place the seismic brackets at the manufacturer-recommended locations on the cabinet chassis. Align the bracket holes with existing mounting points or with the kit’s specified pre-drilled holes. Use a level to ensure the brackets are vertically aligned to promote even load distribution across the cabinet during vibrations.

Step 3: Secure the brackets to the cabinet. Insert the supplied fasteners through the brackets and into the chassis or frame. Tighten to the recommended torque using the appropriate driver. Avoid over-tightening, which can deform mounting points or affect the structural integrity of the cabinet frame.

Step 4: Anchor to the structure. Depending on the kit contents and your facility design, secure the brackets to structural anchors on the floor or to reinforced rack rails. Use the included hardware to ensure a solid, non-slip connection that resists lateral movement and preserves cabinet alignment during seismic events.

Step 5: Verify clearance and function. After installation, re-check all fasteners for snugness and confirm there is no interference with cabinet doors, cable trays, or airflow paths. Confirm that the installation does not impede access for maintenance and that all adjacent cabinets remain aligned. If your site requires it, perform a controlled vibration check following local safety guidelines to validate the system’s stability under simulated conditions.

Step 6: Document and maintain. Record the installation details in your facility’s asset management logs and schedule periodic rechecks as part of routine infrastructure maintenance. Regular inspections help ensure performance consistency over the cabinet’s lifecycle and help catch any loosening before it becomes an issue.

Frequently asked questions

  • Q: What is the APC Seismic Kit for 600mm Symmetra PX Cabinets? A: It is a dedicated mounting and bracing solution designed to stabilize 600mm-deep Symmetra PX battery cabinets during seismic events, reducing cabinet tipping, minimizing movement, and protecting connected power protection equipment.

  • Q: Is this kit compatible with other APC cabinet models or depths? A: The kit is specifically engineered for 600mm-deep Symmetra PX cabinets. For other depths or APC systems, refer to Schneider Electric’s catalog of seismic accessories to find the appropriate kit designed for those configurations.

  • Q: Can I install the kit myself? A: Yes. The installation is designed to be straightforward with common tools. A qualified technician or facilities professional can perform the installation, especially in complex environments or where additional structural considerations exist.

  • Q: What should I check after installation? A: Inspect bracket alignment, confirm fasteners are tightened to the specified torque, and verify that none of the cables, vents, or access doors are obstructed. Schedule periodic rechecks as part of standard maintenance practices.

  • Q: Does the kit meet specific seismic standards? A: The kit is designed to meet general industry best practices for seismic bracing in data-center environments. For exact standard certifications or documentation, consult the product documentation or Schneider Electric support resources.