Description
APC by Schneider Electric Smart-UPS 1500VA LCD RM 2U 120V with L5-15P
The APC Smart-UPS 1500VA LCD RM 2U is engineered for IT professionals and network admins who demand uptime, protection, and performance in a compact rack-mount form factor. This line-interactive UPS delivers clean, reliable, pure sine wave power to critical equipment during outages and brownouts, helping servers, storage devices, network gear, and telecom hardware stay online when it matters most. With a sleek front-panel LCD for at-a-glance status, robust battery protection, and straightforward integration into standard 19-inch racks, this unit combines enterprise-grade reliability with easy deployment in data centers, server rooms, and remote office environments.
- Powerful protection for critical gear: The 1500VA capacity translates to approximately 900 watts of continuous output, enough to safeguard essential servers, switches, routers, NAS devices, and other frontline IT equipment. Its pure sine wave output ensures clean, stable power delivery to sensitive electronics, minimizing the risk of data corruption, unexpected reboots, and hardware wear during voltage fluctuations. The line-interactive topology with automatic voltage regulation (AVR) boosts or buck surpassing fluctuations, allowing you to preserve battery runtime for longer outages and avoid battery wear from minor swings.
- Efficient rack-mount design with front LCD: This 2U rack-mount UPS is purpose-built to fit standard 19-inch racks, enabling denser, neater IT environments. The front-panel LCD provides real-time readings of input voltage, load, battery condition, runtime estimates, and alarm status. This intuitive interface makes routine monitoring quick and damage-free, reducing the need for external hardware or software just to understand the UPS’s health. It also offers easy navigation through settings without requiring a computer connection.
- Comprehensive outlets and practical connectivity: Outfitted with six NEMA 5-15R outlets, the UPS distributes protected power to multiple devices while preserving a single, convenient power input through the L5-15P plug. This arrangement simplifies integration with regional power standards and minimizes cable clutter in the rack. In addition to the outlets, USB and serial communication ports enable safe, orderly shutdowns and status reporting to workstations or servers, ensuring graceful recovery during outages. Network-grade protection features help guard against surges and spikes that could travel through Ethernet or serial lines.
- Reliable battery and serviceability for long-term uptime: The Smart-UPS line uses a maintenance-replaceable battery cartridge designed for straightforward field replacement. The battery chemistry (VRLA) delivers dependable runtime and endurance in fluctuating ambient temperatures. When it’s time for a replacement, the design facilitates quick service to minimize downtime. Combined with automatic self-tests and an audible alerting system, this UPS helps operations teams plan preventive maintenance and avoid surprise failures in production environments.
- Seamless management and compatibility with IT workflows: In addition to the local LCD interface, the unit supports USB and serial connections for safe shutdown and monitoring, and it is compatible with APC PowerChute software for Windows and macOS. For larger deployments, the UPS can be monitored alongside other power infrastructure using standard management tools, enabling centralized visibility, event logging, and automation. This makes the Smart-UPS 1500VA a natural fit for virtualization hosts, hyperconverged stacks, and mixed IT ecosystems that require reliable power continuity with minimal administrative overhead.
Technical Details of APC by Schneider Electric Smart-UPS 1500VA LCD RM 2U 120V with L5-15P
- Capacity: 1500 VA / 900 W (approximate values; actual runtime depends on load).
- Output waveform: Pure Sine Wave, suitable for sensitive electronics and modern servers.
- Input: 120V nominal, NEMA L5-15P input plug.
- Outlets: 6 x NEMA 5-15R (surge-protected, battery-backed where applicable).
- Form factor: 2U rack-mountable chassis designed for standard 19-inch racks.
- Battery: Replaceable VRLA (valve-regulated lead-acid) battery cartridge; field-serviceable for extended lifecycle.
- Display: Front-panel LCD provides real-time status, load, input/output voltage, battery level, and runtime estimates.
- Management interfaces: USB and Serial (DB-9) ports; supports APC PowerChute software for safe shutdown and power management.
- Topology and features: Line-Interactive with AVR (automatic voltage regulation), surge protection, EMI/RFI filtering, and energy-efficient operation.
- Operating environment: Typical operating temperature and humidity ranges suitable for data centers and equipment rooms; designed for continuous operation in controlled spaces.
- Certifications: UL-listed and CE-listed with standard compliance for business environments.
how to install APC by Schneider Electric Smart-UPS 1500VA LCD RM 2U 120V with L5-15P
Installing the Smart-UPS 1500VA is straightforward and designed to minimize disruption to your IT workflow. Follow these steps to set up the unit quickly and safely, ensuring optimal performance and protection for connected devices.
- Select a secure mounting location: Choose a clean, dry, temperature-controlled area within your server rack or equipment room. Ensure there is adequate airflow and clearance around the front and rear of the unit for cooling and easy cabling. Confirm that the rack has compatible rails or mounting kits for a 2U UPS with front access.
- Mount the UPS in the rack: Attach the unit to the rack using the provided rails or mounting hardware. Align with the center of gravity for stability and connect the chassis securely to prevent vibration or movement during maintenance or power events.
- Connect power and outlets: Plug the L5-15P input cord into a dedicated 120V circuit that can handle the intended load. Connect powered devices (servers, switches, storage devices, and network appliances) to the six NEMA 5-15R outlets on the front panel. Route cables to minimize clutter and ensure easy access for service or replacement.
- Initial startup and self-test: Turn on the UPS using the power switch. The LCD will illuminate, presenting voltage, load, and battery status. Run an initial self-test from the LCD menu to verify battery health and overall operation. If the unit reports a fault, refer to the manual for troubleshooting steps or contact support.
- Configure power management: Install APC PowerChute software on a connected computer (Windows or macOS) if you require automated shutdowns, event alerts, and detailed power reports. Configure shutdown policies, notification thresholds, and scheduled self-tests to align with your IT maintenance windows. For environments without a dedicated management server, rely on the USB/Serial interface for graceful shutdowns of connected servers and workstations.
- Set up monitoring and maintenance reminders: Use the LCD or PowerChute to track runtime, battery health, and audible alarms. Schedule routine battery tests and consider a preventive replacement plan based on usage patterns and manufacturer recommendations. Maintain clear labeling of all cables to simplify future upgrades or servicing.
Frequently asked questions
-
Q: What kind of devices is the APC Smart-UPS 1500VA ideal for protecting?
A: It’s well-suited for small data centers, rack-mounted server ecosystems, network switches, routers, NAS devices, hyperconverged nodes, and telecommunications gear that require clean, reliable power and graceful shutdowns during outages. -
Q: Does the UPS provide a pure sine wave output?
A: Yes. The unit delivers a pure sine wave, which is essential for maintaining compatibility with modern servers and sensitive electronics, reducing the risk of shutdowns or data corruption during power events. -
Q: How do I monitor and manage the UPS?
A: You can monitor via the front LCD, and connect to a computer using USB or Serial for safe shutdowns. APC PowerChute software offers extended power management, event logging, and notification options for Windows and macOS environments. -
Q: Can I replace the battery myself?
A: The UPS uses a replaceable VRLA battery cartridge designed for field service. When the battery reaches end-of-life, you can typically replace it with the appropriate cartridge following the manual’s instructions, minimizing downtime and extending the life of the unit. -
Q: What is the typical runtime, and how does load affect it?
A: Runtime is primarily a function of load and battery health. At lower loads, you’ll typically experience longer runtimes, while higher loads shorten the duration. For precise runtimes, consult the APC runtime charts and use actual load calculations based on your connected devices. -
Q: Is it suitable for 24/7 operation in a data center?
A: Yes, the Smart-UPS 1500VA is designed for continuous operation in controlled data-center or server-room environments, with proper cooling, regular maintenance, and periodic battery checks to maintain reliability over time.
Customer reviews
Showing - Of Reviews