Description
The APC by Schneider Electric Smart-UPS 1500VA Rack-Mountable UPS is the dependable backbone IT professionals rely on to protect servers, storage, and networking gear. Engineered for uptime-critical environments, this 2U rack-mountable unit delivers substantial backup power, clean, reliable output, and intelligent management in a compact footprint designed to fit standard 19-inch racks. With a robust 1500 VA (approximately 900 W) capacity, it provides ample reserve power to ride out outages, maintain essential connectivity, and prevent data loss during power disruptions. This makes it an ideal choice for small to mid-size data centers, IT closets, and edge deployments where space is at a premium but uptime cannot be compromised.
- High-capacity 1500 VA / ~900 W backup power to protect mid-range servers, storage arrays, and network gear during outages and brownouts.
- Line-Interactive topology with automatic voltage regulation (AVR) to correct minor power fluctuations without draining the battery, extending runtime and battery life.
- Pure sine wave output, including when on battery, to ensure compatibility with sensitive equipment and to prevent data corruption or unexpected reboots.
- Space-saving 2U rack-mount design that fits neatly in standard 19-inch racks, improving cable management, airflow, and overall data-center organization.
- Comprehensive management and protection through APC PowerChute and integrated monitoring, enabling graceful shutdowns, alerts, and energy efficiency for busy IT environments.
Technical Details of APC by Schneider Electric Smart-UPS 1500VA Rack-Mountable UPS
- Capacity: 1500 VA / approximately 900 W, providing substantial backup power for mid-range server and network deployments while balancing efficiency and cost.
- Topology: Line-Interactive, offering automatic voltage regulation (AVR) to compensate for minor brownouts and overvoltages without drawing from the battery, which extends runtime and battery life during routine power fluctuations.
- Output: Pure sine wave output on battery for sensitive equipment and smooth operation of connected devices.
- Input: NEMA 5-15P standard input plug compatible with common 120 V outlets.
- Outlets: Six NEMA 5-15R outlets to provide battery-backed protection for multiple critical devices from a single unit.
- Form factor: 2U rack-mount chassis designed for standard 19-inch racks, enabling clean integration into data centers and IT closets.
- Management: Integrates with APC PowerChute and other enterprise management tools to monitor power usage, receive alerts, and enable graceful shutdowns to minimize data loss during outages.
How to install APC by Schneider Electric Smart-UPS 1500VA Rack-Mountable UPS
- Prepare the installation area: ensure the rack space is clear, properly ventilated, and has adequate clearance for cooling and cable management around the UPS.
- Mount the UPS in the rack: use the provided rails or mounting kit to secure the 2U chassis into a standard 19-inch rack. Align the unit to avoid interference with doors or other equipment, and tighten all mounting hardware.
- Connect input power: plug the NEMA 5-15P input cord into a dedicated 120 V AC power outlet. Ensure the wall outlet or power strip feeding the UPS can handle the load and provides stable power.
- Protect critical devices: connect servers, storage devices, switches, routers, and other essential equipment to the six NEMA 5-15R outlets on the UPS. Distribute critical devices across outlets to maximize uptime during a prolonged outage.
- Power up and verify: switch on the UPS and check the local status indicators or LCD readout (if available) to confirm normal operation. Review voltage, load, and battery status to ensure everything is within expected ranges.
- Install management software: if you plan to monitor and manage power events centrally, install APC PowerChute on a connected server or workstation and configure it to monitor the UPS and perform graceful shutdowns when needed.
- Run a self-test and perform a simulated outage: initiate a self-test (if supported) and, with proper safeguards, perform a controlled outage test to verify that protected devices automatically shut down safely and that the UPS responds correctly to power loss.
- Documentation and ongoing maintenance: keep the user manual accessible for configuration options, firmware updates, and battery replacement guidance. Schedule periodic health checks and battery replacement per the maintenance plan.
Frequently asked questions
- What is the capacity of the APC Smart-UPS 1500VA Rack-Mountable UPS? It is rated at 1500 VA / approximately 900 W, providing substantial backup power for mid-range server and network deployments while balancing efficiency and cost.
- What equipment is suitable to connect to this UPS? Ideal for servers, storage arrays, switches, routers, and other critical IT devices that require uninterrupted power during outages.
- Does it deliver clean power? Yes. The UPS provides pure sine wave output, including while running on battery, to ensure stable and safe operation for sensitive equipment.
- How can I manage power events and perform graceful shutdowns? The UPS integrates with APC PowerChute and other management tools to monitor power usage, receive alerts, and execute graceful shutdowns to protect data and hardware.
- Will it fit in a standard data-center rack? Yes. The unit’s 2U rack-mount design is tailored for standard 19-inch racks, helping you optimize space, cabling, and airflow in data centers and IT rooms.
Customer reviews