Description
APC by Schneider Electric Smart-UPS 3000 VA Tower/Rack Mountable UPS
The APC by Schneider Electric Smart-UPS 3000 VA Tower/Rack Mountable UPS is a cornerstone of dependable power protection for IT networks, servers, storage systems, and critical networking gear. Designed for data centers, server rooms, and sophisticated home labs, this uninterruptible power supply (UPS) delivers clean, reliable power with professional-grade management features. It shields your equipment from outages, brownouts, spikes, and other electrical disturbances while preserving data integrity and minimizing downtime. With flexible deployment options, scalable runtime, and intelligent battery management, the Smart-UPS 3000 VA is engineered to maximize uptime and simplify administration in demanding environments.
- Uninterruptible, clean power for critical equipment: The Smart-UPS 3000 VA provides robust protection for servers, switches, storage devices, and network devices. Its double-conversion online topology continuously converts incoming AC power to DC and back to simulated sine-wave AC, ensuring a pristine voltage supply even during input disturbances. This seamless transition prevents data corruption, safeguards storage arrays, and maintains application continuity during outages.
- Tower or rack-mount versatility: This UPS is engineered for flexibility, offering both a compact tower form factor and a rack-mountable option. Install it in standard 2U rack spaces or place it as a standalone tower in a data closet or edge environment. The adaptable design simplifies cabling, airflow, and maintenance while supporting scalable deployments across growing networks.
- Comprehensive management and monitoring: Out-of-the-box USB and Serial interfaces enable straightforward local management. For advanced monitoring, optional Network Management Cards (NMC) and PowerChute software integration provide remote visibility, live event alerts, and graceful shutdown capabilities. It supports SNMP/Web-based monitoring and can be integrated with existing IT management ecosystems to automate power-down sequences and preserve business continuity.
- Battery efficiency and extendable runtime: The UPS uses maintenance-free, hot-swappable, reliable VRLA batteries. Battery packs are designed for easy replacement without interrupting connected devices, and runtime scales with load and additional battery options. Automatic Battery Condition checks and smart battery management extend service life, while load-aware runtime planning helps you budget for expected outages and planned maintenance windows.
- Smart protection features and energy-aware operation: Automatic Voltage Regulation (AVR) stabilizes incoming voltages, reducing battery wear during minor sags or surges. The system includes surge protection, robust wattage handling, and an intuitive front-panel LCD and indicators for quick status checks. When energy efficiency matters, ECO mode and other intelligent controls optimize overall power use without compromising uptime.
Technical Details of APC by Schneider Electric Smart-UPS 3000 VA Tower/Rack Mountable UPS
- Capacity: 3000 VA / 2700 W, designed to support multiple servers, switches, storage devices, and networking gear in a single system or distributed mini-rack configurations.
- Topology: Double-Conversion Online (on-line) UPS delivers continuous, clean power with minimal transfer time in the event of a disturbance.
- Input voltage: 120/230 VAC auto-sensing (configurable by model and region) with a broad input range to tolerate voltage fluctuations.
- Output voltage: Configurable to 120 VAC or 230 VAC with ±5% regulation to ensure compatibility with sensitive equipment and precise power delivery.
- Form factor: Tower or 2U rack-mountable chassis, enabling flexible placement in data centers, labs, or office environments.
- Management options: USB and Serial connectors for local management; optional Network Management Card (APC/NMC) for remote monitoring, SNMP, and web access.
- Display and indicators: Front-panel LCD status display with intuitive icons and real-time readouts for load, battery, and temperature.
- Battery system: Hot-swappable, maintenance-free sealed lead-acid batteries; battery replacement can be done without disconnecting critical loads.
- Runtime and scalability: Runtimes vary by load; support for battery expansion and monitor-driven shutdown to fit web-scale or small-business environments.
- Protection features: AVR (boost and trim), surge protection, short-circuit protection, overload protection, and alarm management for proactive fault handling.
- Environmental operating range: 0–40°C (32–104°F) and up to 95% relative humidity (non-condensing) for flexible deployment in typical data centers and office spaces.
- Certifications and safety: Compliant with global safety and electromagnetic compatibility standards to meet industry requirements for IT infrastructure equipment.
- Warranty and support: Backed by Schenider Electric’s warranty programs; extended service options are available through authorized partners for mission-critical deployments.
how to install APC by Schneider Electric Smart-UPS 3000 VA Tower/Rack Mountable UPS
Installing the Smart-UPS 3000 VA is a straightforward process designed to minimize downtime and protect your IT assets from the start. Start by planning your deployment: decide whether you will place the unit in a raised rack, a dedicated equipment closet, or a protected room with adequate ventilation and clear airflow around the UPS and mounted equipment. Ensure the environment is free from excess dust, moisture, and direct heat sources, and verify that the rack or stand has sufficient weight capacity to support the UPS plus connected devices.
1) Position and secure: Transport the UPS carefully and place it in the chosen location. If using the rack-mount option, install the device securely into a 2U rack space using the included mounting rails and hardware. If using as a tower, position the unit on a stable, level surface with proper clearance for intake and exhaust airflow. Avoid enclosing the UPS in tight spaces where heat can build up.
2) Connect the batteries: Before connecting any equipment, connect or install the internal battery cartridges according to the user manual. If the UPS ships with batteries already installed, allow a brief cooldown and perform a self-test once initial power is supplied. Ensure any external battery packs (if applicable) are properly attached and recognized by the unit’s management interface.
3) Power connections: Connect the UPS to a grounded wall outlet using the supplied power cable. Then connect your critical devices to the UPS output outlets, ensuring total connected load remains within the 2700 W rating. If you expect peak loads or startup surges, distribute devices across multiple outlets or banks to avoid overloading a single outlet group.
4) Network and management setup: If you plan to monitor and manage the UPS remotely, attach a USB or Serial connection to a management host and install the PowerChute or compatible management software. If you are using a Network Management Card, install it in the proper slot and assign an IP address for remote access and integration with your IT monitoring systems.
5) Configure settings and perform a self-test: Use the front-panel LCD or management software to configure the desired settings (output voltage, language, alarms, shutdown behavior). Run a self-test to verify battery health and overall operation. Review load, battery, and temperature readings to ensure everything stays within safe operating ranges.
6) Documentation and routine maintenance: Record your configuration details, serial numbers, and warranty information. Schedule regular self-tests and battery health checks to proactively catch degraded batteries before they impact uptime. Keep spare batteries or replacement packs on hand if your environment demands extended runtimes or frequent power events.
Frequently asked questions
- What equipment can I protect with the APC Smart-UPS 3000 VA? It is designed to safeguard critical IT infrastructure, including servers, switches, storage systems, and network devices, as well as other electronics that require clean, reliable power.
- Can I mount this UPS in a rack? Yes. The unit supports a tower configuration or a 2U rack-mount installation, making it suitable for data centers, server rooms, or edge deployments.
- What about battery replacement and runtime? The UPS uses hot-swappable, maintenance-free batteries. Runtime depends on the connected load; higher loads consume more runtime, while lighter loads extend it. External battery packs can further extend runtime in larger deployments.
- How do I manage and monitor the UPS remotely? Use the USB or Serial interface for local management, and attach an optional Network Management Card for remote monitoring, SNMP, and web access. PowerChute software provides graceful shutdown and power event reporting.
- Is AVR available and does the UPS support efficient operation? Yes. Automatic Voltage Regulation helps stabilize voltage without drawing on the battery during mild sags, and energy-efficient modes (like ECO mode) help reduce power consumption without compromising uptime.
- What maintenance is required? Regular self-tests, battery health checks, and firmware or software updates (when applicable) are recommended to ensure ongoing reliability and compatibility with your IT environment.
Customer reviews
Showing - Of Reviews