Description
APC by Schneider Electric Smart-UPS 3000VA RM 2U LCD 100V
Power reliability is non-negotiable in today’s data-driven environments. The APC by Schneider Electric Smart-UPS 3000VA RM 2U LCD 100V is designed to protect servers, storage, and networks with award-winning, world-renowned reliability. This online, double-conversion UPS delivers pristine, network-grade power for critical equipment, ensuring your data stays safe, your uptime stays high, and your IT operations stay smooth—even when power problems strike. Built to endure demanding business environments, the Smart-UPS RM (Rack-Mount) is a trusted backbone for mid-sized data centers, broadcast suites, and IT closets that demand uninterrupted performance, accurate voltage regulation, and proactive power management.
- Online, double-conversion power protection keeps sensitive equipment safe from outages, sags, surges, and electrical noise by converting incoming power to clean, uninterrupted output. This topology delivers pure sine-wave power with minimal transfer times, ensuring compatibility with modern servers, storage arrays, and networking gear while minimizing risk of data corruption during brownouts.
- Rack-mount design for space-efficient installation at 2U height makes it ideal for standard 19-inch racks in data centers and IT rooms. Compact yet mighty, it fits snugly in tight spaces without compromising cooling, accessibility, or serviceability. Its sturdy construction and hot-swappable batteries simplify maintenance without taking equipment offline.
- Large LCD interface and intuitive management—the onboard LCD provides real-time status, load, input/output voltage, battery condition, and event history at a glance. This user-friendly display reduces guesswork during deployment and ongoing maintenance, while LED indicators quick-check health at a glance. You can monitor the UPS locally and plan maintenance windows with confidence.
- 100V input and reliable runtime flexibility designed for 100V national power grids, with auto-sensing, broad compatibility, and smart battery management. The Smart-UPS scales with your IT environment, offering modular runtime options and easy expansion to cover spikes in demand as your rack grows.
- Comprehensive protection for critical workloads from power anomalies thanks to automatic voltage regulation (AVR), surge protection, and a robust battery system. With network management options, shutdown software, and remote monitoring, IT teams can safeguard uptime, protect data integrity, and optimize operating costs over the life of the unit.
Technical Details of APC by Schneider Electric Smart-UPS 3000VA RM 2U LCD 100V
- Power rating: 3000 VA / 2700 W (typical) online, double-conversion UPS designed for critical IT loads.
- Topology: Online (double conversion) with pure sine-wave output for clean, consistent power to sensitive equipment.
- Output waveform: Pure sine wave, ensuring compatibility with modern servers and storage devices that require precise power characteristics.
- Input voltage: 100 V nominal (auto-sensing to accommodate minor utility variations); 50/60 Hz auto-detection for broad regional compatibility.
- Output voltage: 100 V nominal to match connected equipment and local power standards.
- Form factor: 2U rack-mountable design for space-efficient deployment in standard 19-inch racks.
- Batteries: Hot-swappable, user-replaceable sealed lead-acid battery system to minimize downtime during battery swaps.
- Management and sensing: LCD interface for local monitoring; USB and serial communications as standard; optional Network Management Card (not included) for advanced remote management and SNMP integration.
- Protection and features: Automatic Voltage Regulation (AVR) to stabilize voltage without battery drain, surge and short-circuit protection, self-test diagnostics, and audible/visual alarms for critical events.
- Runtime considerations: Runtime varies with load and battery health; the unit is designed to deliver graceful shutdown and transfer to battery power during outages, with scalable runtime options through external battery modules where supported.
- Operating environment: Optimized for data centers and IT rooms with consideration for ambient temperature, humidity, and ventilation to maximize battery life and performance.
- Certifications: Built to meet industry standards for safety and power reliability; compatible with common enterprise software for graceful shutdown and power management.
How to install APC by Schneider Electric Smart-UPS 3000VA RM 2U LCD 100V
- Plan the rack placement: Choose a stable, well-ventilated rack bay with enough clearance for heat dissipation and maintenance access. Confirm that the 2U height will fit in your rack configuration and that the UPS will not obstruct cable management or airflow.
- Mount the unit in the rack: Use the included mounting rails or hardware to secure the UPS in the rack. Tighten screws evenly to prevent vibration, and ensure the unit is level for proper battery connection and venting.
- Connect the input power: Attach the appropriate input power cord to the UPS input and connect to a dedicated circuit that matches the 100 V nominal rating. Avoid overloading the circuit and follow electrical codes for safe installation.
- Connect devices and outlets: Plug servers, storage devices, and networking gear into the UPS’ dedicated output outlets. Do not exceed the rated load to maintain optimal performance and battery life; prefer outlets with independent protection for critical gear.
- Configure management options: If you plan to manage the UPS remotely, attach the USB or serial cable to a management computer and install PowerChute or compatible software. Consider adding a Network Management Card for SNMP-based monitoring and remote shutdown scheduling.
- Power up and initialize: Turn on the UPS, verify the LCD displays normal status, check battery health, and run a self-test as recommended by the user manual. Confirm that connected equipment switches to battery power seamlessly during a simulated outage to validate protection.
- Schedule maintenance and monitor: Set up event alerts, runtime expectations, and automatic shutdown policies. Regularly review the LCD readouts for load, battery health, and input/output conditions, and perform periodic battery tests to maintain reliability.
Frequently asked questions
- Q: What makes the APC Smart-UPS 3000VA RM 2U LCD 100V different from other UPS models?
- A: It delivers online, double-conversion protection with pure sine-wave output, a compact 2U rack-mount form factor, an intuitive LCD interface, and robust battery management designed for servers, storage, and networks that demand consistent, clean power.
- Q: Is this UPS suitable for 100V markets?
- A: Yes. It is designed for 100 V nominal input/output, with auto-sensing capabilities to accommodate minor utility variations while protecting connected equipment.
- Q: Can I monitor and manage the UPS remotely?
- A: Yes. The basic configuration includes USB/serial communication for local management, and an optional Network Management Card enables remote monitoring, SNMP integration, and centralized power management.
- Q: Are the batteries replaceable?
- A: Yes. The UPS uses hot-swappable, user-replaceable sealed lead-acid batteries to minimize downtime during battery maintenance or replacement.
- Q: How do I ensure the longest possible life from this UPS?
- A: Maintain proper ambient conditions, perform regular battery tests, avoid overloading the UPS, and replace batteries per the manufacturer’s recommended schedule to maintain peak performance and reliability.
- Q: Will this UPS protect sensitive networking gear in addition to servers?
- A: Absolutely. Its pure sine-wave output, voltage regulation, and surge protection make it suitable for a variety of critical IT devices, including routers, switches, NAS devices, and small-scale storage arrays in addition to servers.
Customer reviews
Showing - Of Reviews