APC by Schneider Electric Smart-UPS SMX1500RMI2U 1500 VA Tower/Rack Mountable UPS


Price:
Sale price$1,615.44

Description

APC by Schneider Electric Smart-UPS SMX1500RMI2U 1500 VA Tower/Rack Mountable UPS

Meet the APC Smart-UPS SMX1500RMI2U, a high-performance uninterruptible power supply designed to protect critical data and maintain uptime in dynamic IT environments. This versatile unit blends a traditional tower form with a rack-optimized, convertible design, enabling seamless deployment in small offices, data closets, or larger data centers. Engineered to deliver reliable, network-grade power, the SMX1500RMI2U safeguards servers, storage devices, network gear, and workstations from outages, surges, and voltage fluctuations while minimizing the risk of data loss or corruption. With PowerChute management software included, IT administrators gain the ability to perform safe shutdowns, monitor UPS health, and implement proactive power management—making this UPS a smart, scalable backbone for modern infrastructure and a key component of a resilient IT strategy.

  • High-capacity protection for essential equipment: 1500 VA / 900 W output provides ample headroom to support servers, network switches, NAS devices, and workstations. This capacity translates into meaningful runtime during outages, enabling critical applications to close gracefully and data to be saved without abrupt interruptions.
  • Flexible form factor for any environment: Convertible design supports traditional tower placement or 2U rack installation, letting you adapt to space constraints in offices, data closets, or server rooms. The flexibility simplifies deployment, reduces clutter, and preserves valuable floor space while maintaining optimal airflow for cooling.
  • Intelligent management and monitoring: PowerChute software enables safe system shutdown, energy usage reporting, event logging, and proactive alerts. USB and serial interfaces provide reliable local control and integration with existing IT workflows and monitoring tools, helping administrators optimize power utilization across the network.
  • Top-tier power quality with AVR: Automatic Voltage Regulation stabilizes fluctuating mains power, protecting sensitive electronics from brownouts and overvoltages. This results in cleaner output to connected devices and less unnecessary battery wear, preserving battery life for true outages.
  • Reliability, serviceability, and lifecycle support: Hot-swappable, replaceable battery cartridge lowers downtime during routine maintenance. Clear status indicators and a robust build deliver long-term reliability, while straightforward maintenance minimizes seizure of operations during battery replacement or firmware updates.

Technical Details of APC by Schneider Electric Smart-UPS SMX1500RMI2U 1500 VA Tower/Rack Mountable UPS

  • Model: SMX1500RMI2U
  • Power rating: 1500 VA / 900 W
  • Form factor: Tower and 2U rack-mountable chassis for flexible deployment in offices, closets, or data centers
  • Output waveform: Pure sine wave on battery to ensure clean, stable power for sensitive devices
  • Input voltage: 120 VAC nominal (with automatic sensing and wide input range to accommodate North American power grids)
  • Voltage regulation: Automatic Voltage Regulation (AVR) to correct minor power fluctuations without unnecessary battery use
  • Protection and reliability: Overload protection, surge suppression, and a replaceable, hot-swappable battery cartridge (RBC) for extended service life
  • Management interfaces: USB and RS-232 serial ports for local management; compatible with PowerChute software and supports optional network management cards
  • Monitoring and diagnostics: Live load and battery status indicators, runtime estimates, and a clear LCD/status panel for quick assessment

How to install APC by Schneider Electric Smart-UPS SMX1500RMI2U

  • Choose a suitable location with adequate ventilation and access to a dedicated 120 VAC outlet; ensure the installation area allows for proper airflow around the unit.
  • Decide between tower placement or rack-mount installation; if rack-mounting, use the included rails and hardware, align the chassis, and secure it firmly to the rack rails.
  • Connect critical devices to the UPS outlets and connect the management interface (USB or RS-232) to a computer or server to enable monitoring and control.
  • Power the UPS from a dedicated outlet and perform the initial configuration using the LCD panel or PowerChute software, setting voltage thresholds, shutdown policies, and notification preferences to match your environment.
  • Test the system by simulating a power interruption to verify expected runtimes and graceful shutdown behavior; document configuration settings for IT records and future audits.

Frequently asked questions

Q: What systems is the SMX1500RMI2U best suited to protect?

A: It is ideal for servers, network devices (such as switches and routers), storage solutions, and workstations in small to mid-size IT environments where uptime and data integrity are critical. Its 1500 VA capacity and clean sine-wave output provide reliable protection for essential equipment during outages or power irregularities.

Q: Does the unit include software for safe shutdown?

A: Yes. The package includes PowerChute management software, which enables safe automatic shutdown, UPS monitoring, event logging, and energy management compatible with Windows and Linux environments, helping IT teams maintain orderly operations during power events.

Q: Can I rack-mount this UPS?

A: Absolutely. The SMX1500RMI2U ships with rails and is designed as a convertible tower/rack-mountable UPS, giving you the flexibility to mount it in a standard 19-inch rack or leave it as a sturdy tower depending on your available space.

Q: How does the AVR feature help protect my equipment?

A: Automatic Voltage Regulation corrects minor fluctuations in incoming power without requiring battery usage, delivering steadier voltage to connected devices and reducing battery wear while maintaining uptime during momentary surges or sags.

Q: What maintenance is involved with this UPS?

A: Routine checks include verifying firmware and software versions, inspecting battery health indicators, testing the unit during a controlled outage, and replacing the battery cartridge when runtime noticeably declines. Regular monitoring through PowerChute helps anticipate service intervals and minimize downtime.