Description
APC by Schneider Electric Smart-UPS X SMX2200RMLV2U 2200 VA Rack-mountable UPS
In today’s IT environments, downtime is not an option. The APC by Schneider Electric Smart-UPS X SMX2200RMLV2U delivers reliable power protection for your most critical systems, from servers and storage to networking gear and virtualization hosts. Engineered for IT managers and network administrators, this 2U rack-mountable UPS combines robust hardware with smart features that safeguard uptime, optimize workloads, and simplify management. With a front-panel LCD, hot-swappable batteries, and versatile outlet configurations, the SMX2200RMLV2U is designed to keep your business online even when input power fluctuates, surges, or fails entirely. Whether you’re protecting a data center rack, a small enterprise server cabinet, or a dedicated network closet, this UPS provides clean, continuous power and intelligent battery management to extend equipment life and reduce maintenance.
- Power protection you can rely on. The SMX2200RMLV2U delivers 2200 VA / 1980 W of dependable backup power, ensuring servers, switches, routers, storage arrays, and virtualization hosts stay online during outages. With a pure sine wave output and robust AVR (automatic voltage regulation), it maintains stable voltage to critical devices even as input power swings, minimizing the risk of boot failures or data corruption.
- Intelligent monitoring and remote management. An intuitive front-panel LCD provides real-time information on load, battery status, input/output voltages, and runtime estimates. It supports USB and Serial communication for local management, and is compatible with PowerChute software for graceful shutdowns, analytics, and power-event reporting. Optional network management card enables remote monitoring and control over IP.
- Rack-mount-ready with modular battery options. Engineered for server rooms and data closets, the SMX2200RMLV2U fits snugly in standard 19-inch racks as a 2U unit. It offers hot-swappable battery modules, reducing downtime during maintenance and extending life for essential batteries without powering down connected equipment. Front-accessible design makes routine battery service fast and safe.
- Efficient, enterprise-grade performance. With high-efficiency operation and advanced power conditioning, this UPS helps reduce energy costs while protecting connected equipment from power surges, noise, and brownouts. It is suitable for virtualization platforms and critical IT workloads, supporting clean shutdowns, proper sequencing, and consistent performance under load.
- Reliable protection with broad compatibility. The SMX2200RMLV2U is built to withstand demanding environments and works across multiple regions and devices. It supports a wide input voltage range, offers surge protection, short-circuit protection, and overload protection, and is backed by Schneider Electric’s support ecosystem for ongoing reliability and serviceability.
Technical Details of APC by Schneider Electric Smart-UPS X SMX2200RMLV2U 2200 VA Rack-mountable UPS
- Model: SMX2200RMLV2U
- Series: Smart-UPS X
- Capacity: 2200 VA / 1980 W
- Form Factor: 2U Rack-Mountable
- Output Voltage: 120 V or 230 V selectable (depending on regional configuration)
- Output Waveform: Pure Sine Wave
- Input Voltage Range: 176–294 VAC
- Frequency: 50/60 Hz (auto-sensing)
- Automatic Voltage Regulation (AVR): Yes
- Battery Type: Sealed Lead-Acid, Hot-Swappable
- Battery Runtime (approximate): ~12–20 minutes at 50% load (varies with actual load and condition)
- Battery Replacement: Hot-swappable battery modules for quick maintenance
- Communication Ports: USB, Serial; optional Network Management Card for remote monitoring
- Display: Front-panel LCD for status, load, voltage, and runtime
- Management Software: PowerChute SE compatibility; Windows, Linux, VMware support
- Operating Environment: 0–40°C; 0–95% non-condensing humidity
- Certifications: Safety and regulatory approvals appropriate to global deployments
how to install APC by Schneider Electric Smart-UPS X SMX2200RMLV2U
Installing the SMX2200RMLV2U in a rack is straightforward and designed to minimize downtime. Follow these steps to ensure a secure, properly powered setup that delivers reliable uptime:
1) Plan your rack layout. Determine a suitable location with adequate ventilation, easy access to outlets, and clearance for front-panel monitoring. Confirm the rack has a stable mounting surface and that the weight of the UPS plus any attached battery modules fits within the rack’s load rating.
2) Prepare the UPS and battery modules. If you’re including hot-swappable battery packs, ensure they are within reach and ready for connection. Inspect cables to verify there are no visible signs of damage. Have the appropriate rack screws and mounting rails on hand.
3) Mount the unit. Slide the SMX2200RMLV2U into the rack and secure it with the supplied screws. Ensure airflow is not obstructed by cables or adjacent equipment. Leave space in front and rear for cooling and servicing.
4) Connect the battery and load. Attach battery modules if included, following the manufacturer’s connection guidelines. Connect your critical devices to the UPS outlets, prioritizing essential equipment first. Keep nonessential loads on non-battery outlets where possible to maximize uptime during outages.
5) Establish power and communications. Plug the UPS into a dedicated AC circuit. Connect USB and/or Serial cables to a management PC or server for local monitoring. If using a Network Management Card, install it per the card’s instructions and enable IP-based monitoring.
6) Configure the system. Use the front-panel LCD to set region, language, input/output settings, and alarm thresholds. Calibrate the batteries if prompted, and run the built-in self-test to verify correct operation. For environments with virtualization, install PowerChute SE and configure shutdown policies to protect virtual machines and databases during outages.
7)Test and monitor. Initiate a controlled test to confirm graceful shutdown of operating systems and to validate runtime estimates. Monitor the UPS over time for battery health, load trends, and event logs. Establish alerting rules so IT staff are notified of abnormal conditions before they impact workloads.
8) Maintain and review. Schedule regular battery health checks and firmware updates if provided by Schneider Electric. Periodically review runtime forecasts and adjust connected loads to optimize uptime during longer outages.
Frequently asked questions
- What does 2200 VA / 1980 W mean for my equipment? The 2200 VA rating represents the apparent power capacity, while 1980 W is the real power your connected devices can draw. This UPS is designed to support servers, storage, and network equipment with headroom for surge currents and peak loads, giving you a stable and reliable power path during outages or disturbances.
- Are the batteries hot-swappable? Yes. The SMX2200RMLV2U uses hot-swappable battery modules, allowing you to replace or upgrade batteries without powering down the connected equipment, minimizing downtime during maintenance or battery aging.
- Can I monitor and manage it remotely? Absolutely. It includes USB and Serial connections for local management and supports an optional Network Management Card for remote monitoring and SNMP-based alerting. PowerChute SE software facilitates graceful shutdowns, event logging, and power-management policies across servers and workstations.
- Is this UPS suitable for virtualization environments? Yes. The clean, continuous power and reliable runtime preservation make it well-suited for virtualization hosts (e.g., VMware, Hyper-V, and KVM) and storage arrays. It helps protect running VMs, prevents data loss during outages, and supports orderly VM shutdowns when power is lost.
- What kind of outlets and power conditioning does it provide? The SMX2200RMLV2U delivers surge protection, short-circuit protection, and voltage regulation to connected devices. It offers a mix of battery-backed outlets for critical equipment and surge-only outlets for non-essential devices, depending on region and configuration, ensuring that essential gear stays powered during an outage.