Description
APC Leak Sensor - 20 ft (6.1 m) – Advanced Leak Detection for Row Cooling Systems
The APC Leak Sensor (20 ft / 6.1 m) is engineered to safeguard row cooling installations and data center environments by providing precise, timely detection of water and other conductive liquids. Designed for reliability in demanding facilities, this sensor helps prevent costly downtime and equipment damage by delivering early warnings that empower IT and facilities teams to act quickly. With an extended 20-foot monitoring cable, flexible installation options across rows, racks, and under raised floors, and seamless integration with APC monitoring ecosystems, this sensor becomes a critical component of any active cooling strategy. Whether you’re outfitting a new data hall or upgrading an existing setup, the APC Leak Sensor delivers peace of mind through robust sensing, clear alerts, and easy maintenance.
- Extended monitoring reach: A 20 ft (6.1 m) sensor cable provides wide coverage along row cooling infrastructure, enabling you to place detection points exactly where leaks are most likely to occur without compromising placement or accessibility.
- Accurate leak detection: The moisture/leak sensor delivers rapid and reliable detection of water and other conductive liquids, triggering alerts to prevent water damage, corrosion, and downtime in mission-critical environments.
- Seamless APC integration: Designed to work with APC monitoring interfaces and compatible cooling systems, the sensor feeds real-time status updates into your existing management software, raising alarms and guiding response workflows.
- Rugged, data-center-ready design: Built for reliability in demanding environments, the sensor features industrial-grade construction with stable performance under typical data center conditions, ensuring consistent monitoring over time.
- Flexible installation and maintenance: The sensor’s mounting options and cable routing capabilities allow installation in tight spaces around row cooling units, with straightforward maintenance and test procedures to keep detection consistent.
Technical Details of APC Leak Sensor - 20 ft (6.1 m)
- Cable length: 20 ft (6.1 m)
- Sensor type: Moisture/leak detection sensor with alert signaling
- Detection capability: Detects presence of conductive liquids to trigger alarms
- Physical design: Industrial-grade sensor housing suitable for data-center environments
- Compatibility: Works with APC monitoring systems and compatible cooling equipment
- Mounting and routing: Flexible mounting options for rows, racks, and under raised floors
How to install APC Leak Sensor - 20 ft (6.1 m)
- Plan the installation path by identifying high-risk leak points along the row cooling infrastructure, including drain lines, condensate traps, and potential spill zones.
- Uncoil and route the 20 ft cable along the intended path, ensuring the cable remains clear of moving components, hot surfaces, and sources of abrasion. Use appropriate cable ties or clips to secure it neatly.
- Mount the sensor element at the chosen detection location, following manufacturer guidelines for orientation and accessibility. Ensure the sensor is positioned to maximize contact with any liquid that may be present on surfaces or floors.
- Connect the sensor cable to the APC monitoring interface or compatible controller, verifying secure connections and proper cable routing to avoid strain or disconnection during maintenance or cleaning.
- Configure alert thresholds and notification channels within your APC management software or connected subsystem, setting appropriate response actions for detected leaks (e.g., email alert, SNMP trap, or paging).
- Perform a controlled sensor test in accordance with manufacturer recommendations to confirm that the sensor detects a simulated leak and that alerts are properly recorded and transmitted to the monitoring system.
Frequently asked questions
-
Q: What is the purpose of the APC Leak Sensor?
A: It provides early detection of liquid leaks near row cooling equipment to prevent water damage, downtime, and equipment failures by triggering real-time alerts. -
Q: How long is the sensor cable?
A: The sensor cable length is 20 feet (6.1 meters), allowing flexible placement along rows and under raised floors. -
Q: Which systems does it work with?
A: It is designed to integrate with APC monitoring interfaces and compatible cooling equipment, enabling centralized visibility and alerting within your existing data-center management tools. -
Q: How do I test the sensor?
A: Use the manufacturer-approved test procedure to simulate a leak and verify that alerts appear in the APC software, then confirm that notification channels respond as configured. -
Q: Is there a maintenance plan for the sensor?
A: Regular inspections of the sensor and cable, along with periodic test cycles, help ensure continued reliability. Follow your facilities’ maintenance schedule and APC guidelines for best results.